Aleta.hr

Details

  • Low-voltage industrial components
  • Frequency converter =< 1 kV
  • 1 KOM
  • EATON

Technical specifications

Depth270mm
Power consumption1110W
Width235mm
Height540mm
With control elementYes
Number of digital inputs5
Supporting protocol for LONNo
Number of HW-interfaces industrial Ethernet0
Number of analogue inputs2
Number of HW-interfaces RS-4220
Number of HW-interfaces RS-2320
Number of digital outputs2
Number of analogue outputs2
Number of HW-interfaces RS-4851
Number of HW-interfaces serial TTY0
Number of HW-interfaces other0
With optical interfaceNo
Number of HW-interfaces parallel0
Supporting protocol for TCP/IPYes
Number of HW-interfaces USB0
Supporting protocol for ASINo
Supporting protocol for DeviceNetYes
Supporting protocol for SUCONETNo
Supporting protocol for INTERBUSNo
Supporting protocol for PROFIBUSYes
Supporting protocol for ModbusYes
Supporting protocol for KNXNo
Supporting protocol for CANYes
Supporting protocol for Data-HighwayNo
Supporting protocol for other bus systemsYes
Supporting protocol for SERCOSNo
Supporting protocol for INTERBUS-SafetyNo
With PC connectionYes
Mains voltage500 - 600V
Degree of protection (IP)IP55
Number of interfaces PROFINET0
Application in domestic- and commercial area permittedYes
Mains frequency50/60 Hz
Application in industrial area permittedYes
Integrated breaking resistanceYes
Number of phases output3
Max. output frequency500Hz
Type of converterU converter
Number of phases input3
4-quadrant operation possibleYes
Supporting protocol for EtherNet/IPYes
Max. output at linear load at rated output voltage37kW
Supporting protocol for AS-Interface Safety at WorkNo
Max. output at quadratic load at rated output voltage37kW
Supporting protocol for DeviceNet SafetyNo
Relative symmetric net voltage tolerance10%
Supporting protocol for PROFINET CBANo
Relative symmetric net frequency tolerance10%
Supporting protocol for Foundation FieldbusNo
Supporting protocol for PROFIsafeNo
Supporting protocol for PROFINET IOYes
Supporting protocol for SafetyBUS pNo
Supporting protocol for BACnetNo
Nominal output current I2N54A
Max. output voltage600V
Degree of protection (NEMA)12

Related products

*VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user

DA1-35054NB-B55C

Main Product Image

Why Register?

  • View wholesale prices with discounts
  • Real-time stock availability
  • Access invoices and dispatch notes
  • Order history and frequently ordered items
  • Exclusive B2B offers

and much more...

Details

  • Low-voltage industrial components
  • Frequency converter =< 1 kV
  • 1 KOM
  • EATON

Technical specifications

Depth

270mm

Power consumption

1110W

Width

235mm

Height

540mm

With control element

Number of digital inputs

5

Supporting protocol for LON

Number of HW-interfaces industrial Ethernet

0

Number of analogue inputs

2

Number of HW-interfaces RS-422

0

Number of HW-interfaces RS-232

0

Number of digital outputs

2

Number of analogue outputs

2

Number of HW-interfaces RS-485

1

Number of HW-interfaces serial TTY

0

Number of HW-interfaces other

0

With optical interface

Number of HW-interfaces parallel

0

Supporting protocol for TCP/IP

Number of HW-interfaces USB

0

Supporting protocol for ASI

Supporting protocol for DeviceNet

Supporting protocol for SUCONET

Supporting protocol for INTERBUS

Supporting protocol for PROFIBUS

Supporting protocol for Modbus

Supporting protocol for KNX

Supporting protocol for CAN

Supporting protocol for Data-Highway

Supporting protocol for other bus systems

Supporting protocol for SERCOS

Supporting protocol for INTERBUS-Safety

With PC connection

Mains voltage

500 .. 600V

Degree of protection (IP)

IP55

Number of interfaces PROFINET

0

Application in domestic- and commercial area permitted

Mains frequency

50/60 Hz

Application in industrial area permitted

Integrated breaking resistance

Number of phases output

3

Max. output frequency

500Hz

Type of converter

U converter

Number of phases input

3

4-quadrant operation possible

Supporting protocol for EtherNet/IP

Max. output at linear load at rated output voltage

37kW

Supporting protocol for AS-Interface Safety at Work

Max. output at quadratic load at rated output voltage

37kW

Supporting protocol for DeviceNet Safety

Relative symmetric net voltage tolerance

10%

Supporting protocol for PROFINET CBA

Relative symmetric net frequency tolerance

10%

Supporting protocol for Foundation Fieldbus

Supporting protocol for PROFIsafe

Supporting protocol for PROFINET IO

Supporting protocol for SafetyBUS p

Supporting protocol for BACnet

Nominal output current I2N

54A

Max. output voltage

600V

Degree of protection (NEMA)

12

Related products

VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user.