Aleta.hr

Details

  • Low-voltage industrial components
  • Frequency converter =< 1 kV
  • 1 KOM
  • EATON

Technical specifications

Height888.5mm
Width288mm
Power consumption1077W
Number of digital inputs8
Depth340.7mm
Number of analogue inputs2
Supporting protocol for TCP/IPYes
Number of digital outputs1
Supporting protocol for ASINo
Number of HW-interfaces serial TTY0
Number of HW-interfaces parallel0
Supporting protocol for LONNo
Supporting protocol for PROFIBUSYes
Number of HW-interfaces RS-4851
Number of HW-interfaces USB0
Number of HW-interfaces RS-4220
With optical interfaceNo
Number of HW-interfaces RS-2320
Number of HW-interfaces other1
Number of analogue outputs2
Number of HW-interfaces industrial Ethernet1
With control elementYes
Supporting protocol for Data-HighwayNo
Supporting protocol for ModbusYes
Supporting protocol for CANYes
Supporting protocol for KNXNo
Supporting protocol for INTERBUSNo
With PC connectionYes
Supporting protocol for DeviceNetYes
Mains frequency50/60 Hz
Supporting protocol for SERCOSNo
Supporting protocol for SUCONETNo
Degree of protection (IP)IP21
Number of phases output3
Type of converterU converter
Max. output frequency400Hz
Integrated breaking resistanceNo
Max. output at linear load at rated output voltage30kW
4-quadrant operation possibleNo
Supporting protocol for other bus systemsYes
Number of phases input3
Max. output at quadratic load at rated output voltage37kW
Number of interfaces PROFINET0
Supporting protocol for INTERBUS-SafetyNo
Mains voltage208 - 240V
Relative symmetric net voltage tolerance10%
Application in industrial area permittedYes
Application in domestic- and commercial area permittedYes
Supporting protocol for EtherNet/IPYes
Relative symmetric net frequency tolerance10%
Supporting protocol for AS-Interface Safety at WorkNo
Supporting protocol for DeviceNet SafetyNo
Supporting protocol for PROFINET IOYes
Supporting protocol for Foundation FieldbusNo
Supporting protocol for PROFINET CBANo
Max. output voltage240V
Degree of protection (NEMA)1
Supporting protocol for SafetyBUS pNo
Nominal output current I2N114A
Supporting protocol for BACnetYes
Supporting protocol for PROFIsafeNo

Related products

*VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user

DG1-32114FN-C21C

Main Product Image

Why Register?

  • View wholesale prices with discounts
  • Real-time stock availability
  • Access invoices and dispatch notes
  • Order history and frequently ordered items
  • Exclusive B2B offers

and much more...

Details

  • Low-voltage industrial components
  • Frequency converter =< 1 kV
  • 1 KOM
  • EATON

Technical specifications

Height

888.5mm

Width

288mm

Power consumption

1077W

Number of digital inputs

8

Depth

340.7mm

Number of analogue inputs

2

Supporting protocol for TCP/IP

Number of digital outputs

1

Supporting protocol for ASI

Number of HW-interfaces serial TTY

0

Number of HW-interfaces parallel

0

Supporting protocol for LON

Supporting protocol for PROFIBUS

Number of HW-interfaces RS-485

1

Number of HW-interfaces USB

0

Number of HW-interfaces RS-422

0

With optical interface

Number of HW-interfaces RS-232

0

Number of HW-interfaces other

1

Number of analogue outputs

2

Number of HW-interfaces industrial Ethernet

1

With control element

Supporting protocol for Data-Highway

Supporting protocol for Modbus

Supporting protocol for CAN

Supporting protocol for KNX

Supporting protocol for INTERBUS

With PC connection

Supporting protocol for DeviceNet

Mains frequency

50/60 Hz

Supporting protocol for SERCOS

Supporting protocol for SUCONET

Degree of protection (IP)

IP21

Number of phases output

3

Type of converter

U converter

Max. output frequency

400Hz

Integrated breaking resistance

Max. output at linear load at rated output voltage

30kW

4-quadrant operation possible

Supporting protocol for other bus systems

Number of phases input

3

Max. output at quadratic load at rated output voltage

37kW

Number of interfaces PROFINET

0

Supporting protocol for INTERBUS-Safety

Mains voltage

208 .. 240V

Relative symmetric net voltage tolerance

10%

Application in industrial area permitted

Application in domestic- and commercial area permitted

Supporting protocol for EtherNet/IP

Relative symmetric net frequency tolerance

10%

Supporting protocol for AS-Interface Safety at Work

Supporting protocol for DeviceNet Safety

Supporting protocol for PROFINET IO

Supporting protocol for Foundation Fieldbus

Supporting protocol for PROFINET CBA

Max. output voltage

240V

Degree of protection (NEMA)

1

Supporting protocol for SafetyBUS p

Nominal output current I2N

114A

Supporting protocol for BACnet

Supporting protocol for PROFIsafe

Related products

VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user.