Aleta.hr

Details

  • Low-voltage industrial components
  • Frequency converter =< 1 kV
  • 1 KOM
  • EATON

Technical specifications

Depth182mm
Width188mm
Height257mm
With control elementYes
Power consumption90.2W
Supporting protocol for ModbusYes
Number of HW-interfaces RS-4220
Number of analogue inputs2
Number of digital outputs1
Supporting protocol for Data-HighwayNo
Number of digital inputs4
Supporting protocol for ASINo
Supporting protocol for KNXNo
Number of HW-interfaces RS-2320
Number of HW-interfaces industrial Ethernet0
Supporting protocol for TCP/IPNo
Supporting protocol for PROFIBUSNo
Supporting protocol for LONNo
Number of HW-interfaces parallel0
Number of analogue outputs1
Number of HW-interfaces serial TTY0
Supporting protocol for CANYes
Number of HW-interfaces RS-4851
Number of HW-interfaces USB0
Number of HW-interfaces other0
Supporting protocol for INTERBUSNo
With optical interfaceNo
Supporting protocol for other bus systemsYes
Supporting protocol for DeviceNetNo
Supporting protocol for SUCONETNo
Supporting protocol for INTERBUS-SafetyNo
Degree of protection (IP)IP66
With PC connectionYes
Integrated breaking resistanceYes
Supporting protocol for SERCOSNo
4-quadrant operation possibleYes
Number of phases input3
Mains frequency50/60 Hz
Number of phases output3
Application in industrial area permittedYes
Mains voltage200 - 240V
Max. output frequency500Hz
Max. output at linear load at rated output voltage2.2kW
Number of interfaces PROFINET0
Application in domestic- and commercial area permittedYes
Type of converterU converter
Max. output at quadratic load at rated output voltage2.2kW
Supporting protocol for Foundation FieldbusNo
Supporting protocol for EtherNet/IPYes
Supporting protocol for PROFINET IONo
Supporting protocol for PROFINET CBANo
Supporting protocol for DeviceNet SafetyNo
Relative symmetric net frequency tolerance10%
Relative symmetric net voltage tolerance10%
Supporting protocol for AS-Interface Safety at WorkNo
Degree of protection (NEMA)4X
Supporting protocol for BACnetNo
Max. output voltage250V
Supporting protocol for SafetyBUS pNo
Nominal output current I2N10.5A
Supporting protocol for PROFIsafeNo

Related products

*VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user

DC1-32011FB-A66OE1

Main Product Image

Why Register?

  • View wholesale prices with discounts
  • Real-time stock availability
  • Access invoices and dispatch notes
  • Order history and frequently ordered items
  • Exclusive B2B offers

and much more...

Details

  • Low-voltage industrial components
  • Frequency converter =< 1 kV
  • 1 KOM
  • EATON

Technical specifications

Depth

182mm

Width

188mm

Height

257mm

With control element

Power consumption

90.2W

Supporting protocol for Modbus

Number of HW-interfaces RS-422

0

Number of analogue inputs

2

Number of digital outputs

1

Supporting protocol for Data-Highway

Number of digital inputs

4

Supporting protocol for ASI

Supporting protocol for KNX

Number of HW-interfaces RS-232

0

Number of HW-interfaces industrial Ethernet

0

Supporting protocol for TCP/IP

Supporting protocol for PROFIBUS

Supporting protocol for LON

Number of HW-interfaces parallel

0

Number of analogue outputs

1

Number of HW-interfaces serial TTY

0

Supporting protocol for CAN

Number of HW-interfaces RS-485

1

Number of HW-interfaces USB

0

Number of HW-interfaces other

0

Supporting protocol for INTERBUS

With optical interface

Supporting protocol for other bus systems

Supporting protocol for DeviceNet

Supporting protocol for SUCONET

Supporting protocol for INTERBUS-Safety

Degree of protection (IP)

IP66

With PC connection

Integrated breaking resistance

Supporting protocol for SERCOS

4-quadrant operation possible

Number of phases input

3

Mains frequency

50/60 Hz

Number of phases output

3

Application in industrial area permitted

Mains voltage

200 .. 240V

Max. output frequency

500Hz

Max. output at linear load at rated output voltage

2.2kW

Number of interfaces PROFINET

0

Application in domestic- and commercial area permitted

Type of converter

U converter

Max. output at quadratic load at rated output voltage

2.2kW

Supporting protocol for Foundation Fieldbus

Supporting protocol for EtherNet/IP

Supporting protocol for PROFINET IO

Supporting protocol for PROFINET CBA

Supporting protocol for DeviceNet Safety

Relative symmetric net frequency tolerance

10%

Relative symmetric net voltage tolerance

10%

Supporting protocol for AS-Interface Safety at Work

Degree of protection (NEMA)

4X

Supporting protocol for BACnet

Max. output voltage

250V

Supporting protocol for SafetyBUS p

Nominal output current I2N

10.5A

Supporting protocol for PROFIsafe

Related products

VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user.