Technical specifications

Power consumption1724W
Height888.5mm
Number of digital inputs8
Width288mm
Depth340.7mm
With control elementYes
Supporting protocol for DeviceNetYes
Supporting protocol for INTERBUSNo
Supporting protocol for TCP/IPYes
Number of HW-interfaces RS-4851
Number of HW-interfaces RS-2320
Number of HW-interfaces industrial Ethernet1
Number of HW-interfaces other1
Number of HW-interfaces USB0
Supporting protocol for CANYes
Supporting protocol for PROFIBUSYes
Supporting protocol for ASINo
Number of HW-interfaces parallel0
With optical interfaceNo
Number of HW-interfaces RS-4220
Number of analogue inputs2
Number of analogue outputs2
Number of HW-interfaces serial TTY0
Supporting protocol for LONNo
Number of digital outputs1
Supporting protocol for ModbusYes
Supporting protocol for other bus systemsYes
Supporting protocol for SUCONETNo
Degree of protection (IP)IP54
Supporting protocol for KNXNo
Supporting protocol for Data-HighwayNo
Supporting protocol for INTERBUS-SafetyNo
Mains voltage208 - 240V
With PC connectionYes
Supporting protocol for AS-Interface Safety at WorkNo
Max. output at linear load at rated output voltage45kW
Supporting protocol for SERCOSNo
Number of phases input3
Max. output frequency400Hz
Relative symmetric net frequency tolerance10%
Max. output at quadratic load at rated output voltage55kW
Supporting protocol for DeviceNet SafetyNo
Number of phases output3
Application in domestic- and commercial area permittedYes
Relative symmetric net voltage tolerance10%
Application in industrial area permittedYes
4-quadrant operation possibleYes
Supporting protocol for PROFIsafeNo
Type of converterU converter
Number of interfaces PROFINET0
Mains frequency50/60 Hz
Integrated breaking resistanceYes
Supporting protocol for EtherNet/IPYes
Supporting protocol for PROFINET CBANo
Supporting protocol for Foundation FieldbusNo
Supporting protocol for PROFINET IOYes
Nominal output current I2N170A
Supporting protocol for BACnetYes
Max. output voltage240V
Supporting protocol for SafetyBUS pNo
Degree of protection (NEMA)12

Related products

*VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user

DG1-32170FB-C54C

Main Product Image

Why Register?

  • View wholesale prices with discounts
  • Real-time stock availability
  • Access invoices and dispatch notes
  • Order history and frequently ordered items
  • Exclusive B2B offers

and much more...

Details

  • Low-voltage industrial components
  • Frequency converter =< 1 kV
  • 1 KOM
  • EATON

Technical specifications

Power consumption

1724W

Height

888.5mm

Number of digital inputs

8

Width

288mm

Depth

340.7mm

With control element

Supporting protocol for DeviceNet

Supporting protocol for INTERBUS

Supporting protocol for TCP/IP

Number of HW-interfaces RS-485

1

Number of HW-interfaces RS-232

0

Number of HW-interfaces industrial Ethernet

1

Number of HW-interfaces other

1

Number of HW-interfaces USB

0

Supporting protocol for CAN

Supporting protocol for PROFIBUS

Supporting protocol for ASI

Number of HW-interfaces parallel

0

With optical interface

Number of HW-interfaces RS-422

0

Number of analogue inputs

2

Number of analogue outputs

2

Number of HW-interfaces serial TTY

0

Supporting protocol for LON

Number of digital outputs

1

Supporting protocol for Modbus

Supporting protocol for other bus systems

Supporting protocol for SUCONET

Degree of protection (IP)

IP54

Supporting protocol for KNX

Supporting protocol for Data-Highway

Supporting protocol for INTERBUS-Safety

Mains voltage

208 .. 240V

With PC connection

Supporting protocol for AS-Interface Safety at Work

Max. output at linear load at rated output voltage

45kW

Supporting protocol for SERCOS

Number of phases input

3

Max. output frequency

400Hz

Relative symmetric net frequency tolerance

10%

Max. output at quadratic load at rated output voltage

55kW

Supporting protocol for DeviceNet Safety

Number of phases output

3

Application in domestic- and commercial area permitted

Relative symmetric net voltage tolerance

10%

Application in industrial area permitted

4-quadrant operation possible

Supporting protocol for PROFIsafe

Type of converter

U converter

Number of interfaces PROFINET

0

Mains frequency

50/60 Hz

Integrated breaking resistance

Supporting protocol for EtherNet/IP

Supporting protocol for PROFINET CBA

Supporting protocol for Foundation Fieldbus

Supporting protocol for PROFINET IO

Nominal output current I2N

170A

Supporting protocol for BACnet

Max. output voltage

240V

Supporting protocol for SafetyBUS p

Degree of protection (NEMA)

12