Aleta.hr

Details

  • Low-voltage industrial components
  • Frequency converter =< 1 kV
  • 1 KOM
  • EATON

Technical specifications

Height232mm
Width161mm
Depth162mm
Power consumption66.5W
Number of HW-interfaces industrial Ethernet0
Number of digital inputs4
Number of analogue inputs2
Number of digital outputs1
Number of HW-interfaces RS-2320
Number of analogue outputs1
Supporting protocol for LONNo
With control elementYes
Supporting protocol for ASINo
With optical interfaceNo
Number of HW-interfaces other0
Number of HW-interfaces RS-4220
Supporting protocol for TCP/IPNo
Number of HW-interfaces serial TTY0
Number of HW-interfaces USB0
Supporting protocol for other bus systemsYes
Supporting protocol for SUCONETNo
Supporting protocol for SERCOSNo
With PC connectionYes
Number of HW-interfaces parallel0
Supporting protocol for ModbusYes
Supporting protocol for DeviceNetNo
Supporting protocol for KNXNo
Number of HW-interfaces RS-4851
Supporting protocol for Data-HighwayNo
Supporting protocol for INTERBUSNo
Degree of protection (IP)IP66
Supporting protocol for CANYes
Supporting protocol for PROFIBUSNo
4-quadrant operation possibleNo
Mains frequency50/60 Hz
Mains voltage380 - 480V
Supporting protocol for INTERBUS-SafetyNo
Integrated breaking resistanceNo
Number of phases output3
Type of converterU converter
Number of interfaces PROFINET0
Number of phases input3
Max. output at linear load at rated output voltage1.5kW
Relative symmetric net frequency tolerance10%
Supporting protocol for PROFIsafeNo
Supporting protocol for AS-Interface Safety at WorkNo
Application in industrial area permittedYes
Supporting protocol for EtherNet/IPYes
Supporting protocol for PROFINET IONo
Nominal output current I2N4.1A
Relative symmetric net voltage tolerance10%
Application in domestic- and commercial area permittedYes
Supporting protocol for SafetyBUS pNo
Supporting protocol for Foundation FieldbusNo
Supporting protocol for PROFINET CBANo
Max. output voltage500V
Supporting protocol for DeviceNet SafetyNo
Max. output at quadratic load at rated output voltage1.5kW
Max. output frequency500Hz
Supporting protocol for BACnetNo
Degree of protection (NEMA)4X

Related products

*VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user

DC1-344D1FN-A66OE1

Main Product Image

Why Register?

  • View wholesale prices with discounts
  • Real-time stock availability
  • Access invoices and dispatch notes
  • Order history and frequently ordered items
  • Exclusive B2B offers

and much more...

Details

  • Low-voltage industrial components
  • Frequency converter =< 1 kV
  • 1 KOM
  • EATON

Technical specifications

Height

232mm

Width

161mm

Depth

162mm

Power consumption

66.5W

Number of HW-interfaces industrial Ethernet

0

Number of digital inputs

4

Number of analogue inputs

2

Number of digital outputs

1

Number of HW-interfaces RS-232

0

Number of analogue outputs

1

Supporting protocol for LON

With control element

Supporting protocol for ASI

With optical interface

Number of HW-interfaces other

0

Number of HW-interfaces RS-422

0

Supporting protocol for TCP/IP

Number of HW-interfaces serial TTY

0

Number of HW-interfaces USB

0

Supporting protocol for other bus systems

Supporting protocol for SUCONET

Supporting protocol for SERCOS

With PC connection

Number of HW-interfaces parallel

0

Supporting protocol for Modbus

Supporting protocol for DeviceNet

Supporting protocol for KNX

Number of HW-interfaces RS-485

1

Supporting protocol for Data-Highway

Supporting protocol for INTERBUS

Degree of protection (IP)

IP66

Supporting protocol for CAN

Supporting protocol for PROFIBUS

4-quadrant operation possible

Mains frequency

50/60 Hz

Mains voltage

380 .. 480V

Supporting protocol for INTERBUS-Safety

Integrated breaking resistance

Number of phases output

3

Type of converter

U converter

Number of interfaces PROFINET

0

Number of phases input

3

Max. output at linear load at rated output voltage

1.5kW

Relative symmetric net frequency tolerance

10%

Supporting protocol for PROFIsafe

Supporting protocol for AS-Interface Safety at Work

Application in industrial area permitted

Supporting protocol for EtherNet/IP

Supporting protocol for PROFINET IO

Nominal output current I2N

4.1A

Relative symmetric net voltage tolerance

10%

Application in domestic- and commercial area permitted

Supporting protocol for SafetyBUS p

Supporting protocol for Foundation Fieldbus

Supporting protocol for PROFINET CBA

Max. output voltage

500V

Supporting protocol for DeviceNet Safety

Max. output at quadratic load at rated output voltage

1.5kW

Max. output frequency

500Hz

Supporting protocol for BACnet

Degree of protection (NEMA)

4X

Related products

VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user.