Aleta.hr

Details

  • Low-voltage industrial components
  • Frequency converter =< 1 kV
  • 1 KOM
  • EATON

Technical specifications

Width210.5mm
Number of digital inputs4
Number of HW-interfaces RS-4851
Number of HW-interfaces RS-2320
Depth238mm
Height310mm
Number of HW-interfaces industrial Ethernet0
Supporting protocol for TCP/IPNo
Supporting protocol for ASINo
With control elementYes
Supporting protocol for KNXNo
Number of HW-interfaces RS-4220
Number of HW-interfaces parallel0
Supporting protocol for LONNo
Number of HW-interfaces other0
Number of digital outputs1
With optical interfaceNo
Number of analogue inputs2
Number of analogue outputs1
Number of HW-interfaces USB0
Number of HW-interfaces serial TTY0
Power consumption446W
Supporting protocol for PROFIBUSNo
Supporting protocol for ModbusYes
Supporting protocol for INTERBUSNo
Supporting protocol for CANYes
Supporting protocol for DeviceNetNo
Supporting protocol for Data-HighwayNo
Number of phases input3
Number of interfaces PROFINET0
Mains voltage380 - 480V
Integrated breaking resistanceYes
Supporting protocol for INTERBUS-SafetyNo
Max. output at quadratic load at rated output voltage11kW
Application in domestic- and commercial area permittedYes
Degree of protection (IP)IP66
With PC connectionYes
Relative symmetric net frequency tolerance10%
Type of converterU converter
4-quadrant operation possibleYes
Relative symmetric net voltage tolerance10%
Supporting protocol for SUCONETNo
Application in industrial area permittedYes
Max. output frequency500Hz
Supporting protocol for other bus systemsYes
Mains frequency50/60 Hz
Number of phases output3
Supporting protocol for DeviceNet SafetyNo
Supporting protocol for SERCOSNo
Supporting protocol for AS-Interface Safety at WorkNo
Max. output at linear load at rated output voltage11kW
Supporting protocol for SafetyBUS pNo
Supporting protocol for BACnetNo
Supporting protocol for Foundation FieldbusNo
Supporting protocol for PROFIsafeNo
Degree of protection (NEMA)4X
Supporting protocol for EtherNet/IPYes
Supporting protocol for PROFINET IONo
Max. output voltage500V
Nominal output current I2N24A
Supporting protocol for PROFINET CBANo

Related products

*VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user

DC1-34024FB-A6SOE1

Main Product Image

Why Register?

  • View wholesale prices with discounts
  • Real-time stock availability
  • Access invoices and dispatch notes
  • Order history and frequently ordered items
  • Exclusive B2B offers

and much more...

Details

  • Low-voltage industrial components
  • Frequency converter =< 1 kV
  • 1 KOM
  • EATON

Technical specifications

Width

210.5mm

Number of digital inputs

4

Number of HW-interfaces RS-485

1

Number of HW-interfaces RS-232

0

Depth

238mm

Height

310mm

Number of HW-interfaces industrial Ethernet

0

Supporting protocol for TCP/IP

Supporting protocol for ASI

With control element

Supporting protocol for KNX

Number of HW-interfaces RS-422

0

Number of HW-interfaces parallel

0

Supporting protocol for LON

Number of HW-interfaces other

0

Number of digital outputs

1

With optical interface

Number of analogue inputs

2

Number of analogue outputs

1

Number of HW-interfaces USB

0

Number of HW-interfaces serial TTY

0

Power consumption

446W

Supporting protocol for PROFIBUS

Supporting protocol for Modbus

Supporting protocol for INTERBUS

Supporting protocol for CAN

Supporting protocol for DeviceNet

Supporting protocol for Data-Highway

Number of phases input

3

Number of interfaces PROFINET

0

Mains voltage

380 .. 480V

Integrated breaking resistance

Supporting protocol for INTERBUS-Safety

Max. output at quadratic load at rated output voltage

11kW

Application in domestic- and commercial area permitted

Degree of protection (IP)

IP66

With PC connection

Relative symmetric net frequency tolerance

10%

Type of converter

U converter

4-quadrant operation possible

Relative symmetric net voltage tolerance

10%

Supporting protocol for SUCONET

Application in industrial area permitted

Max. output frequency

500Hz

Supporting protocol for other bus systems

Mains frequency

50/60 Hz

Number of phases output

3

Supporting protocol for DeviceNet Safety

Supporting protocol for SERCOS

Supporting protocol for AS-Interface Safety at Work

Max. output at linear load at rated output voltage

11kW

Supporting protocol for SafetyBUS p

Supporting protocol for BACnet

Supporting protocol for Foundation Fieldbus

Supporting protocol for PROFIsafe

Degree of protection (NEMA)

4X

Supporting protocol for EtherNet/IP

Supporting protocol for PROFINET IO

Max. output voltage

500V

Nominal output current I2N

24A

Supporting protocol for PROFINET CBA

Related products