Technical specifications

Width161mm
Depth162mm
Height232mm
Power consumption18.5W
Supporting protocol for SUCONETNo
Number of HW-interfaces RS-2320
Number of HW-interfaces USB0
With control elementYes
Number of HW-interfaces RS-4851
Number of HW-interfaces RS-4220
With optical interfaceNo
Supporting protocol for DeviceNetNo
Number of HW-interfaces serial TTY0
Number of analogue inputs2
Supporting protocol for ASINo
Supporting protocol for TCP/IPNo
Supporting protocol for PROFIBUSNo
Supporting protocol for LONNo
Number of analogue outputs1
Supporting protocol for CANYes
Supporting protocol for Data-HighwayNo
Supporting protocol for INTERBUSNo
Supporting protocol for ModbusYes
Number of digital outputs1
Number of HW-interfaces parallel0
Supporting protocol for KNXNo
Number of HW-interfaces industrial Ethernet0
Number of digital inputs4
Number of HW-interfaces other0
Degree of protection (IP)IP66
Supporting protocol for PROFINET CBANo
Max. output frequency500Hz
Relative symmetric net voltage tolerance10%
Supporting protocol for SERCOSNo
Number of phases input1
Max. output at quadratic load at rated output voltage0.37kW
Integrated breaking resistanceNo
Max. output at linear load at rated output voltage0.37kW
Application in domestic- and commercial area permittedYes
With PC connectionYes
Mains voltage110 - 115V
Application in industrial area permittedYes
Supporting protocol for INTERBUS-SafetyNo
Number of phases output3
4-quadrant operation possibleNo
Supporting protocol for AS-Interface Safety at WorkNo
Supporting protocol for DeviceNet SafetyNo
Type of converterU converter
Supporting protocol for Foundation FieldbusNo
Supporting protocol for EtherNet/IPYes
Relative symmetric net frequency tolerance10%
Number of interfaces PROFINET0
Mains frequency50/60 Hz
Supporting protocol for other bus systemsYes
Supporting protocol for PROFINET IONo
Supporting protocol for SafetyBUS pNo
Degree of protection (NEMA)4X
Supporting protocol for BACnetNo
Max. output voltage250V
Supporting protocol for PROFIsafeNo
Nominal output current I2N2.3A

Related products

*VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user

DC1-1D2D3NN-A6SOE1

Main Product Image

Why Register?

  • View wholesale prices with discounts
  • Real-time stock availability
  • Access invoices and dispatch notes
  • Order history and frequently ordered items
  • Exclusive B2B offers

and much more...

Details

  • Low-voltage industrial components
  • Frequency converter =< 1 kV
  • 1 KOM
  • EATON

Technical specifications

Width

161mm

Depth

162mm

Height

232mm

Power consumption

18.5W

Supporting protocol for SUCONET

Number of HW-interfaces RS-232

0

Number of HW-interfaces USB

0

With control element

Number of HW-interfaces RS-485

1

Number of HW-interfaces RS-422

0

With optical interface

Supporting protocol for DeviceNet

Number of HW-interfaces serial TTY

0

Number of analogue inputs

2

Supporting protocol for ASI

Supporting protocol for TCP/IP

Supporting protocol for PROFIBUS

Supporting protocol for LON

Number of analogue outputs

1

Supporting protocol for CAN

Supporting protocol for Data-Highway

Supporting protocol for INTERBUS

Supporting protocol for Modbus

Number of digital outputs

1

Number of HW-interfaces parallel

0

Supporting protocol for KNX

Number of HW-interfaces industrial Ethernet

0

Number of digital inputs

4

Number of HW-interfaces other

0

Degree of protection (IP)

IP66

Supporting protocol for PROFINET CBA

Max. output frequency

500Hz

Relative symmetric net voltage tolerance

10%

Supporting protocol for SERCOS

Number of phases input

1

Max. output at quadratic load at rated output voltage

0.37kW

Integrated breaking resistance

Max. output at linear load at rated output voltage

0.37kW

Application in domestic- and commercial area permitted

With PC connection

Mains voltage

110 .. 115V

Application in industrial area permitted

Supporting protocol for INTERBUS-Safety

Number of phases output

3

4-quadrant operation possible

Supporting protocol for AS-Interface Safety at Work

Supporting protocol for DeviceNet Safety

Type of converter

U converter

Supporting protocol for Foundation Fieldbus

Supporting protocol for EtherNet/IP

Relative symmetric net frequency tolerance

10%

Number of interfaces PROFINET

0

Mains frequency

50/60 Hz

Supporting protocol for other bus systems

Supporting protocol for PROFINET IO

Supporting protocol for SafetyBUS p

Degree of protection (NEMA)

4X

Supporting protocol for BACnet

Max. output voltage

250V

Supporting protocol for PROFIsafe

Nominal output current I2N

2.3A