Aleta.hr

Details

  • Low-voltage industrial components
  • Frequency converter =< 1 kV
  • 1 KOM
  • EATON

Technical specifications

Number of digital inputs4
Supporting protocol for LONNo
Number of digital outputs1
Number of HW-interfaces other0
Number of HW-interfaces RS-4851
Number of HW-interfaces serial TTY0
Power consumption63W
Number of HW-interfaces parallel0
Number of HW-interfaces RS-2320
Number of HW-interfaces RS-4220
Number of analogue inputs2
Height232mm
Depth162mm
Number of analogue outputs1
Number of HW-interfaces industrial Ethernet0
Width161mm
With control elementYes
Number of HW-interfaces USB0
Supporting protocol for ASINo
Supporting protocol for CANYes
Supporting protocol for TCP/IPNo
Supporting protocol for PROFIBUSNo
Supporting protocol for INTERBUSNo
Supporting protocol for ModbusYes
Supporting protocol for INTERBUS-SafetyNo
Degree of protection (IP)IP66
Supporting protocol for Data-HighwayNo
Number of phases input1
Mains voltage200 - 240V
Mains frequency50/60 Hz
4-quadrant operation possibleNo
Supporting protocol for DeviceNetNo
Supporting protocol for other bus systemsYes
With PC connectionYes
Number of interfaces PROFINET0
Supporting protocol for SERCOSNo
Supporting protocol for SUCONETNo
Integrated breaking resistanceNo
Type of converterU converter
With optical interfaceNo
Number of phases output1
Supporting protocol for KNXNo
Application in industrial area permittedYes
Supporting protocol for EtherNet/IPYes
Max. output frequency500Hz
Relative symmetric net voltage tolerance10%
Max. output at quadratic load at rated output voltage0.75kW
Max. output at linear load at rated output voltage0.75kW
Supporting protocol for DeviceNet SafetyNo
Application in domestic- and commercial area permittedYes
Supporting protocol for AS-Interface Safety at WorkNo
Relative symmetric net frequency tolerance10%
Supporting protocol for PROFINET CBANo
Degree of protection (NEMA)4X
Supporting protocol for BACnetNo
Max. output voltage250V
Supporting protocol for SafetyBUS pNo
Nominal output current I2N7A
Supporting protocol for Foundation FieldbusNo
Supporting protocol for PROFINET IONo
Supporting protocol for PROFIsafeNo

Related products

*VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user

DC1-S27D0FN-A66OE1

Main Product Image

Why Register?

  • View wholesale prices with discounts
  • Real-time stock availability
  • Access invoices and dispatch notes
  • Order history and frequently ordered items
  • Exclusive B2B offers

and much more...

Details

  • Low-voltage industrial components
  • Frequency converter =< 1 kV
  • 1 KOM
  • EATON

Technical specifications

Number of digital inputs

4

Supporting protocol for LON

Number of digital outputs

1

Number of HW-interfaces other

0

Number of HW-interfaces RS-485

1

Number of HW-interfaces serial TTY

0

Power consumption

63W

Number of HW-interfaces parallel

0

Number of HW-interfaces RS-232

0

Number of HW-interfaces RS-422

0

Number of analogue inputs

2

Height

232mm

Depth

162mm

Number of analogue outputs

1

Number of HW-interfaces industrial Ethernet

0

Width

161mm

With control element

Number of HW-interfaces USB

0

Supporting protocol for ASI

Supporting protocol for CAN

Supporting protocol for TCP/IP

Supporting protocol for PROFIBUS

Supporting protocol for INTERBUS

Supporting protocol for Modbus

Supporting protocol for INTERBUS-Safety

Degree of protection (IP)

IP66

Supporting protocol for Data-Highway

Number of phases input

1

Mains voltage

200 .. 240V

Mains frequency

50/60 Hz

4-quadrant operation possible

Supporting protocol for DeviceNet

Supporting protocol for other bus systems

With PC connection

Number of interfaces PROFINET

0

Supporting protocol for SERCOS

Supporting protocol for SUCONET

Integrated breaking resistance

Type of converter

U converter

With optical interface

Number of phases output

1

Supporting protocol for KNX

Application in industrial area permitted

Supporting protocol for EtherNet/IP

Max. output frequency

500Hz

Relative symmetric net voltage tolerance

10%

Max. output at quadratic load at rated output voltage

0.75kW

Max. output at linear load at rated output voltage

0.75kW

Supporting protocol for DeviceNet Safety

Application in domestic- and commercial area permitted

Supporting protocol for AS-Interface Safety at Work

Relative symmetric net frequency tolerance

10%

Supporting protocol for PROFINET CBA

Degree of protection (NEMA)

4X

Supporting protocol for BACnet

Max. output voltage

250V

Supporting protocol for SafetyBUS p

Nominal output current I2N

7A

Supporting protocol for Foundation Fieldbus

Supporting protocol for PROFINET IO

Supporting protocol for PROFIsafe

Related products