Aleta.hr

Details

  • Low-voltage industrial components
  • Frequency converter =< 1 kV
  • 1 KOM
  • EATON

Technical specifications

Height232mm
Width161mm
With control elementYes
Power consumption61.5W
Depth162mm
Number of digital inputs4
Supporting protocol for LONNo
Number of HW-interfaces RS-2320
Number of HW-interfaces industrial Ethernet0
With optical interfaceNo
Number of HW-interfaces other0
Number of HW-interfaces RS-4220
Number of HW-interfaces USB0
Supporting protocol for TCP/IPNo
Number of analogue outputs1
Number of analogue inputs2
Number of HW-interfaces RS-4851
Number of HW-interfaces parallel0
Supporting protocol for PROFIBUSNo
Supporting protocol for ASINo
Supporting protocol for CANYes
Number of digital outputs1
Supporting protocol for DeviceNetNo
Supporting protocol for SUCONETNo
Supporting protocol for ModbusYes
Supporting protocol for KNXNo
Supporting protocol for other bus systemsYes
Supporting protocol for Data-HighwayNo
Number of HW-interfaces serial TTY0
Supporting protocol for INTERBUSNo
Degree of protection (IP)IP66
With PC connectionYes
Supporting protocol for SERCOSNo
Supporting protocol for INTERBUS-SafetyNo
Number of interfaces PROFINET0
Type of converterU converter
Mains frequency50/60 Hz
Mains voltage200 - 240V
Number of phases output3
4-quadrant operation possibleNo
Max. output at quadratic load at rated output voltage1.5kW
Relative symmetric net voltage tolerance10%
Max. output frequency500Hz
Application in domestic- and commercial area permittedYes
Integrated breaking resistanceNo
Max. output at linear load at rated output voltage1.5kW
Application in industrial area permittedYes
Relative symmetric net frequency tolerance10%
Supporting protocol for DeviceNet SafetyNo
Supporting protocol for AS-Interface Safety at WorkNo
Supporting protocol for PROFIsafeNo
Supporting protocol for Foundation FieldbusNo
Supporting protocol for PROFINET CBANo
Number of phases input3
Supporting protocol for PROFINET IONo
Supporting protocol for EtherNet/IPYes
Supporting protocol for BACnetNo
Max. output voltage250V
Nominal output current I2N7A
Degree of protection (NEMA)4X
Supporting protocol for SafetyBUS pNo

Related products

*VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user

DC1-327D0FN-A66OE1

Main Product Image

Why Register?

  • View wholesale prices with discounts
  • Real-time stock availability
  • Access invoices and dispatch notes
  • Order history and frequently ordered items
  • Exclusive B2B offers

and much more...

Details

  • Low-voltage industrial components
  • Frequency converter =< 1 kV
  • 1 KOM
  • EATON

Technical specifications

Height

232mm

Width

161mm

With control element

Power consumption

61.5W

Depth

162mm

Number of digital inputs

4

Supporting protocol for LON

Number of HW-interfaces RS-232

0

Number of HW-interfaces industrial Ethernet

0

With optical interface

Number of HW-interfaces other

0

Number of HW-interfaces RS-422

0

Number of HW-interfaces USB

0

Supporting protocol for TCP/IP

Number of analogue outputs

1

Number of analogue inputs

2

Number of HW-interfaces RS-485

1

Number of HW-interfaces parallel

0

Supporting protocol for PROFIBUS

Supporting protocol for ASI

Supporting protocol for CAN

Number of digital outputs

1

Supporting protocol for DeviceNet

Supporting protocol for SUCONET

Supporting protocol for Modbus

Supporting protocol for KNX

Supporting protocol for other bus systems

Supporting protocol for Data-Highway

Number of HW-interfaces serial TTY

0

Supporting protocol for INTERBUS

Degree of protection (IP)

IP66

With PC connection

Supporting protocol for SERCOS

Supporting protocol for INTERBUS-Safety

Number of interfaces PROFINET

0

Type of converter

U converter

Mains frequency

50/60 Hz

Mains voltage

200 .. 240V

Number of phases output

3

4-quadrant operation possible

Max. output at quadratic load at rated output voltage

1.5kW

Relative symmetric net voltage tolerance

10%

Max. output frequency

500Hz

Application in domestic- and commercial area permitted

Integrated breaking resistance

Max. output at linear load at rated output voltage

1.5kW

Application in industrial area permitted

Relative symmetric net frequency tolerance

10%

Supporting protocol for DeviceNet Safety

Supporting protocol for AS-Interface Safety at Work

Supporting protocol for PROFIsafe

Supporting protocol for Foundation Fieldbus

Supporting protocol for PROFINET CBA

Number of phases input

3

Supporting protocol for PROFINET IO

Supporting protocol for EtherNet/IP

Supporting protocol for BACnet

Max. output voltage

250V

Nominal output current I2N

7A

Degree of protection (NEMA)

4X

Supporting protocol for SafetyBUS p

Related products