Aleta.hr

Details

  • Low-voltage industrial components
  • Frequency converter =< 1 kV
  • 1 KOM
  • EATON

Technical specifications

Power consumption689W
Width237.7mm
Depth294mm
Height630mm
Supporting protocol for LONNo
Number of analogue inputs2
With control elementYes
Number of HW-interfaces RS-4851
Number of HW-interfaces industrial Ethernet1
Number of HW-interfaces RS-4220
Number of digital outputs1
Number of digital inputs8
Number of HW-interfaces RS-2320
Number of analogue outputs2
Number of HW-interfaces serial TTY0
Number of HW-interfaces parallel0
With optical interfaceNo
Number of HW-interfaces USB0
Supporting protocol for TCP/IPYes
Supporting protocol for Data-HighwayNo
Supporting protocol for CANYes
Supporting protocol for PROFIBUSYes
Supporting protocol for ASINo
Number of HW-interfaces other1
Supporting protocol for DeviceNetYes
Supporting protocol for INTERBUSNo
Supporting protocol for ModbusYes
Supporting protocol for KNXNo
Supporting protocol for INTERBUS-SafetyNo
Supporting protocol for SERCOSNo
Degree of protection (IP)IP54
With PC connectionYes
Supporting protocol for SUCONETNo
Type of converterU converter
Mains frequency50/60 Hz
Number of interfaces PROFINET0
Supporting protocol for other bus systemsYes
Mains voltage208 - 240V
4-quadrant operation possibleYes
Number of phases input3
Relative symmetric net frequency tolerance10%
Max. output frequency400Hz
Integrated breaking resistanceYes
Max. output at linear load at rated output voltage15kW
Relative symmetric net voltage tolerance10%
Supporting protocol for AS-Interface Safety at WorkNo
Supporting protocol for EtherNet/IPYes
Application in domestic- and commercial area permittedYes
Max. output at quadratic load at rated output voltage18.5kW
Application in industrial area permittedYes
Supporting protocol for DeviceNet SafetyNo
Supporting protocol for PROFINET IOYes
Supporting protocol for Foundation FieldbusNo
Supporting protocol for PROFINET CBANo
Supporting protocol for PROFIsafeNo
Degree of protection (NEMA)12
Max. output voltage240V
Supporting protocol for SafetyBUS pNo
Number of phases output3
Supporting protocol for BACnetYes
Nominal output current I2N61A

Related products

*VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user

DG1-32061FB-C54C

Main Product Image

Why Register?

  • View wholesale prices with discounts
  • Real-time stock availability
  • Access invoices and dispatch notes
  • Order history and frequently ordered items
  • Exclusive B2B offers

and much more...

Details

  • Low-voltage industrial components
  • Frequency converter =< 1 kV
  • 1 KOM
  • EATON

Technical specifications

Power consumption

689W

Width

237.7mm

Depth

294mm

Height

630mm

Supporting protocol for LON

Number of analogue inputs

2

With control element

Number of HW-interfaces RS-485

1

Number of HW-interfaces industrial Ethernet

1

Number of HW-interfaces RS-422

0

Number of digital outputs

1

Number of digital inputs

8

Number of HW-interfaces RS-232

0

Number of analogue outputs

2

Number of HW-interfaces serial TTY

0

Number of HW-interfaces parallel

0

With optical interface

Number of HW-interfaces USB

0

Supporting protocol for TCP/IP

Supporting protocol for Data-Highway

Supporting protocol for CAN

Supporting protocol for PROFIBUS

Supporting protocol for ASI

Number of HW-interfaces other

1

Supporting protocol for DeviceNet

Supporting protocol for INTERBUS

Supporting protocol for Modbus

Supporting protocol for KNX

Supporting protocol for INTERBUS-Safety

Supporting protocol for SERCOS

Degree of protection (IP)

IP54

With PC connection

Supporting protocol for SUCONET

Type of converter

U converter

Mains frequency

50/60 Hz

Number of interfaces PROFINET

0

Supporting protocol for other bus systems

Mains voltage

208 .. 240V

4-quadrant operation possible

Number of phases input

3

Relative symmetric net frequency tolerance

10%

Max. output frequency

400Hz

Integrated breaking resistance

Max. output at linear load at rated output voltage

15kW

Relative symmetric net voltage tolerance

10%

Supporting protocol for AS-Interface Safety at Work

Supporting protocol for EtherNet/IP

Application in domestic- and commercial area permitted

Max. output at quadratic load at rated output voltage

18.5kW

Application in industrial area permitted

Supporting protocol for DeviceNet Safety

Supporting protocol for PROFINET IO

Supporting protocol for Foundation Fieldbus

Supporting protocol for PROFINET CBA

Supporting protocol for PROFIsafe

Degree of protection (NEMA)

12

Max. output voltage

240V

Supporting protocol for SafetyBUS p

Number of phases output

3

Supporting protocol for BACnet

Nominal output current I2N

61A

Related products

VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user.