  • Low-voltage industrial components
  • Frequency converter =< 1 kV
  • 1 KOM
  • EATON

Technical specifications

With control elementYes
Width1035mm
Number of HW-interfaces serial TTY0
Number of HW-interfaces industrial Ethernet1
Number of HW-interfaces RS-2320
Number of digital outputs1
Height486mm
Number of analogue inputs2
Number of analogue outputs2
Number of digital inputs8
Depth371mm
Number of HW-interfaces RS-4220
Number of HW-interfaces RS-4851
Supporting protocol for LONNo
Number of HW-interfaces other1
Number of HW-interfaces USB0
Number of HW-interfaces parallel0
Supporting protocol for ASINo
Supporting protocol for CANYes
Supporting protocol for PROFIBUSYes
Supporting protocol for TCP/IPYes
With optical interfaceNo
Supporting protocol for DeviceNetYes
Supporting protocol for ModbusYes
Number of phases input3
Mains frequency50/60 Hz
Supporting protocol for KNXNo
With PC connectionYes
Supporting protocol for SERCOSNo
Degree of protection (IP)IP54
Supporting protocol for INTERBUSNo
4-quadrant operation possibleYes
Application in domestic- and commercial area permittedYes
Supporting protocol for SUCONETNo
Number of phases output3
Integrated breaking resistanceNo
Mains voltage177 - 264V
Supporting protocol for other bus systemsYes
Application in industrial area permittedYes
Type of converterU converter
Supporting protocol for Data-HighwayNo
Supporting protocol for INTERBUS-SafetyNo
Number of interfaces PROFINET0
Max. output at quadratic load at rated output voltage90kW
Max. output at linear load at rated output voltage75kW
Max. output frequency400Hz
Relative symmetric net voltage tolerance10%
Supporting protocol for EtherNet/IPYes
Supporting protocol for SafetyBUS pNo
Relative symmetric net frequency tolerance10%
Supporting protocol for DeviceNet SafetyNo
Supporting protocol for PROFIsafeNo
Degree of protection (NEMA)12
Supporting protocol for Foundation FieldbusNo
Nominal output current I2N312A
Supporting protocol for AS-Interface Safety at WorkNo
Supporting protocol for BACnetYes
Supporting protocol for PROFINET IONo
Max. output voltage240V
Supporting protocol for PROFINET CBANo

Related products

*VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user

DG1-32248FN-C54C

Main Product Image

Why Register?

  • View wholesale prices with discounts
  • Real-time stock availability
  • Access invoices and dispatch notes
  • Order history and frequently ordered items
  • Exclusive B2B offers

and much more...

Details

  • Low-voltage industrial components
  • Frequency converter =< 1 kV
  • 1 KOM
  • EATON

Technical specifications

With control element

Width

1035mm

Number of HW-interfaces serial TTY

0

Number of HW-interfaces industrial Ethernet

1

Number of HW-interfaces RS-232

0

Number of digital outputs

1

Height

486mm

Number of analogue inputs

2

Number of analogue outputs

2

Number of digital inputs

8

Depth

371mm

Number of HW-interfaces RS-422

0

Number of HW-interfaces RS-485

1

Supporting protocol for LON

Number of HW-interfaces other

1

Number of HW-interfaces USB

0

Number of HW-interfaces parallel

0

Supporting protocol for ASI

Supporting protocol for CAN

Supporting protocol for PROFIBUS

Supporting protocol for TCP/IP

With optical interface

Supporting protocol for DeviceNet

Supporting protocol for Modbus

Number of phases input

3

Mains frequency

50/60 Hz

Supporting protocol for KNX

With PC connection

Supporting protocol for SERCOS

Degree of protection (IP)

IP54

Supporting protocol for INTERBUS

4-quadrant operation possible

Application in domestic- and commercial area permitted

Supporting protocol for SUCONET

Number of phases output

3

Integrated breaking resistance

Mains voltage

177 .. 264V

Supporting protocol for other bus systems

Application in industrial area permitted

Type of converter

U converter

Supporting protocol for Data-Highway

Supporting protocol for INTERBUS-Safety

Number of interfaces PROFINET

0

Max. output at quadratic load at rated output voltage

90kW

Max. output at linear load at rated output voltage

75kW

Max. output frequency

400Hz

Relative symmetric net voltage tolerance

10%

Supporting protocol for EtherNet/IP

Supporting protocol for SafetyBUS p

Relative symmetric net frequency tolerance

10%

Supporting protocol for DeviceNet Safety

Supporting protocol for PROFIsafe

Degree of protection (NEMA)

12

Supporting protocol for Foundation Fieldbus

Nominal output current I2N

312A

Supporting protocol for AS-Interface Safety at Work

Supporting protocol for BACnet

Supporting protocol for PROFINET IO

Max. output voltage

240V

Supporting protocol for PROFINET CBA

Related products