Aleta.hr

Details

  • Low-voltage industrial components
  • Frequency converter =< 1 kV
  • 1 KOM
  • EATON

Technical specifications

Supporting protocol for LONNo
Number of analogue inputs2
Power consumption1724W
Height888.5mm
With control elementYes
Width288mm
Number of digital outputs1
Depth340.7mm
Number of analogue outputs2
Number of digital inputs8
Number of HW-interfaces RS-4220
Number of HW-interfaces RS-2320
Number of HW-interfaces industrial Ethernet1
Number of HW-interfaces serial TTY0
Number of HW-interfaces USB0
Supporting protocol for DeviceNetYes
With PC connectionYes
Supporting protocol for SUCONETNo
Supporting protocol for other bus systemsYes
Degree of protection (IP)IP54
Supporting protocol for INTERBUSNo
Supporting protocol for PROFIBUSYes
Supporting protocol for ModbusYes
Supporting protocol for Data-HighwayNo
Number of HW-interfaces RS-4851
Supporting protocol for TCP/IPYes
With optical interfaceNo
Supporting protocol for CANYes
Number of HW-interfaces other1
Supporting protocol for KNXNo
Supporting protocol for ASINo
Number of HW-interfaces parallel0
4-quadrant operation possibleNo
Mains frequency50/60 Hz
Supporting protocol for SERCOSNo
Supporting protocol for INTERBUS-SafetyNo
Number of interfaces PROFINET0
Mains voltage208 - 240V
Application in domestic- and commercial area permittedYes
Application in industrial area permittedYes
Type of converterU converter
Number of phases output3
Supporting protocol for PROFINET IOYes
Integrated breaking resistanceNo
Max. output at quadratic load at rated output voltage55kW
Supporting protocol for PROFINET CBANo
Supporting protocol for EtherNet/IPYes
Supporting protocol for DeviceNet SafetyNo
Number of phases input3
Relative symmetric net voltage tolerance10%
Supporting protocol for Foundation FieldbusNo
Relative symmetric net frequency tolerance10%
Max. output at linear load at rated output voltage45kW
Max. output frequency400Hz
Supporting protocol for AS-Interface Safety at WorkNo
Supporting protocol for BACnetYes
Supporting protocol for PROFIsafeNo
Nominal output current I2N170A
Degree of protection (NEMA)12
Supporting protocol for SafetyBUS pNo
Max. output voltage240V

Related products

*VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user

DG1-32170FN-C54C

Main Product Image

Why Register?

  • View wholesale prices with discounts
  • Real-time stock availability
  • Access invoices and dispatch notes
  • Order history and frequently ordered items
  • Exclusive B2B offers

and much more...

Details

  • Low-voltage industrial components
  • Frequency converter =< 1 kV
  • 1 KOM
  • EATON

Technical specifications

Supporting protocol for LON

Number of analogue inputs

2

Power consumption

1724W

Height

888.5mm

With control element

Width

288mm

Number of digital outputs

1

Depth

340.7mm

Number of analogue outputs

2

Number of digital inputs

8

Number of HW-interfaces RS-422

0

Number of HW-interfaces RS-232

0

Number of HW-interfaces industrial Ethernet

1

Number of HW-interfaces serial TTY

0

Number of HW-interfaces USB

0

Supporting protocol for DeviceNet

With PC connection

Supporting protocol for SUCONET

Supporting protocol for other bus systems

Degree of protection (IP)

IP54

Supporting protocol for INTERBUS

Supporting protocol for PROFIBUS

Supporting protocol for Modbus

Supporting protocol for Data-Highway

Number of HW-interfaces RS-485

1

Supporting protocol for TCP/IP

With optical interface

Supporting protocol for CAN

Number of HW-interfaces other

1

Supporting protocol for KNX

Supporting protocol for ASI

Number of HW-interfaces parallel

0

4-quadrant operation possible

Mains frequency

50/60 Hz

Supporting protocol for SERCOS

Supporting protocol for INTERBUS-Safety

Number of interfaces PROFINET

0

Mains voltage

208 .. 240V

Application in domestic- and commercial area permitted

Application in industrial area permitted

Type of converter

U converter

Number of phases output

3

Supporting protocol for PROFINET IO

Integrated breaking resistance

Max. output at quadratic load at rated output voltage

55kW

Supporting protocol for PROFINET CBA

Supporting protocol for EtherNet/IP

Supporting protocol for DeviceNet Safety

Number of phases input

3

Relative symmetric net voltage tolerance

10%

Supporting protocol for Foundation Fieldbus

Relative symmetric net frequency tolerance

10%

Max. output at linear load at rated output voltage

45kW

Max. output frequency

400Hz

Supporting protocol for AS-Interface Safety at Work

Supporting protocol for BACnet

Supporting protocol for PROFIsafe

Nominal output current I2N

170A

Degree of protection (NEMA)

12

Supporting protocol for SafetyBUS p

Max. output voltage

240V

Related products

VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user.