Aleta.hr

Details

  • Low-voltage industrial components
  • Frequency converter =< 1 kV
  • 1 KOM
  • EATON

Technical specifications

Power consumption1336W
Height888.5mm
Width288mm
Depth340.7mm
Number of analogue outputs2
Supporting protocol for LONNo
Number of digital outputs1
Supporting protocol for PROFIBUSYes
Number of HW-interfaces RS-4851
Number of digital inputs8
Number of HW-interfaces other1
Supporting protocol for ASINo
Supporting protocol for TCP/IPYes
Number of HW-interfaces RS-4220
With control elementYes
Number of HW-interfaces RS-2320
Number of HW-interfaces industrial Ethernet1
Number of HW-interfaces serial TTY0
Number of HW-interfaces parallel0
Number of HW-interfaces USB0
Number of analogue inputs2
Supporting protocol for SUCONETNo
Supporting protocol for Data-HighwayNo
Supporting protocol for INTERBUSNo
Supporting protocol for KNXNo
Supporting protocol for ModbusYes
Supporting protocol for DeviceNetYes
Supporting protocol for CANYes
With optical interfaceNo
Application in domestic- and commercial area permittedYes
Degree of protection (IP)IP21
Supporting protocol for other bus systemsYes
Relative symmetric net voltage tolerance10%
Max. output frequency400Hz
Mains frequency50/60 Hz
Type of converterU converter
Supporting protocol for INTERBUS-SafetyNo
Supporting protocol for SERCOSNo
Application in industrial area permittedYes
With PC connectionYes
Number of phases output3
Max. output at linear load at rated output voltage37kW
Max. output at quadratic load at rated output voltage45kW
Integrated breaking resistanceYes
Number of interfaces PROFINET0
Mains voltage208 - 240V
4-quadrant operation possibleYes
Supporting protocol for PROFINET CBANo
Supporting protocol for Foundation FieldbusNo
Supporting protocol for EtherNet/IPYes
Supporting protocol for DeviceNet SafetyNo
Relative symmetric net frequency tolerance10%
Supporting protocol for AS-Interface Safety at WorkNo
Number of phases input3
Supporting protocol for BACnetYes
Supporting protocol for PROFIsafeNo
Degree of protection (NEMA)1
Nominal output current I2N143A
Max. output voltage240V
Supporting protocol for SafetyBUS pNo
Supporting protocol for PROFINET IOYes

Related products

*VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user

DG1-32143FB-C21C

Main Product Image

Why Register?

  • View wholesale prices with discounts
  • Real-time stock availability
  • Access invoices and dispatch notes
  • Order history and frequently ordered items
  • Exclusive B2B offers

and much more...

Details

  • Low-voltage industrial components
  • Frequency converter =< 1 kV
  • 1 KOM
  • EATON

Technical specifications

Power consumption

1336W

Height

888.5mm

Width

288mm

Depth

340.7mm

Number of analogue outputs

2

Supporting protocol for LON

Number of digital outputs

1

Supporting protocol for PROFIBUS

Number of HW-interfaces RS-485

1

Number of digital inputs

8

Number of HW-interfaces other

1

Supporting protocol for ASI

Supporting protocol for TCP/IP

Number of HW-interfaces RS-422

0

With control element

Number of HW-interfaces RS-232

0

Number of HW-interfaces industrial Ethernet

1

Number of HW-interfaces serial TTY

0

Number of HW-interfaces parallel

0

Number of HW-interfaces USB

0

Number of analogue inputs

2

Supporting protocol for SUCONET

Supporting protocol for Data-Highway

Supporting protocol for INTERBUS

Supporting protocol for KNX

Supporting protocol for Modbus

Supporting protocol for DeviceNet

Supporting protocol for CAN

With optical interface

Application in domestic- and commercial area permitted

Degree of protection (IP)

IP21

Supporting protocol for other bus systems

Relative symmetric net voltage tolerance

10%

Max. output frequency

400Hz

Mains frequency

50/60 Hz

Type of converter

U converter

Supporting protocol for INTERBUS-Safety

Supporting protocol for SERCOS

Application in industrial area permitted

With PC connection

Number of phases output

3

Max. output at linear load at rated output voltage

37kW

Max. output at quadratic load at rated output voltage

45kW

Integrated breaking resistance

Number of interfaces PROFINET

0

Mains voltage

208 .. 240V

4-quadrant operation possible

Supporting protocol for PROFINET CBA

Supporting protocol for Foundation Fieldbus

Supporting protocol for EtherNet/IP

Supporting protocol for DeviceNet Safety

Relative symmetric net frequency tolerance

10%

Supporting protocol for AS-Interface Safety at Work

Number of phases input

3

Supporting protocol for BACnet

Supporting protocol for PROFIsafe

Degree of protection (NEMA)

1

Nominal output current I2N

143A

Max. output voltage

240V

Supporting protocol for SafetyBUS p

Supporting protocol for PROFINET IO

Related products

VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user.