Aleta.hr

Details

  • Low-voltage industrial components
  • Frequency converter =< 1 kV
  • 1 KOM
  • EATON

Technical specifications

With control elementYes
Number of HW-interfaces RS-4220
Number of HW-interfaces serial TTY0
Supporting protocol for LONNo
Height888.5mm
Number of HW-interfaces RS-2320
Number of HW-interfaces industrial Ethernet1
With optical interfaceNo
Depth340.7mm
Power consumption1077W
Number of HW-interfaces USB0
Number of HW-interfaces parallel0
Width288mm
Number of HW-interfaces other1
Supporting protocol for TCP/IPYes
Number of analogue inputs2
Number of digital inputs8
Number of analogue outputs2
Number of HW-interfaces RS-4851
Number of digital outputs1
Supporting protocol for ASINo
Supporting protocol for KNXNo
Type of converterU converter
Supporting protocol for other bus systemsYes
Supporting protocol for PROFIBUSYes
Integrated breaking resistanceYes
Supporting protocol for INTERBUS-SafetyNo
Supporting protocol for SERCOSNo
Supporting protocol for SUCONETNo
Number of phases input3
With PC connectionYes
Supporting protocol for CANYes
Supporting protocol for INTERBUSNo
Number of phases output3
Supporting protocol for ModbusYes
Mains frequency50/60 Hz
Supporting protocol for DeviceNetYes
Mains voltage208 - 240V
Number of interfaces PROFINET0
4-quadrant operation possibleYes
Supporting protocol for Data-HighwayNo
Degree of protection (IP)IP54
Application in domestic- and commercial area permittedYes
Application in industrial area permittedYes
Max. output at linear load at rated output voltage30kW
Max. output frequency400Hz
Max. output at quadratic load at rated output voltage37kW
Supporting protocol for PROFINET CBANo
Max. output voltage240V
Relative symmetric net voltage tolerance10%
Supporting protocol for SafetyBUS pNo
Supporting protocol for EtherNet/IPYes
Supporting protocol for BACnetYes
Supporting protocol for AS-Interface Safety at WorkNo
Supporting protocol for Foundation FieldbusNo
Relative symmetric net frequency tolerance10%
Degree of protection (NEMA)12
Supporting protocol for PROFIsafeNo
Nominal output current I2N114A
Supporting protocol for PROFINET IOYes
Supporting protocol for DeviceNet SafetyNo

Related products

*VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user

DG1-32114FB-C54C

Main Product Image

Why Register?

  • View wholesale prices with discounts
  • Real-time stock availability
  • Access invoices and dispatch notes
  • Order history and frequently ordered items
  • Exclusive B2B offers

and much more...

Details

  • Low-voltage industrial components
  • Frequency converter =< 1 kV
  • 1 KOM
  • EATON

Technical specifications

With control element

Number of HW-interfaces RS-422

0

Number of HW-interfaces serial TTY

0

Supporting protocol for LON

Height

888.5mm

Number of HW-interfaces RS-232

0

Number of HW-interfaces industrial Ethernet

1

With optical interface

Depth

340.7mm

Power consumption

1077W

Number of HW-interfaces USB

0

Number of HW-interfaces parallel

0

Width

288mm

Number of HW-interfaces other

1

Supporting protocol for TCP/IP

Number of analogue inputs

2

Number of digital inputs

8

Number of analogue outputs

2

Number of HW-interfaces RS-485

1

Number of digital outputs

1

Supporting protocol for ASI

Supporting protocol for KNX

Type of converter

U converter

Supporting protocol for other bus systems

Supporting protocol for PROFIBUS

Integrated breaking resistance

Supporting protocol for INTERBUS-Safety

Supporting protocol for SERCOS

Supporting protocol for SUCONET

Number of phases input

3

With PC connection

Supporting protocol for CAN

Supporting protocol for INTERBUS

Number of phases output

3

Supporting protocol for Modbus

Mains frequency

50/60 Hz

Supporting protocol for DeviceNet

Mains voltage

208 .. 240V

Number of interfaces PROFINET

0

4-quadrant operation possible

Supporting protocol for Data-Highway

Degree of protection (IP)

IP54

Application in domestic- and commercial area permitted

Application in industrial area permitted

Max. output at linear load at rated output voltage

30kW

Max. output frequency

400Hz

Max. output at quadratic load at rated output voltage

37kW

Supporting protocol for PROFINET CBA

Max. output voltage

240V

Relative symmetric net voltage tolerance

10%

Supporting protocol for SafetyBUS p

Supporting protocol for EtherNet/IP

Supporting protocol for BACnet

Supporting protocol for AS-Interface Safety at Work

Supporting protocol for Foundation Fieldbus

Relative symmetric net frequency tolerance

10%

Degree of protection (NEMA)

12

Supporting protocol for PROFIsafe

Nominal output current I2N

114A

Supporting protocol for PROFINET IO

Supporting protocol for DeviceNet Safety