Aleta.hr

Details

  • Low-voltage industrial components
  • Frequency converter =< 1 kV
  • 1 KOM
  • EATON

Technical specifications

Height888.5mm
Width288mm
Power consumption1336W
Number of digital inputs8
Depth340.7mm
With control elementYes
Number of analogue inputs2
Number of analogue outputs2
Supporting protocol for LONNo
Number of digital outputs1
Number of HW-interfaces RS-2320
Number of HW-interfaces industrial Ethernet1
Number of HW-interfaces RS-4220
Number of HW-interfaces serial TTY0
Number of HW-interfaces other1
With optical interfaceNo
Number of HW-interfaces parallel0
Number of HW-interfaces RS-4851
Supporting protocol for ASINo
Number of HW-interfaces USB0
Supporting protocol for TCP/IPYes
Degree of protection (IP)IP54
Supporting protocol for ModbusYes
Supporting protocol for CANYes
Supporting protocol for SUCONETNo
Supporting protocol for PROFIBUSYes
Supporting protocol for other bus systemsYes
Supporting protocol for KNXNo
Supporting protocol for DeviceNetYes
Supporting protocol for Data-HighwayNo
Supporting protocol for INTERBUSNo
Supporting protocol for SERCOSNo
Mains voltage208 - 240V
Supporting protocol for INTERBUS-SafetyNo
Number of phases output3
Type of converterU converter
4-quadrant operation possibleNo
Mains frequency50/60 Hz
Number of interfaces PROFINET0
With PC connectionYes
Number of phases input3
Max. output frequency400Hz
Max. output at quadratic load at rated output voltage45kW
Max. output at linear load at rated output voltage37kW
Application in domestic- and commercial area permittedYes
Integrated breaking resistanceNo
Relative symmetric net frequency tolerance10%
Relative symmetric net voltage tolerance10%
Application in industrial area permittedYes
Supporting protocol for AS-Interface Safety at WorkNo
Supporting protocol for PROFINET CBANo
Supporting protocol for PROFIsafeNo
Supporting protocol for PROFINET IOYes
Supporting protocol for EtherNet/IPYes
Supporting protocol for DeviceNet SafetyNo
Supporting protocol for Foundation FieldbusNo
Supporting protocol for SafetyBUS pNo
Supporting protocol for BACnetYes
Nominal output current I2N143A
Degree of protection (NEMA)12
Max. output voltage240V

Related products

*VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user

DG1-32143FN-C54C

Main Product Image

Why Register?

  • View wholesale prices with discounts
  • Real-time stock availability
  • Access invoices and dispatch notes
  • Order history and frequently ordered items
  • Exclusive B2B offers

and much more...

Details

  • Low-voltage industrial components
  • Frequency converter =< 1 kV
  • 1 KOM
  • EATON

Technical specifications

Height

888.5mm

Width

288mm

Power consumption

1336W

Number of digital inputs

8

Depth

340.7mm

With control element

Number of analogue inputs

2

Number of analogue outputs

2

Supporting protocol for LON

Number of digital outputs

1

Number of HW-interfaces RS-232

0

Number of HW-interfaces industrial Ethernet

1

Number of HW-interfaces RS-422

0

Number of HW-interfaces serial TTY

0

Number of HW-interfaces other

1

With optical interface

Number of HW-interfaces parallel

0

Number of HW-interfaces RS-485

1

Supporting protocol for ASI

Number of HW-interfaces USB

0

Supporting protocol for TCP/IP

Degree of protection (IP)

IP54

Supporting protocol for Modbus

Supporting protocol for CAN

Supporting protocol for SUCONET

Supporting protocol for PROFIBUS

Supporting protocol for other bus systems

Supporting protocol for KNX

Supporting protocol for DeviceNet

Supporting protocol for Data-Highway

Supporting protocol for INTERBUS

Supporting protocol for SERCOS

Mains voltage

208 .. 240V

Supporting protocol for INTERBUS-Safety

Number of phases output

3

Type of converter

U converter

4-quadrant operation possible

Mains frequency

50/60 Hz

Number of interfaces PROFINET

0

With PC connection

Number of phases input

3

Max. output frequency

400Hz

Max. output at quadratic load at rated output voltage

45kW

Max. output at linear load at rated output voltage

37kW

Application in domestic- and commercial area permitted

Integrated breaking resistance

Relative symmetric net frequency tolerance

10%

Relative symmetric net voltage tolerance

10%

Application in industrial area permitted

Supporting protocol for AS-Interface Safety at Work

Supporting protocol for PROFINET CBA

Supporting protocol for PROFIsafe

Supporting protocol for PROFINET IO

Supporting protocol for EtherNet/IP

Supporting protocol for DeviceNet Safety

Supporting protocol for Foundation Fieldbus

Supporting protocol for SafetyBUS p

Supporting protocol for BACnet

Nominal output current I2N

143A

Degree of protection (NEMA)

12

Max. output voltage

240V

Related products