Aleta.hr

Details

  • Low-voltage industrial components
  • Frequency converter =< 1 kV
  • 1 KOM
  • EATON

Technical specifications

Height232mm
Number of digital outputs1
With control elementYes
Width161mm
Number of HW-interfaces serial TTY0
Number of digital inputs4
With optical interfaceNo
Number of analogue inputs2
Number of HW-interfaces RS-4220
Number of HW-interfaces industrial Ethernet0
Number of HW-interfaces USB0
Supporting protocol for LONNo
Number of analogue outputs1
Depth162mm
Number of HW-interfaces parallel0
Number of HW-interfaces RS-2320
Power consumption33.75W
Number of HW-interfaces other0
Supporting protocol for CANYes
Supporting protocol for TCP/IPNo
Supporting protocol for ASINo
Supporting protocol for PROFIBUSNo
Number of HW-interfaces RS-4851
Supporting protocol for DeviceNetNo
Supporting protocol for INTERBUS-SafetyNo
Supporting protocol for KNXNo
Supporting protocol for ModbusYes
Supporting protocol for INTERBUSNo
Degree of protection (IP)IP66
4-quadrant operation possibleNo
Supporting protocol for SUCONETNo
Supporting protocol for Data-HighwayNo
Mains voltage380 - 480V
With PC connectionYes
Application in domestic- and commercial area permittedYes
Application in industrial area permittedYes
Number of interfaces PROFINET0
Type of converterU converter
Supporting protocol for SERCOSNo
Number of phases input3
Number of phases output3
Integrated breaking resistanceNo
Mains frequency50/60 Hz
Supporting protocol for other bus systemsYes
Relative symmetric net voltage tolerance10%
Max. output at quadratic load at rated output voltage0.75kW
Max. output frequency500Hz
Max. output at linear load at rated output voltage0.75kW
Supporting protocol for AS-Interface Safety at WorkNo
Relative symmetric net frequency tolerance10%
Supporting protocol for Foundation FieldbusNo
Supporting protocol for PROFINET CBANo
Supporting protocol for DeviceNet SafetyNo
Supporting protocol for EtherNet/IPYes
Supporting protocol for BACnetNo
Max. output voltage500V
Supporting protocol for PROFIsafeNo
Supporting protocol for SafetyBUS pNo
Nominal output current I2N2.2A
Supporting protocol for PROFINET IONo
Degree of protection (NEMA)4X

Related products

*VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user

DC1-342D2FN-A66OE1

Main Product Image

Why Register?

  • View wholesale prices with discounts
  • Real-time stock availability
  • Access invoices and dispatch notes
  • Order history and frequently ordered items
  • Exclusive B2B offers

and much more...

Details

  • Low-voltage industrial components
  • Frequency converter =< 1 kV
  • 1 KOM
  • EATON

Technical specifications

Height

232mm

Number of digital outputs

1

With control element

Width

161mm

Number of HW-interfaces serial TTY

0

Number of digital inputs

4

With optical interface

Number of analogue inputs

2

Number of HW-interfaces RS-422

0

Number of HW-interfaces industrial Ethernet

0

Number of HW-interfaces USB

0

Supporting protocol for LON

Number of analogue outputs

1

Depth

162mm

Number of HW-interfaces parallel

0

Number of HW-interfaces RS-232

0

Power consumption

33.75W

Number of HW-interfaces other

0

Supporting protocol for CAN

Supporting protocol for TCP/IP

Supporting protocol for ASI

Supporting protocol for PROFIBUS

Number of HW-interfaces RS-485

1

Supporting protocol for DeviceNet

Supporting protocol for INTERBUS-Safety

Supporting protocol for KNX

Supporting protocol for Modbus

Supporting protocol for INTERBUS

Degree of protection (IP)

IP66

4-quadrant operation possible

Supporting protocol for SUCONET

Supporting protocol for Data-Highway

Mains voltage

380 .. 480V

With PC connection

Application in domestic- and commercial area permitted

Application in industrial area permitted

Number of interfaces PROFINET

0

Type of converter

U converter

Supporting protocol for SERCOS

Number of phases input

3

Number of phases output

3

Integrated breaking resistance

Mains frequency

50/60 Hz

Supporting protocol for other bus systems

Relative symmetric net voltage tolerance

10%

Max. output at quadratic load at rated output voltage

0.75kW

Max. output frequency

500Hz

Max. output at linear load at rated output voltage

0.75kW

Supporting protocol for AS-Interface Safety at Work

Relative symmetric net frequency tolerance

10%

Supporting protocol for Foundation Fieldbus

Supporting protocol for PROFINET CBA

Supporting protocol for DeviceNet Safety

Supporting protocol for EtherNet/IP

Supporting protocol for BACnet

Max. output voltage

500V

Supporting protocol for PROFIsafe

Supporting protocol for SafetyBUS p

Nominal output current I2N

2.2A

Supporting protocol for PROFINET IO

Degree of protection (NEMA)

4X

Related products

VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user.