Aleta.hr

Details

  • Low-voltage industrial components
  • Frequency converter =< 1 kV
  • 1 KOM
  • EATON

Technical specifications

Width204.6mm
Power consumption602W
Depth265.1mm
Height558mm
Number of analogue outputs2
Number of analogue inputs2
Number of digital outputs1
With control elementYes
Number of HW-interfaces industrial Ethernet1
Number of HW-interfaces RS-4851
Supporting protocol for LONNo
Number of HW-interfaces RS-4220
Number of digital inputs8
Number of HW-interfaces RS-2320
Number of HW-interfaces other1
Supporting protocol for CANYes
Number of HW-interfaces parallel0
Number of HW-interfaces serial TTY0
Supporting protocol for PROFIBUSYes
With optical interfaceNo
Number of HW-interfaces USB0
Supporting protocol for TCP/IPYes
Supporting protocol for ASINo
Supporting protocol for DeviceNetYes
Supporting protocol for Data-HighwayNo
Supporting protocol for INTERBUSNo
With PC connectionYes
Supporting protocol for KNXNo
Supporting protocol for other bus systemsYes
Supporting protocol for SUCONETNo
Degree of protection (IP)IP54
Supporting protocol for SERCOSNo
Supporting protocol for ModbusYes
Mains voltage208 - 240V
Number of interfaces PROFINET0
Mains frequency50/60 Hz
Type of converterU converter
Supporting protocol for INTERBUS-SafetyNo
4-quadrant operation possibleYes
Number of phases input3
Integrated breaking resistanceYes
Max. output at linear load at rated output voltage11kW
Number of phases output3
Application in domestic- and commercial area permittedYes
Max. output frequency400Hz
Relative symmetric net voltage tolerance10%
Relative symmetric net frequency tolerance10%
Application in industrial area permittedYes
Max. output at quadratic load at rated output voltage15kW
Nominal output current I2N48A
Supporting protocol for BACnetYes
Supporting protocol for DeviceNet SafetyNo
Supporting protocol for PROFINET CBANo
Max. output voltage240V
Supporting protocol for Foundation FieldbusNo
Supporting protocol for PROFIsafeNo
Supporting protocol for AS-Interface Safety at WorkNo
Supporting protocol for EtherNet/IPYes
Supporting protocol for PROFINET IOYes
Supporting protocol for SafetyBUS pNo
Degree of protection (NEMA)12

Related products

*VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user

DG1-32048FB-C54C

Main Product Image

Why Register?

  • View wholesale prices with discounts
  • Real-time stock availability
  • Access invoices and dispatch notes
  • Order history and frequently ordered items
  • Exclusive B2B offers

and much more...

Details

  • Low-voltage industrial components
  • Frequency converter =< 1 kV
  • 1 KOM
  • EATON

Technical specifications

Width

204.6mm

Power consumption

602W

Depth

265.1mm

Height

558mm

Number of analogue outputs

2

Number of analogue inputs

2

Number of digital outputs

1

With control element

Number of HW-interfaces industrial Ethernet

1

Number of HW-interfaces RS-485

1

Supporting protocol for LON

Number of HW-interfaces RS-422

0

Number of digital inputs

8

Number of HW-interfaces RS-232

0

Number of HW-interfaces other

1

Supporting protocol for CAN

Number of HW-interfaces parallel

0

Number of HW-interfaces serial TTY

0

Supporting protocol for PROFIBUS

With optical interface

Number of HW-interfaces USB

0

Supporting protocol for TCP/IP

Supporting protocol for ASI

Supporting protocol for DeviceNet

Supporting protocol for Data-Highway

Supporting protocol for INTERBUS

With PC connection

Supporting protocol for KNX

Supporting protocol for other bus systems

Supporting protocol for SUCONET

Degree of protection (IP)

IP54

Supporting protocol for SERCOS

Supporting protocol for Modbus

Mains voltage

208 .. 240V

Number of interfaces PROFINET

0

Mains frequency

50/60 Hz

Type of converter

U converter

Supporting protocol for INTERBUS-Safety

4-quadrant operation possible

Number of phases input

3

Integrated breaking resistance

Max. output at linear load at rated output voltage

11kW

Number of phases output

3

Application in domestic- and commercial area permitted

Max. output frequency

400Hz

Relative symmetric net voltage tolerance

10%

Relative symmetric net frequency tolerance

10%

Application in industrial area permitted

Max. output at quadratic load at rated output voltage

15kW

Nominal output current I2N

48A

Supporting protocol for BACnet

Supporting protocol for DeviceNet Safety

Supporting protocol for PROFINET CBA

Max. output voltage

240V

Supporting protocol for Foundation Fieldbus

Supporting protocol for PROFIsafe

Supporting protocol for AS-Interface Safety at Work

Supporting protocol for EtherNet/IP

Supporting protocol for PROFINET IO

Supporting protocol for SafetyBUS p

Degree of protection (NEMA)

12