Aleta.hr

Details

  • Low-voltage industrial components
  • Frequency converter =< 1 kV
  • 1 KOM
  • EATON

Technical specifications

Number of digital outputs1
Number of HW-interfaces industrial Ethernet1
Number of HW-interfaces RS-4220
Depth173.5mm
Width127mm
Number of HW-interfaces parallel0
Number of HW-interfaces serial TTY0
Number of HW-interfaces RS-4851
Number of analogue inputs2
Number of HW-interfaces RS-2320
Number of HW-interfaces USB0
Supporting protocol for LONNo
Number of digital inputs8
Number of HW-interfaces other1
Number of analogue outputs2
With control elementYes
Height268.7mm
Power consumption53W
Supporting protocol for TCP/IPYes
With optical interfaceNo
Supporting protocol for ASINo
Supporting protocol for PROFIBUSYes
Supporting protocol for KNXNo
Supporting protocol for INTERBUSNo
4-quadrant operation possibleYes
Number of phases output3
Supporting protocol for CANYes
Mains frequency50/60 Hz
Supporting protocol for other bus systemsYes
Type of converterU converter
Degree of protection (IP)IP20
Supporting protocol for DeviceNetYes
Number of phases input3
Mains voltage208 - 240V
Supporting protocol for SUCONETNo
Supporting protocol for INTERBUS-SafetyNo
Integrated breaking resistanceYes
Number of interfaces PROFINET0
Supporting protocol for Data-HighwayNo
Supporting protocol for ModbusYes
With PC connectionYes
Supporting protocol for SERCOSNo
Max. output at linear load at rated output voltage0.55kW
Application in domestic- and commercial area permittedYes
Application in industrial area permittedYes
Max. output frequency400Hz
Relative symmetric net frequency tolerance10%
Supporting protocol for AS-Interface Safety at WorkNo
Max. output at quadratic load at rated output voltage0.75kW
Max. output voltage240V
Supporting protocol for BACnetYes
Relative symmetric net voltage tolerance10%
Supporting protocol for EtherNet/IPYes
Supporting protocol for PROFINET IOYes
Supporting protocol for PROFINET CBANo
Degree of protection (NEMA)Other
Supporting protocol for DeviceNet SafetyNo
Supporting protocol for PROFIsafeNo
Supporting protocol for Foundation FieldbusNo
Supporting protocol for SafetyBUS pNo
Nominal output current I2N3.7A

Related products

*VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user

DG1-323D7EB-C20C

Main Product Image

Why Register?

  • View wholesale prices with discounts
  • Real-time stock availability
  • Access invoices and dispatch notes
  • Order history and frequently ordered items
  • Exclusive B2B offers

and much more...

Details

  • Low-voltage industrial components
  • Frequency converter =< 1 kV
  • 1 KOM
  • EATON

Technical specifications

Number of digital outputs

1

Number of HW-interfaces industrial Ethernet

1

Number of HW-interfaces RS-422

0

Depth

173.5mm

Width

127mm

Number of HW-interfaces parallel

0

Number of HW-interfaces serial TTY

0

Number of HW-interfaces RS-485

1

Number of analogue inputs

2

Number of HW-interfaces RS-232

0

Number of HW-interfaces USB

0

Supporting protocol for LON

Number of digital inputs

8

Number of HW-interfaces other

1

Number of analogue outputs

2

With control element

Height

268.7mm

Power consumption

53W

Supporting protocol for TCP/IP

With optical interface

Supporting protocol for ASI

Supporting protocol for PROFIBUS

Supporting protocol for KNX

Supporting protocol for INTERBUS

4-quadrant operation possible

Number of phases output

3

Supporting protocol for CAN

Mains frequency

50/60 Hz

Supporting protocol for other bus systems

Type of converter

U converter

Degree of protection (IP)

IP20

Supporting protocol for DeviceNet

Number of phases input

3

Mains voltage

208 .. 240V

Supporting protocol for SUCONET

Supporting protocol for INTERBUS-Safety

Integrated breaking resistance

Number of interfaces PROFINET

0

Supporting protocol for Data-Highway

Supporting protocol for Modbus

With PC connection

Supporting protocol for SERCOS

Max. output at linear load at rated output voltage

0.55kW

Application in domestic- and commercial area permitted

Application in industrial area permitted

Max. output frequency

400Hz

Relative symmetric net frequency tolerance

10%

Supporting protocol for AS-Interface Safety at Work

Max. output at quadratic load at rated output voltage

0.75kW

Max. output voltage

240V

Supporting protocol for BACnet

Relative symmetric net voltage tolerance

10%

Supporting protocol for EtherNet/IP

Supporting protocol for PROFINET IO

Supporting protocol for PROFINET CBA

Degree of protection (NEMA)

Other

Supporting protocol for DeviceNet Safety

Supporting protocol for PROFIsafe

Supporting protocol for Foundation Fieldbus

Supporting protocol for SafetyBUS p

Nominal output current I2N

3.7A

Related products

VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user.