Technical specifications

Power consumption160W
Number of analogue inputs2
Width210.5mm
Depth238mm
With control elementYes
Height310mm
Number of digital outputs1
Number of digital inputs4
Number of HW-interfaces RS-2320
Number of analogue outputs1
Number of HW-interfaces industrial Ethernet0
Number of HW-interfaces RS-4220
Supporting protocol for LONNo
With optical interfaceNo
Number of HW-interfaces parallel0
Number of HW-interfaces RS-4851
Number of HW-interfaces serial TTY0
Supporting protocol for ASINo
Number of HW-interfaces USB0
Supporting protocol for TCP/IPNo
Mains frequency50/60 Hz
Number of HW-interfaces other0
Supporting protocol for SUCONETNo
Supporting protocol for Data-HighwayNo
4-quadrant operation possibleYes
Supporting protocol for DeviceNetNo
With PC connectionYes
Supporting protocol for other bus systemsYes
Degree of protection (IP)IP66
Supporting protocol for KNXNo
Supporting protocol for INTERBUSNo
Supporting protocol for ModbusYes
Supporting protocol for CANYes
Supporting protocol for PROFIBUSNo
Supporting protocol for SERCOSNo
Number of interfaces PROFINET0
Mains voltage200 - 240V
Supporting protocol for INTERBUS-SafetyNo
Number of phases output3
Supporting protocol for EtherNet/IPYes
Supporting protocol for PROFINET CBANo
Type of converterU converter
Number of phases input1
Max. output frequency500Hz
Max. output at quadratic load at rated output voltage2.2kW
Application in industrial area permittedYes
Relative symmetric net frequency tolerance10%
Application in domestic- and commercial area permittedYes
Supporting protocol for AS-Interface Safety at WorkNo
Supporting protocol for DeviceNet SafetyNo
Relative symmetric net voltage tolerance10%
Max. output at linear load at rated output voltage2.2kW
Supporting protocol for Foundation FieldbusNo
Integrated breaking resistanceYes
Supporting protocol for PROFIsafeNo
Degree of protection (NEMA)4X
Supporting protocol for PROFINET IONo
Supporting protocol for BACnetNo
Nominal output current I2N15.3A
Max. output voltage250V
Supporting protocol for SafetyBUS pNo

Related products

*VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user

DC1-12015FB-A6SOE1

Main Product Image

Why Register?

  • View wholesale prices with discounts
  • Real-time stock availability
  • Access invoices and dispatch notes
  • Order history and frequently ordered items
  • Exclusive B2B offers

and much more...

Details

  • Low-voltage industrial components
  • Frequency converter =< 1 kV
  • 1 KOM
  • EATON

Technical specifications

Power consumption

160W

Number of analogue inputs

2

Width

210.5mm

Depth

238mm

With control element

Height

310mm

Number of digital outputs

1

Number of digital inputs

4

Number of HW-interfaces RS-232

0

Number of analogue outputs

1

Number of HW-interfaces industrial Ethernet

0

Number of HW-interfaces RS-422

0

Supporting protocol for LON

With optical interface

Number of HW-interfaces parallel

0

Number of HW-interfaces RS-485

1

Number of HW-interfaces serial TTY

0

Supporting protocol for ASI

Number of HW-interfaces USB

0

Supporting protocol for TCP/IP

Mains frequency

50/60 Hz

Number of HW-interfaces other

0

Supporting protocol for SUCONET

Supporting protocol for Data-Highway

4-quadrant operation possible

Supporting protocol for DeviceNet

With PC connection

Supporting protocol for other bus systems

Degree of protection (IP)

IP66

Supporting protocol for KNX

Supporting protocol for INTERBUS

Supporting protocol for Modbus

Supporting protocol for CAN

Supporting protocol for PROFIBUS

Supporting protocol for SERCOS

Number of interfaces PROFINET

0

Mains voltage

200 .. 240V

Supporting protocol for INTERBUS-Safety

Number of phases output

3

Supporting protocol for EtherNet/IP

Supporting protocol for PROFINET CBA

Type of converter

U converter

Number of phases input

1

Max. output frequency

500Hz

Max. output at quadratic load at rated output voltage

2.2kW

Application in industrial area permitted

Relative symmetric net frequency tolerance

10%

Application in domestic- and commercial area permitted

Supporting protocol for AS-Interface Safety at Work

Supporting protocol for DeviceNet Safety

Relative symmetric net voltage tolerance

10%

Max. output at linear load at rated output voltage

2.2kW

Supporting protocol for Foundation Fieldbus

Integrated breaking resistance

Supporting protocol for PROFIsafe

Degree of protection (NEMA)

4X

Supporting protocol for PROFINET IO

Supporting protocol for BACnet

Nominal output current I2N

15.3A

Max. output voltage

250V

Supporting protocol for SafetyBUS p

Related products