Aleta.hr

Details

  • Low-voltage industrial components
  • Frequency converter =< 1 kV
  • 1 KOM
  • EATON

Technical specifications

Number of HW-interfaces RS-2320
Number of analogue inputs2
Width330mm
With control elementYes
Number of digital outputs2
Height865mm
Number of digital inputs5
Power consumption3300W
Number of HW-interfaces RS-4851
Number of HW-interfaces industrial Ethernet0
Depth313.5mm
Supporting protocol for LONNo
Number of analogue outputs2
Number of HW-interfaces RS-4220
Supporting protocol for INTERBUS-SafetyNo
Supporting protocol for ModbusYes
With optical interfaceNo
4-quadrant operation possibleYes
Supporting protocol for INTERBUSNo
Supporting protocol for SUCONETNo
Mains voltage500 - 600V
Supporting protocol for Data-HighwayNo
Supporting protocol for KNXNo
Number of HW-interfaces USB0
Number of interfaces PROFINET0
Supporting protocol for DeviceNetYes
Number of HW-interfaces serial TTY0
Mains frequency50/60 Hz
Degree of protection (IP)IP55
Type of converterU converter
Supporting protocol for other bus systemsYes
With PC connectionYes
Supporting protocol for CANYes
Number of HW-interfaces other0
Number of HW-interfaces parallel0
Supporting protocol for ASINo
Supporting protocol for SERCOSNo
Supporting protocol for PROFIBUSYes
Supporting protocol for TCP/IPYes
Application in industrial area permittedYes
Supporting protocol for SafetyBUS pNo
Max. output at quadratic load at rated output voltage130kW
Supporting protocol for BACnetNo
Supporting protocol for PROFIsafeNo
Supporting protocol for Foundation FieldbusNo
Supporting protocol for DeviceNet SafetyNo
Number of phases output3
Relative symmetric net frequency tolerance10%
Application in domestic- and commercial area permittedYes
Max. output voltage600V
Nominal output current I2N150A
Integrated breaking resistanceYes
Relative symmetric net voltage tolerance10%
Max. output frequency500Hz
Supporting protocol for PROFINET IOYes
Degree of protection (NEMA)12
Number of phases input3
Supporting protocol for AS-Interface Safety at WorkNo
Max. output at linear load at rated output voltage130kW
Supporting protocol for PROFINET CBANo
Supporting protocol for EtherNet/IPYes

Related products

*VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user

DA1-35150NB-B55C

Main Product Image

Why Register?

  • View wholesale prices with discounts
  • Real-time stock availability
  • Access invoices and dispatch notes
  • Order history and frequently ordered items
  • Exclusive B2B offers

and much more...

Details

  • Low-voltage industrial components
  • Frequency converter =< 1 kV
  • 1 KOM
  • EATON

Technical specifications

Number of HW-interfaces RS-232

0

Number of analogue inputs

2

Width

330mm

With control element

Number of digital outputs

2

Height

865mm

Number of digital inputs

5

Power consumption

3300W

Number of HW-interfaces RS-485

1

Number of HW-interfaces industrial Ethernet

0

Depth

313.5mm

Supporting protocol for LON

Number of analogue outputs

2

Number of HW-interfaces RS-422

0

Supporting protocol for INTERBUS-Safety

Supporting protocol for Modbus

With optical interface

4-quadrant operation possible

Supporting protocol for INTERBUS

Supporting protocol for SUCONET

Mains voltage

500 .. 600V

Supporting protocol for Data-Highway

Supporting protocol for KNX

Number of HW-interfaces USB

0

Number of interfaces PROFINET

0

Supporting protocol for DeviceNet

Number of HW-interfaces serial TTY

0

Mains frequency

50/60 Hz

Degree of protection (IP)

IP55

Type of converter

U converter

Supporting protocol for other bus systems

With PC connection

Supporting protocol for CAN

Number of HW-interfaces other

0

Number of HW-interfaces parallel

0

Supporting protocol for ASI

Supporting protocol for SERCOS

Supporting protocol for PROFIBUS

Supporting protocol for TCP/IP

Application in industrial area permitted

Supporting protocol for SafetyBUS p

Max. output at quadratic load at rated output voltage

130kW

Supporting protocol for BACnet

Supporting protocol for PROFIsafe

Supporting protocol for Foundation Fieldbus

Supporting protocol for DeviceNet Safety

Number of phases output

3

Relative symmetric net frequency tolerance

10%

Application in domestic- and commercial area permitted

Max. output voltage

600V

Nominal output current I2N

150A

Integrated breaking resistance

Relative symmetric net voltage tolerance

10%

Max. output frequency

500Hz

Supporting protocol for PROFINET IO

Degree of protection (NEMA)

12

Number of phases input

3

Supporting protocol for AS-Interface Safety at Work

Max. output at linear load at rated output voltage

130kW

Supporting protocol for PROFINET CBA

Supporting protocol for EtherNet/IP

Related products

VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user.