Aleta.hr

Details

  • Low-voltage industrial components
  • Frequency converter =< 1 kV
  • 1 KOM
  • EATON

Technical specifications

Width288mm
Number of analogue outputs2
Number of digital outputs1
With control elementYes
Power consumption1336W
Supporting protocol for LONNo
Number of digital inputs8
Number of analogue inputs2
Depth340.7mm
Number of HW-interfaces RS-4851
Supporting protocol for INTERBUSNo
Supporting protocol for ModbusYes
Number of HW-interfaces other1
Supporting protocol for TCP/IPYes
Number of HW-interfaces industrial Ethernet1
Number of HW-interfaces serial TTY0
Number of HW-interfaces USB0
Supporting protocol for PROFIBUSYes
Supporting protocol for KNXNo
With optical interfaceNo
Number of HW-interfaces RS-2320
Number of HW-interfaces RS-4220
Number of HW-interfaces parallel0
Supporting protocol for ASINo
Height888.5mm
Supporting protocol for CANYes
Integrated breaking resistanceYes
Supporting protocol for INTERBUS-SafetyNo
With PC connectionYes
Supporting protocol for Data-HighwayNo
Type of converterU converter
Supporting protocol for SUCONETNo
Number of phases output3
Mains voltage208 - 240V
Application in industrial area permittedYes
Supporting protocol for other bus systemsYes
Number of phases input3
4-quadrant operation possibleYes
Supporting protocol for DeviceNetYes
Max. output at quadratic load at rated output voltage45kW
Mains frequency50/60 Hz
Degree of protection (IP)IP54
Max. output at linear load at rated output voltage37kW
Number of interfaces PROFINET0
Max. output frequency400Hz
Supporting protocol for SERCOSNo
Application in domestic- and commercial area permittedYes
Supporting protocol for AS-Interface Safety at WorkNo
Relative symmetric net voltage tolerance10%
Relative symmetric net frequency tolerance10%
Supporting protocol for DeviceNet SafetyNo
Supporting protocol for EtherNet/IPYes
Supporting protocol for PROFINET IOYes
Supporting protocol for Foundation FieldbusNo
Max. output voltage240V
Nominal output current I2N143A
Supporting protocol for PROFINET CBANo
Supporting protocol for SafetyBUS pNo
Degree of protection (NEMA)12
Supporting protocol for BACnetYes
Supporting protocol for PROFIsafeNo

Related products

*VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user

DG1-32143FB-C54C

Main Product Image

Why Register?

  • View wholesale prices with discounts
  • Real-time stock availability
  • Access invoices and dispatch notes
  • Order history and frequently ordered items
  • Exclusive B2B offers

and much more...

Details

  • Low-voltage industrial components
  • Frequency converter =< 1 kV
  • 1 KOM
  • EATON

Technical specifications

Width

288mm

Number of analogue outputs

2

Number of digital outputs

1

With control element

Power consumption

1336W

Supporting protocol for LON

Number of digital inputs

8

Number of analogue inputs

2

Depth

340.7mm

Number of HW-interfaces RS-485

1

Supporting protocol for INTERBUS

Supporting protocol for Modbus

Number of HW-interfaces other

1

Supporting protocol for TCP/IP

Number of HW-interfaces industrial Ethernet

1

Number of HW-interfaces serial TTY

0

Number of HW-interfaces USB

0

Supporting protocol for PROFIBUS

Supporting protocol for KNX

With optical interface

Number of HW-interfaces RS-232

0

Number of HW-interfaces RS-422

0

Number of HW-interfaces parallel

0

Supporting protocol for ASI

Height

888.5mm

Supporting protocol for CAN

Integrated breaking resistance

Supporting protocol for INTERBUS-Safety

With PC connection

Supporting protocol for Data-Highway

Type of converter

U converter

Supporting protocol for SUCONET

Number of phases output

3

Mains voltage

208 .. 240V

Application in industrial area permitted

Supporting protocol for other bus systems

Number of phases input

3

4-quadrant operation possible

Supporting protocol for DeviceNet

Max. output at quadratic load at rated output voltage

45kW

Mains frequency

50/60 Hz

Degree of protection (IP)

IP54

Max. output at linear load at rated output voltage

37kW

Number of interfaces PROFINET

0

Max. output frequency

400Hz

Supporting protocol for SERCOS

Application in domestic- and commercial area permitted

Supporting protocol for AS-Interface Safety at Work

Relative symmetric net voltage tolerance

10%

Relative symmetric net frequency tolerance

10%

Supporting protocol for DeviceNet Safety

Supporting protocol for EtherNet/IP

Supporting protocol for PROFINET IO

Supporting protocol for Foundation Fieldbus

Max. output voltage

240V

Nominal output current I2N

143A

Supporting protocol for PROFINET CBA

Supporting protocol for SafetyBUS p

Degree of protection (NEMA)

12

Supporting protocol for BACnet

Supporting protocol for PROFIsafe

Related products

VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user.