Aleta.hr

Details

  • Low-voltage industrial components
  • Frequency converter =< 1 kV
  • 1 KOM
  • EATON

Technical specifications

Number of analogue inputs2
Power consumption304W
Number of HW-interfaces serial TTY0
Number of HW-interfaces RS-4851
Number of HW-interfaces industrial Ethernet0
Number of HW-interfaces RS-4220
Depth238mm
Number of HW-interfaces USB0
Number of analogue outputs1
Number of digital inputs4
Height310mm
Number of HW-interfaces RS-2320
Supporting protocol for LONNo
With control elementYes
Number of digital outputs1
Width210.5mm
Supporting protocol for TCP/IPNo
Supporting protocol for ASINo
With optical interfaceNo
Number of HW-interfaces other0
Number of HW-interfaces parallel0
Supporting protocol for INTERBUSNo
Supporting protocol for KNXNo
Supporting protocol for CANYes
Supporting protocol for SERCOSNo
4-quadrant operation possibleYes
Supporting protocol for DeviceNetNo
Supporting protocol for ModbusYes
Degree of protection (IP)IP66
Supporting protocol for INTERBUS-SafetyNo
Supporting protocol for Data-HighwayNo
Number of interfaces PROFINET0
Supporting protocol for PROFIBUSNo
Supporting protocol for SUCONETNo
Type of converterU converter
Supporting protocol for other bus systemsYes
Mains frequency50/60 Hz
Mains voltage380 - 480V
With PC connectionYes
Max. output at linear load at rated output voltage7.5kW
Integrated breaking resistanceYes
Number of phases output3
Number of phases input3
Application in industrial area permittedYes
Max. output frequency500Hz
Application in domestic- and commercial area permittedYes
Supporting protocol for Foundation FieldbusNo
Supporting protocol for DeviceNet SafetyNo
Max. output at quadratic load at rated output voltage7.5kW
Supporting protocol for AS-Interface Safety at WorkNo
Relative symmetric net voltage tolerance10%
Relative symmetric net frequency tolerance10%
Supporting protocol for BACnetNo
Degree of protection (NEMA)4X
Supporting protocol for SafetyBUS pNo
Supporting protocol for EtherNet/IPYes
Supporting protocol for PROFINET CBANo
Nominal output current I2N18A
Supporting protocol for PROFIsafeNo
Max. output voltage500V
Supporting protocol for PROFINET IONo

Related products

*VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user

DC1-34018FB-A66OE1

Main Product Image

Why Register?

  • View wholesale prices with discounts
  • Real-time stock availability
  • Access invoices and dispatch notes
  • Order history and frequently ordered items
  • Exclusive B2B offers

and much more...

Details

  • Low-voltage industrial components
  • Frequency converter =< 1 kV
  • 1 KOM
  • EATON

Technical specifications

Number of analogue inputs

2

Power consumption

304W

Number of HW-interfaces serial TTY

0

Number of HW-interfaces RS-485

1

Number of HW-interfaces industrial Ethernet

0

Number of HW-interfaces RS-422

0

Depth

238mm

Number of HW-interfaces USB

0

Number of analogue outputs

1

Number of digital inputs

4

Height

310mm

Number of HW-interfaces RS-232

0

Supporting protocol for LON

With control element

Number of digital outputs

1

Width

210.5mm

Supporting protocol for TCP/IP

Supporting protocol for ASI

With optical interface

Number of HW-interfaces other

0

Number of HW-interfaces parallel

0

Supporting protocol for INTERBUS

Supporting protocol for KNX

Supporting protocol for CAN

Supporting protocol for SERCOS

4-quadrant operation possible

Supporting protocol for DeviceNet

Supporting protocol for Modbus

Degree of protection (IP)

IP66

Supporting protocol for INTERBUS-Safety

Supporting protocol for Data-Highway

Number of interfaces PROFINET

0

Supporting protocol for PROFIBUS

Supporting protocol for SUCONET

Type of converter

U converter

Supporting protocol for other bus systems

Mains frequency

50/60 Hz

Mains voltage

380 .. 480V

With PC connection

Max. output at linear load at rated output voltage

7.5kW

Integrated breaking resistance

Number of phases output

3

Number of phases input

3

Application in industrial area permitted

Max. output frequency

500Hz

Application in domestic- and commercial area permitted

Supporting protocol for Foundation Fieldbus

Supporting protocol for DeviceNet Safety

Max. output at quadratic load at rated output voltage

7.5kW

Supporting protocol for AS-Interface Safety at Work

Relative symmetric net voltage tolerance

10%

Relative symmetric net frequency tolerance

10%

Supporting protocol for BACnet

Degree of protection (NEMA)

4X

Supporting protocol for SafetyBUS p

Supporting protocol for EtherNet/IP

Supporting protocol for PROFINET CBA

Nominal output current I2N

18A

Supporting protocol for PROFIsafe

Max. output voltage

500V

Supporting protocol for PROFINET IO

Related products

VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user.