Aleta.hr

Details

  • Low-voltage industrial components
  • Frequency converter =< 1 kV
  • 1 KOM
  • EATON

Technical specifications

Supporting protocol for TCP/IPYes
Number of digital inputs5
Depth313.5mm
With control elementYes
With optical interfaceNo
Number of HW-interfaces industrial Ethernet0
Number of HW-interfaces RS-4220
Number of analogue inputs2
Width330mm
Number of HW-interfaces other0
Supporting protocol for LONNo
Number of HW-interfaces parallel0
Number of HW-interfaces RS-2320
Height865mm
Number of HW-interfaces serial TTY0
Number of HW-interfaces USB0
Number of HW-interfaces RS-4851
Number of digital outputs2
Power consumption2700W
Number of analogue outputs2
Max. output frequency500Hz
Number of phases output3
Supporting protocol for INTERBUS-SafetyNo
Supporting protocol for DeviceNetYes
Supporting protocol for KNXNo
With PC connectionYes
Supporting protocol for ModbusYes
Supporting protocol for INTERBUSNo
Supporting protocol for SUCONETNo
Mains voltage500 - 600V
Mains frequency50/60 Hz
Application in industrial area permittedYes
Number of interfaces PROFINET0
Number of phases input3
Supporting protocol for PROFIBUSYes
4-quadrant operation possibleYes
Application in domestic- and commercial area permittedYes
Supporting protocol for Data-HighwayNo
Supporting protocol for other bus systemsYes
Supporting protocol for ASINo
Degree of protection (IP)IP55
Supporting protocol for SERCOSNo
Supporting protocol for CANYes
Integrated breaking resistanceYes
Type of converterU converter
Nominal output current I2N130A
Supporting protocol for EtherNet/IPYes
Degree of protection (NEMA)12
Supporting protocol for DeviceNet SafetyNo
Relative symmetric net voltage tolerance10%
Max. output at quadratic load at rated output voltage105kW
Supporting protocol for PROFINET CBANo
Max. output at linear load at rated output voltage105kW
Supporting protocol for PROFINET IOYes
Supporting protocol for Foundation FieldbusNo
Relative symmetric net frequency tolerance10%
Supporting protocol for SafetyBUS pNo
Supporting protocol for PROFIsafeNo
Max. output voltage600V
Supporting protocol for AS-Interface Safety at WorkNo
Supporting protocol for BACnetNo

Related products

*VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user

DA1-35130NB-B55C

Main Product Image

Why Register?

  • View wholesale prices with discounts
  • Real-time stock availability
  • Access invoices and dispatch notes
  • Order history and frequently ordered items
  • Exclusive B2B offers

and much more...

Details

  • Low-voltage industrial components
  • Frequency converter =< 1 kV
  • 1 KOM
  • EATON

Technical specifications

Supporting protocol for TCP/IP

Number of digital inputs

5

Depth

313.5mm

With control element

With optical interface

Number of HW-interfaces industrial Ethernet

0

Number of HW-interfaces RS-422

0

Number of analogue inputs

2

Width

330mm

Number of HW-interfaces other

0

Supporting protocol for LON

Number of HW-interfaces parallel

0

Number of HW-interfaces RS-232

0

Height

865mm

Number of HW-interfaces serial TTY

0

Number of HW-interfaces USB

0

Number of HW-interfaces RS-485

1

Number of digital outputs

2

Power consumption

2700W

Number of analogue outputs

2

Max. output frequency

500Hz

Number of phases output

3

Supporting protocol for INTERBUS-Safety

Supporting protocol for DeviceNet

Supporting protocol for KNX

With PC connection

Supporting protocol for Modbus

Supporting protocol for INTERBUS

Supporting protocol for SUCONET

Mains voltage

500 .. 600V

Mains frequency

50/60 Hz

Application in industrial area permitted

Number of interfaces PROFINET

0

Number of phases input

3

Supporting protocol for PROFIBUS

4-quadrant operation possible

Application in domestic- and commercial area permitted

Supporting protocol for Data-Highway

Supporting protocol for other bus systems

Supporting protocol for ASI

Degree of protection (IP)

IP55

Supporting protocol for SERCOS

Supporting protocol for CAN

Integrated breaking resistance

Type of converter

U converter

Nominal output current I2N

130A

Supporting protocol for EtherNet/IP

Degree of protection (NEMA)

12

Supporting protocol for DeviceNet Safety

Relative symmetric net voltage tolerance

10%

Max. output at quadratic load at rated output voltage

105kW

Supporting protocol for PROFINET CBA

Max. output at linear load at rated output voltage

105kW

Supporting protocol for PROFINET IO

Supporting protocol for Foundation Fieldbus

Relative symmetric net frequency tolerance

10%

Supporting protocol for SafetyBUS p

Supporting protocol for PROFIsafe

Max. output voltage

600V

Supporting protocol for AS-Interface Safety at Work

Supporting protocol for BACnet

Related products

VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user.