Technical specifications

Width131mm
Height273mm
With control elementYes
Number of HW-interfaces serial TTY0
Number of HW-interfaces industrial Ethernet0
Number of HW-interfaces USB0
Number of HW-interfaces RS-4220
Number of HW-interfaces RS-4851
Number of digital inputs5
Number of analogue outputs2
Depth204mm
With optical interfaceNo
Number of HW-interfaces parallel0
Number of digital outputs2
Supporting protocol for LONNo
Number of HW-interfaces other0
Number of HW-interfaces RS-2320
Power consumption330W
Supporting protocol for INTERBUSNo
Supporting protocol for PROFIBUSYes
Supporting protocol for TCP/IPYes
Number of analogue inputs2
Supporting protocol for ASINo
Supporting protocol for CANYes
Supporting protocol for DeviceNetYes
Supporting protocol for SUCONETNo
Mains voltage500 - 600V
Supporting protocol for INTERBUS-SafetyNo
Relative symmetric net voltage tolerance10%
Number of interfaces PROFINET0
With PC connectionYes
Supporting protocol for Data-HighwayNo
Max. output frequency500Hz
Number of phases output3
Type of converterU converter
Supporting protocol for SERCOSNo
Degree of protection (IP)IP20
Max. output at linear load at rated output voltage11kW
Mains frequency50/60 Hz
Number of phases input3
Application in domestic- and commercial area permittedYes
Application in industrial area permittedYes
Supporting protocol for ModbusYes
Integrated breaking resistanceYes
Supporting protocol for KNXNo
Supporting protocol for other bus systemsYes
4-quadrant operation possibleYes
Relative symmetric net frequency tolerance10%
Max. output at quadratic load at rated output voltage11kW
Supporting protocol for PROFIsafeNo
Supporting protocol for EtherNet/IPYes
Supporting protocol for SafetyBUS pNo
Degree of protection (NEMA)Other
Nominal output current I2N17A
Supporting protocol for DeviceNet SafetyNo
Supporting protocol for AS-Interface Safety at WorkNo
Max. output voltage600V
Supporting protocol for PROFINET CBANo
Supporting protocol for Foundation FieldbusNo
Supporting protocol for PROFINET IOYes
Supporting protocol for BACnetNo

Related products

*VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user

DA1-35017NB-A20C

Main Product Image

Why Register?

  • View wholesale prices with discounts
  • Real-time stock availability
  • Access invoices and dispatch notes
  • Order history and frequently ordered items
  • Exclusive B2B offers

and much more...

Details

  • Low-voltage industrial components
  • Frequency converter =< 1 kV
  • 1 KOM
  • EATON

Technical specifications

Width

131mm

Height

273mm

With control element

Number of HW-interfaces serial TTY

0

Number of HW-interfaces industrial Ethernet

0

Number of HW-interfaces USB

0

Number of HW-interfaces RS-422

0

Number of HW-interfaces RS-485

1

Number of digital inputs

5

Number of analogue outputs

2

Depth

204mm

With optical interface

Number of HW-interfaces parallel

0

Number of digital outputs

2

Supporting protocol for LON

Number of HW-interfaces other

0

Number of HW-interfaces RS-232

0

Power consumption

330W

Supporting protocol for INTERBUS

Supporting protocol for PROFIBUS

Supporting protocol for TCP/IP

Number of analogue inputs

2

Supporting protocol for ASI

Supporting protocol for CAN

Supporting protocol for DeviceNet

Supporting protocol for SUCONET

Mains voltage

500 .. 600V

Supporting protocol for INTERBUS-Safety

Relative symmetric net voltage tolerance

10%

Number of interfaces PROFINET

0

With PC connection

Supporting protocol for Data-Highway

Max. output frequency

500Hz

Number of phases output

3

Type of converter

U converter

Supporting protocol for SERCOS

Degree of protection (IP)

IP20

Max. output at linear load at rated output voltage

11kW

Mains frequency

50/60 Hz

Number of phases input

3

Application in domestic- and commercial area permitted

Application in industrial area permitted

Supporting protocol for Modbus

Integrated breaking resistance

Supporting protocol for KNX

Supporting protocol for other bus systems

4-quadrant operation possible

Relative symmetric net frequency tolerance

10%

Max. output at quadratic load at rated output voltage

11kW

Supporting protocol for PROFIsafe

Supporting protocol for EtherNet/IP

Supporting protocol for SafetyBUS p

Degree of protection (NEMA)

Other

Nominal output current I2N

17A

Supporting protocol for DeviceNet Safety

Supporting protocol for AS-Interface Safety at Work

Max. output voltage

600V

Supporting protocol for PROFINET CBA

Supporting protocol for Foundation Fieldbus

Supporting protocol for PROFINET IO

Supporting protocol for BACnet

Related products