Aleta.hr

Details

  • Low-voltage industrial components
  • Frequency converter =< 1 kV
  • 1 KOM
  • EATON

Technical specifications

Width167.8mm
Depth244.7mm
Height419mm
Power consumption229W
Number of analogue inputs2
With control elementYes
Supporting protocol for LONNo
Number of HW-interfaces parallel0
Number of digital outputs1
With optical interfaceNo
Number of HW-interfaces industrial Ethernet1
Number of HW-interfaces RS-4220
Number of analogue outputs2
Number of HW-interfaces RS-4851
Number of HW-interfaces serial TTY0
Supporting protocol for TCP/IPYes
Number of digital inputs8
Supporting protocol for KNXNo
Number of HW-interfaces USB0
Supporting protocol for PROFIBUSYes
Number of HW-interfaces RS-2320
Number of HW-interfaces other1
Supporting protocol for ASINo
Supporting protocol for INTERBUSNo
Supporting protocol for CANYes
Supporting protocol for Data-HighwayNo
Supporting protocol for SUCONETNo
Supporting protocol for DeviceNetYes
Supporting protocol for ModbusYes
Degree of protection (IP)IP54
Supporting protocol for other bus systemsYes
Supporting protocol for INTERBUS-SafetyNo
With PC connectionYes
Mains frequency50/60 Hz
Supporting protocol for SERCOSNo
Number of interfaces PROFINET0
4-quadrant operation possibleYes
Mains voltage208 - 240V
Type of converterU converter
Application in industrial area permittedYes
Max. output frequency400Hz
Number of phases output3
Supporting protocol for DeviceNet SafetyNo
Supporting protocol for AS-Interface Safety at WorkNo
Relative symmetric net voltage tolerance10%
Supporting protocol for Foundation FieldbusNo
Supporting protocol for EtherNet/IPYes
Relative symmetric net frequency tolerance10%
Supporting protocol for PROFINET CBANo
Number of phases input3
Max. output at quadratic load at rated output voltage5.5kW
Integrated breaking resistanceYes
Application in domestic- and commercial area permittedYes
Max. output at linear load at rated output voltage3.7kW
Supporting protocol for PROFIsafeNo
Supporting protocol for SafetyBUS pNo
Degree of protection (NEMA)12
Nominal output current I2N17.5A
Max. output voltage240V
Supporting protocol for PROFINET IOYes
Supporting protocol for BACnetYes

Related products

*VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user

DG1-32017FB-C54C

Main Product Image

Why Register?

  • View wholesale prices with discounts
  • Real-time stock availability
  • Access invoices and dispatch notes
  • Order history and frequently ordered items
  • Exclusive B2B offers

and much more...

Details

  • Low-voltage industrial components
  • Frequency converter =< 1 kV
  • 1 KOM
  • EATON

Technical specifications

Width

167.8mm

Depth

244.7mm

Height

419mm

Power consumption

229W

Number of analogue inputs

2

With control element

Supporting protocol for LON

Number of HW-interfaces parallel

0

Number of digital outputs

1

With optical interface

Number of HW-interfaces industrial Ethernet

1

Number of HW-interfaces RS-422

0

Number of analogue outputs

2

Number of HW-interfaces RS-485

1

Number of HW-interfaces serial TTY

0

Supporting protocol for TCP/IP

Number of digital inputs

8

Supporting protocol for KNX

Number of HW-interfaces USB

0

Supporting protocol for PROFIBUS

Number of HW-interfaces RS-232

0

Number of HW-interfaces other

1

Supporting protocol for ASI

Supporting protocol for INTERBUS

Supporting protocol for CAN

Supporting protocol for Data-Highway

Supporting protocol for SUCONET

Supporting protocol for DeviceNet

Supporting protocol for Modbus

Degree of protection (IP)

IP54

Supporting protocol for other bus systems

Supporting protocol for INTERBUS-Safety

With PC connection

Mains frequency

50/60 Hz

Supporting protocol for SERCOS

Number of interfaces PROFINET

0

4-quadrant operation possible

Mains voltage

208 .. 240V

Type of converter

U converter

Application in industrial area permitted

Max. output frequency

400Hz

Number of phases output

3

Supporting protocol for DeviceNet Safety

Supporting protocol for AS-Interface Safety at Work

Relative symmetric net voltage tolerance

10%

Supporting protocol for Foundation Fieldbus

Supporting protocol for EtherNet/IP

Relative symmetric net frequency tolerance

10%

Supporting protocol for PROFINET CBA

Number of phases input

3

Max. output at quadratic load at rated output voltage

5.5kW

Integrated breaking resistance

Application in domestic- and commercial area permitted

Max. output at linear load at rated output voltage

3.7kW

Supporting protocol for PROFIsafe

Supporting protocol for SafetyBUS p

Degree of protection (NEMA)

12

Nominal output current I2N

17.5A

Max. output voltage

240V

Supporting protocol for PROFINET IO

Supporting protocol for BACnet

Related products

VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user.