Aleta.hr

Details

  • Low-voltage industrial components
  • Frequency converter =< 1 kV
  • 1 KOM
  • EATON

Technical specifications

Number of digital outputs1
Number of HW-interfaces RS-4851
Number of analogue outputs2
Number of HW-interfaces serial TTY0
Number of HW-interfaces RS-4220
Number of digital inputs8
Number of HW-interfaces other1
Depth371mm
Number of HW-interfaces parallel0
With control elementYes
Height486mm
Number of analogue inputs2
Width1035mm
Number of HW-interfaces USB0
Supporting protocol for LONNo
Number of HW-interfaces RS-2320
Number of HW-interfaces industrial Ethernet1
Supporting protocol for TCP/IPYes
With optical interfaceNo
Supporting protocol for other bus systemsYes
Degree of protection (IP)IP54
With PC connectionYes
Number of phases output3
Supporting protocol for Data-HighwayNo
Number of phases input3
Supporting protocol for ASINo
Supporting protocol for INTERBUS-SafetyNo
Supporting protocol for DeviceNetYes
Supporting protocol for INTERBUSNo
Supporting protocol for CANYes
Supporting protocol for ModbusYes
Application in industrial area permittedYes
Mains frequency50/60 Hz
Supporting protocol for SUCONETNo
Number of interfaces PROFINET0
Supporting protocol for SERCOSNo
Supporting protocol for KNXNo
Integrated breaking resistanceNo
Mains voltage177 - 264V
Max. output frequency400Hz
Application in domestic- and commercial area permittedYes
Supporting protocol for PROFIBUSYes
4-quadrant operation possibleYes
Type of converterU converter
Max. output at linear load at rated output voltage55kW
Supporting protocol for PROFINET IONo
Relative symmetric net frequency tolerance10%
Supporting protocol for PROFIsafeNo
Degree of protection (NEMA)12
Supporting protocol for DeviceNet SafetyNo
Supporting protocol for EtherNet/IPYes
Relative symmetric net voltage tolerance10%
Supporting protocol for BACnetYes
Nominal output current I2N261A
Supporting protocol for AS-Interface Safety at WorkNo
Supporting protocol for PROFINET CBANo
Max. output voltage240V
Max. output at quadratic load at rated output voltage75kW
Supporting protocol for Foundation FieldbusNo
Supporting protocol for SafetyBUS pNo

Related products

*VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user

DG1-32211FN-C54C

Main Product Image

Why Register?

  • View wholesale prices with discounts
  • Real-time stock availability
  • Access invoices and dispatch notes
  • Order history and frequently ordered items
  • Exclusive B2B offers

and much more...

Details

  • Low-voltage industrial components
  • Frequency converter =< 1 kV
  • 1 KOM
  • EATON

Technical specifications

Number of digital outputs

1

Number of HW-interfaces RS-485

1

Number of analogue outputs

2

Number of HW-interfaces serial TTY

0

Number of HW-interfaces RS-422

0

Number of digital inputs

8

Number of HW-interfaces other

1

Depth

371mm

Number of HW-interfaces parallel

0

With control element

Height

486mm

Number of analogue inputs

2

Width

1035mm

Number of HW-interfaces USB

0

Supporting protocol for LON

Number of HW-interfaces RS-232

0

Number of HW-interfaces industrial Ethernet

1

Supporting protocol for TCP/IP

With optical interface

Supporting protocol for other bus systems

Degree of protection (IP)

IP54

With PC connection

Number of phases output

3

Supporting protocol for Data-Highway

Number of phases input

3

Supporting protocol for ASI

Supporting protocol for INTERBUS-Safety

Supporting protocol for DeviceNet

Supporting protocol for INTERBUS

Supporting protocol for CAN

Supporting protocol for Modbus

Application in industrial area permitted

Mains frequency

50/60 Hz

Supporting protocol for SUCONET

Number of interfaces PROFINET

0

Supporting protocol for SERCOS

Supporting protocol for KNX

Integrated breaking resistance

Mains voltage

177 .. 264V

Max. output frequency

400Hz

Application in domestic- and commercial area permitted

Supporting protocol for PROFIBUS

4-quadrant operation possible

Type of converter

U converter

Max. output at linear load at rated output voltage

55kW

Supporting protocol for PROFINET IO

Relative symmetric net frequency tolerance

10%

Supporting protocol for PROFIsafe

Degree of protection (NEMA)

12

Supporting protocol for DeviceNet Safety

Supporting protocol for EtherNet/IP

Relative symmetric net voltage tolerance

10%

Supporting protocol for BACnet

Nominal output current I2N

261A

Supporting protocol for AS-Interface Safety at Work

Supporting protocol for PROFINET CBA

Max. output voltage

240V

Max. output at quadratic load at rated output voltage

75kW

Supporting protocol for Foundation Fieldbus

Supporting protocol for SafetyBUS p

Related products

VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user.