Aleta.hr

Details

  • Low-voltage industrial components
  • Frequency converter =< 1 kV
  • 1 KOM
  • EATON

Technical specifications

Width161mm
Supporting protocol for LONNo
Number of HW-interfaces RS-2320
Power consumption63W
Number of analogue outputs1
With control elementYes
Depth162mm
Number of HW-interfaces RS-4220
Number of digital outputs1
Number of HW-interfaces serial TTY0
Number of HW-interfaces industrial Ethernet0
Number of digital inputs4
Height232mm
Number of HW-interfaces RS-4851
Number of analogue inputs2
Number of HW-interfaces parallel0
With optical interfaceNo
Number of HW-interfaces other0
Number of HW-interfaces USB0
Supporting protocol for TCP/IPNo
Supporting protocol for ASINo
Supporting protocol for KNXNo
4-quadrant operation possibleNo
Supporting protocol for PROFIBUSNo
Supporting protocol for SERCOSNo
Supporting protocol for other bus systemsYes
Type of converterU converter
Integrated breaking resistanceNo
Number of phases input1
Number of phases output1
Supporting protocol for ModbusYes
Mains frequency50/60 Hz
Supporting protocol for INTERBUSNo
With PC connectionYes
Supporting protocol for INTERBUS-SafetyNo
Number of interfaces PROFINET0
Supporting protocol for CANYes
Supporting protocol for DeviceNetNo
Mains voltage200 - 240V
Degree of protection (IP)IP66
Supporting protocol for Data-HighwayNo
Application in industrial area permittedYes
Application in domestic- and commercial area permittedYes
Supporting protocol for SUCONETNo
Max. output at quadratic load at rated output voltage0.75kW
Supporting protocol for EtherNet/IPYes
Supporting protocol for PROFINET IONo
Supporting protocol for AS-Interface Safety at WorkNo
Max. output voltage250V
Supporting protocol for PROFIsafeNo
Supporting protocol for PROFINET CBANo
Relative symmetric net voltage tolerance10%
Supporting protocol for Foundation FieldbusNo
Max. output at linear load at rated output voltage0.75kW
Supporting protocol for SafetyBUS pNo
Relative symmetric net frequency tolerance10%
Degree of protection (NEMA)4X
Max. output frequency500Hz
Nominal output current I2N7A
Supporting protocol for BACnetNo
Supporting protocol for DeviceNet SafetyNo

Related products

*VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user

DC1-S27D0FN-A6SOE1

Main Product Image

Why Register?

  • View wholesale prices with discounts
  • Real-time stock availability
  • Access invoices and dispatch notes
  • Order history and frequently ordered items
  • Exclusive B2B offers

and much more...

Details

  • Low-voltage industrial components
  • Frequency converter =< 1 kV
  • 1 KOM
  • EATON

Technical specifications

Width

161mm

Supporting protocol for LON

Number of HW-interfaces RS-232

0

Power consumption

63W

Number of analogue outputs

1

With control element

Depth

162mm

Number of HW-interfaces RS-422

0

Number of digital outputs

1

Number of HW-interfaces serial TTY

0

Number of HW-interfaces industrial Ethernet

0

Number of digital inputs

4

Height

232mm

Number of HW-interfaces RS-485

1

Number of analogue inputs

2

Number of HW-interfaces parallel

0

With optical interface

Number of HW-interfaces other

0

Number of HW-interfaces USB

0

Supporting protocol for TCP/IP

Supporting protocol for ASI

Supporting protocol for KNX

4-quadrant operation possible

Supporting protocol for PROFIBUS

Supporting protocol for SERCOS

Supporting protocol for other bus systems

Type of converter

U converter

Integrated breaking resistance

Number of phases input

1

Number of phases output

1

Supporting protocol for Modbus

Mains frequency

50/60 Hz

Supporting protocol for INTERBUS

With PC connection

Supporting protocol for INTERBUS-Safety

Number of interfaces PROFINET

0

Supporting protocol for CAN

Supporting protocol for DeviceNet

Mains voltage

200 .. 240V

Degree of protection (IP)

IP66

Supporting protocol for Data-Highway

Application in industrial area permitted

Application in domestic- and commercial area permitted

Supporting protocol for SUCONET

Max. output at quadratic load at rated output voltage

0.75kW

Supporting protocol for EtherNet/IP

Supporting protocol for PROFINET IO

Supporting protocol for AS-Interface Safety at Work

Max. output voltage

250V

Supporting protocol for PROFIsafe

Supporting protocol for PROFINET CBA

Relative symmetric net voltage tolerance

10%

Supporting protocol for Foundation Fieldbus

Max. output at linear load at rated output voltage

0.75kW

Supporting protocol for SafetyBUS p

Relative symmetric net frequency tolerance

10%

Degree of protection (NEMA)

4X

Max. output frequency

500Hz

Nominal output current I2N

7A

Supporting protocol for BACnet

Supporting protocol for DeviceNet Safety

Related products

VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user.