Aleta.hr

Details

  • Low-voltage industrial components
  • Frequency converter =< 1 kV
  • 1 KOM
  • EATON

Technical specifications

Number of analogue outputs1
Depth182mm
Number of HW-interfaces RS-4851
Number of digital outputs1
Number of analogue inputs2
Number of HW-interfaces RS-4220
Number of HW-interfaces industrial Ethernet0
Power consumption44W
Number of HW-interfaces RS-2320
Width188mm
Height257mm
Number of HW-interfaces serial TTY0
Number of digital inputs4
With control elementYes
Supporting protocol for LONNo
Number of HW-interfaces parallel0
Number of HW-interfaces other0
With optical interfaceNo
Number of HW-interfaces USB0
Supporting protocol for KNXNo
Supporting protocol for other bus systemsYes
Integrated breaking resistanceYes
Supporting protocol for SUCONETNo
Degree of protection (IP)IP66
Supporting protocol for PROFIBUSNo
With PC connectionYes
Number of interfaces PROFINET0
Supporting protocol for SERCOSNo
Type of converterU converter
4-quadrant operation possibleYes
Supporting protocol for INTERBUSNo
Supporting protocol for DeviceNetNo
Mains frequency50/60 Hz
Mains voltage110 - 115V
Supporting protocol for INTERBUS-SafetyNo
Number of phases input1
Supporting protocol for CANYes
Supporting protocol for Data-HighwayNo
Supporting protocol for ASINo
Number of phases output3
Supporting protocol for ModbusYes
Application in domestic- and commercial area permittedYes
Supporting protocol for TCP/IPNo
Application in industrial area permittedYes
Max. output at linear load at rated output voltage1.1kW
Max. output voltage250V
Supporting protocol for PROFINET IONo
Nominal output current I2N5.8A
Supporting protocol for PROFINET CBANo
Max. output frequency500Hz
Supporting protocol for Foundation FieldbusNo
Supporting protocol for DeviceNet SafetyNo
Supporting protocol for SafetyBUS pNo
Max. output at quadratic load at rated output voltage1.1kW
Supporting protocol for BACnetNo
Degree of protection (NEMA)4X
Supporting protocol for EtherNet/IPYes
Supporting protocol for PROFIsafeNo
Relative symmetric net frequency tolerance10%
Relative symmetric net voltage tolerance10%
Supporting protocol for AS-Interface Safety at WorkNo

Related products

*VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user

DC1-1D5D8NB-A6SOE1

Main Product Image

Why Register?

  • View wholesale prices with discounts
  • Real-time stock availability
  • Access invoices and dispatch notes
  • Order history and frequently ordered items
  • Exclusive B2B offers

and much more...

Details

  • Low-voltage industrial components
  • Frequency converter =< 1 kV
  • 1 KOM
  • EATON

Technical specifications

Number of analogue outputs

1

Depth

182mm

Number of HW-interfaces RS-485

1

Number of digital outputs

1

Number of analogue inputs

2

Number of HW-interfaces RS-422

0

Number of HW-interfaces industrial Ethernet

0

Power consumption

44W

Number of HW-interfaces RS-232

0

Width

188mm

Height

257mm

Number of HW-interfaces serial TTY

0

Number of digital inputs

4

With control element

Supporting protocol for LON

Number of HW-interfaces parallel

0

Number of HW-interfaces other

0

With optical interface

Number of HW-interfaces USB

0

Supporting protocol for KNX

Supporting protocol for other bus systems

Integrated breaking resistance

Supporting protocol for SUCONET

Degree of protection (IP)

IP66

Supporting protocol for PROFIBUS

With PC connection

Number of interfaces PROFINET

0

Supporting protocol for SERCOS

Type of converter

U converter

4-quadrant operation possible

Supporting protocol for INTERBUS

Supporting protocol for DeviceNet

Mains frequency

50/60 Hz

Mains voltage

110 .. 115V

Supporting protocol for INTERBUS-Safety

Number of phases input

1

Supporting protocol for CAN

Supporting protocol for Data-Highway

Supporting protocol for ASI

Number of phases output

3

Supporting protocol for Modbus

Application in domestic- and commercial area permitted

Supporting protocol for TCP/IP

Application in industrial area permitted

Max. output at linear load at rated output voltage

1.1kW

Max. output voltage

250V

Supporting protocol for PROFINET IO

Nominal output current I2N

5.8A

Supporting protocol for PROFINET CBA

Max. output frequency

500Hz

Supporting protocol for Foundation Fieldbus

Supporting protocol for DeviceNet Safety

Supporting protocol for SafetyBUS p

Max. output at quadratic load at rated output voltage

1.1kW

Supporting protocol for BACnet

Degree of protection (NEMA)

4X

Supporting protocol for EtherNet/IP

Supporting protocol for PROFIsafe

Relative symmetric net frequency tolerance

10%

Relative symmetric net voltage tolerance

10%

Supporting protocol for AS-Interface Safety at Work

Related products