Aleta.hr

Details

  • Low-voltage industrial components
  • Frequency converter =< 1 kV
  • 1 KOM
  • EATON

Technical specifications

Width288mm
Height888.5mm
With control elementYes
Number of digital outputs1
Number of digital inputs8
Power consumption1724W
Depth340.7mm
Number of analogue inputs2
Number of HW-interfaces industrial Ethernet1
Supporting protocol for PROFIBUSYes
Supporting protocol for KNXNo
Number of HW-interfaces other1
Supporting protocol for ModbusYes
Supporting protocol for INTERBUSNo
Number of HW-interfaces RS-2320
Number of HW-interfaces parallel0
Number of analogue outputs2
Supporting protocol for CANYes
Supporting protocol for TCP/IPYes
Number of HW-interfaces USB0
Number of HW-interfaces RS-4851
Supporting protocol for ASINo
Number of HW-interfaces RS-4220
With optical interfaceNo
Number of HW-interfaces serial TTY0
Supporting protocol for LONNo
With PC connectionYes
Supporting protocol for DeviceNetYes
Supporting protocol for Data-HighwayNo
Supporting protocol for SUCONETNo
Degree of protection (IP)IP21
Supporting protocol for other bus systemsYes
Type of converterU converter
Relative symmetric net voltage tolerance10%
Supporting protocol for INTERBUS-SafetyNo
Mains voltage208 - 240V
Mains frequency50/60 Hz
Supporting protocol for SERCOSNo
Max. output frequency400Hz
Application in domestic- and commercial area permittedYes
4-quadrant operation possibleNo
Relative symmetric net frequency tolerance10%
Application in industrial area permittedYes
Integrated breaking resistanceNo
Number of phases output3
Max. output at quadratic load at rated output voltage55kW
Max. output at linear load at rated output voltage45kW
Number of interfaces PROFINET0
Number of phases input3
Supporting protocol for DeviceNet SafetyNo
Supporting protocol for SafetyBUS pNo
Supporting protocol for Foundation FieldbusNo
Supporting protocol for AS-Interface Safety at WorkNo
Supporting protocol for PROFINET IOYes
Supporting protocol for PROFIsafeNo
Supporting protocol for EtherNet/IPYes
Supporting protocol for PROFINET CBANo
Max. output voltage240V
Degree of protection (NEMA)1
Supporting protocol for BACnetYes
Nominal output current I2N170A

Related products

*VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user

DG1-32170FN-C21C

Main Product Image

Why Register?

  • View wholesale prices with discounts
  • Real-time stock availability
  • Access invoices and dispatch notes
  • Order history and frequently ordered items
  • Exclusive B2B offers

and much more...

Details

  • Low-voltage industrial components
  • Frequency converter =< 1 kV
  • 1 KOM
  • EATON

Technical specifications

Width

288mm

Height

888.5mm

With control element

Number of digital outputs

1

Number of digital inputs

8

Power consumption

1724W

Depth

340.7mm

Number of analogue inputs

2

Number of HW-interfaces industrial Ethernet

1

Supporting protocol for PROFIBUS

Supporting protocol for KNX

Number of HW-interfaces other

1

Supporting protocol for Modbus

Supporting protocol for INTERBUS

Number of HW-interfaces RS-232

0

Number of HW-interfaces parallel

0

Number of analogue outputs

2

Supporting protocol for CAN

Supporting protocol for TCP/IP

Number of HW-interfaces USB

0

Number of HW-interfaces RS-485

1

Supporting protocol for ASI

Number of HW-interfaces RS-422

0

With optical interface

Number of HW-interfaces serial TTY

0

Supporting protocol for LON

With PC connection

Supporting protocol for DeviceNet

Supporting protocol for Data-Highway

Supporting protocol for SUCONET

Degree of protection (IP)

IP21

Supporting protocol for other bus systems

Type of converter

U converter

Relative symmetric net voltage tolerance

10%

Supporting protocol for INTERBUS-Safety

Mains voltage

208 .. 240V

Mains frequency

50/60 Hz

Supporting protocol for SERCOS

Max. output frequency

400Hz

Application in domestic- and commercial area permitted

4-quadrant operation possible

Relative symmetric net frequency tolerance

10%

Application in industrial area permitted

Integrated breaking resistance

Number of phases output

3

Max. output at quadratic load at rated output voltage

55kW

Max. output at linear load at rated output voltage

45kW

Number of interfaces PROFINET

0

Number of phases input

3

Supporting protocol for DeviceNet Safety

Supporting protocol for SafetyBUS p

Supporting protocol for Foundation Fieldbus

Supporting protocol for AS-Interface Safety at Work

Supporting protocol for PROFINET IO

Supporting protocol for PROFIsafe

Supporting protocol for EtherNet/IP

Supporting protocol for PROFINET CBA

Max. output voltage

240V

Degree of protection (NEMA)

1

Supporting protocol for BACnet

Nominal output current I2N

170A

Related products