Aleta.hr

Details

  • Low-voltage industrial components
  • Frequency converter =< 1 kV
  • 1 KOM
  • EATON

Technical specifications

Number of digital inputs8
Number of HW-interfaces serial TTY0
Number of digital outputs1
Number of HW-interfaces industrial Ethernet1
Number of HW-interfaces other1
Number of analogue outputs2
Supporting protocol for LONNo
Number of HW-interfaces USB0
Number of analogue inputs2
Supporting protocol for TCP/IPYes
Supporting protocol for ASINo
Power consumption445W
Height558mm
Depth265.1mm
Number of HW-interfaces RS-2320
Number of HW-interfaces RS-4220
With optical interfaceNo
Number of HW-interfaces RS-4851
Width204.6mm
Number of HW-interfaces parallel0
With control elementYes
Supporting protocol for INTERBUSNo
Supporting protocol for Data-HighwayNo
Supporting protocol for CANYes
Supporting protocol for DeviceNetYes
Degree of protection (IP)IP54
Supporting protocol for KNXNo
Supporting protocol for SERCOSNo
Supporting protocol for other bus systemsYes
Supporting protocol for PROFIBUSYes
Supporting protocol for SUCONETNo
With PC connectionYes
Supporting protocol for ModbusYes
Mains voltage208 - 240V
Number of phases output3
4-quadrant operation possibleYes
Number of phases input3
Application in domestic- and commercial area permittedYes
Application in industrial area permittedYes
Type of converterU converter
Max. output frequency400Hz
Supporting protocol for INTERBUS-SafetyNo
Max. output at linear load at rated output voltage7.5kW
Mains frequency50/60 Hz
Number of interfaces PROFINET0
Integrated breaking resistanceYes
Supporting protocol for SafetyBUS pNo
Supporting protocol for PROFIsafeNo
Supporting protocol for DeviceNet SafetyNo
Max. output voltage240V
Supporting protocol for Foundation FieldbusNo
Nominal output current I2N31A
Relative symmetric net frequency tolerance10%
Supporting protocol for PROFINET CBANo
Relative symmetric net voltage tolerance10%
Supporting protocol for EtherNet/IPYes
Supporting protocol for BACnetYes
Supporting protocol for PROFINET IOYes
Supporting protocol for AS-Interface Safety at WorkNo
Max. output at quadratic load at rated output voltage11kW
Degree of protection (NEMA)12

Related products

*VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user

DG1-32031FB-C54C

Main Product Image

Why Register?

  • View wholesale prices with discounts
  • Real-time stock availability
  • Access invoices and dispatch notes
  • Order history and frequently ordered items
  • Exclusive B2B offers

and much more...

Details

  • Low-voltage industrial components
  • Frequency converter =< 1 kV
  • 1 KOM
  • EATON

Technical specifications

Number of digital inputs

8

Number of HW-interfaces serial TTY

0

Number of digital outputs

1

Number of HW-interfaces industrial Ethernet

1

Number of HW-interfaces other

1

Number of analogue outputs

2

Supporting protocol for LON

Number of HW-interfaces USB

0

Number of analogue inputs

2

Supporting protocol for TCP/IP

Supporting protocol for ASI

Power consumption

445W

Height

558mm

Depth

265.1mm

Number of HW-interfaces RS-232

0

Number of HW-interfaces RS-422

0

With optical interface

Number of HW-interfaces RS-485

1

Width

204.6mm

Number of HW-interfaces parallel

0

With control element

Supporting protocol for INTERBUS

Supporting protocol for Data-Highway

Supporting protocol for CAN

Supporting protocol for DeviceNet

Degree of protection (IP)

IP54

Supporting protocol for KNX

Supporting protocol for SERCOS

Supporting protocol for other bus systems

Supporting protocol for PROFIBUS

Supporting protocol for SUCONET

With PC connection

Supporting protocol for Modbus

Mains voltage

208 .. 240V

Number of phases output

3

4-quadrant operation possible

Number of phases input

3

Application in domestic- and commercial area permitted

Application in industrial area permitted

Type of converter

U converter

Max. output frequency

400Hz

Supporting protocol for INTERBUS-Safety

Max. output at linear load at rated output voltage

7.5kW

Mains frequency

50/60 Hz

Number of interfaces PROFINET

0

Integrated breaking resistance

Supporting protocol for SafetyBUS p

Supporting protocol for PROFIsafe

Supporting protocol for DeviceNet Safety

Max. output voltage

240V

Supporting protocol for Foundation Fieldbus

Nominal output current I2N

31A

Relative symmetric net frequency tolerance

10%

Supporting protocol for PROFINET CBA

Relative symmetric net voltage tolerance

10%

Supporting protocol for EtherNet/IP

Supporting protocol for BACnet

Supporting protocol for PROFINET IO

Supporting protocol for AS-Interface Safety at Work

Max. output at quadratic load at rated output voltage

11kW

Degree of protection (NEMA)

12

Related products