Aleta.hr

Details

  • Low-voltage industrial components
  • Frequency converter =< 1 kV
  • 1 KOM
  • EATON

Technical specifications

Depth200.9mm
Height327mm
Width153mm
Number of HW-interfaces RS-4220
Number of analogue inputs2
Number of digital inputs8
Supporting protocol for TCP/IPYes
Number of HW-interfaces parallel0
Number of HW-interfaces USB0
Number of analogue outputs2
Number of HW-interfaces other1
Supporting protocol for ModbusYes
Number of HW-interfaces RS-2320
Number of HW-interfaces industrial Ethernet1
Supporting protocol for KNXNo
Supporting protocol for PROFIBUSYes
Supporting protocol for INTERBUSNo
Power consumption63W
Supporting protocol for DeviceNetYes
Supporting protocol for Data-HighwayNo
Supporting protocol for LONNo
Number of HW-interfaces RS-4851
With control elementYes
Number of digital outputs1
Supporting protocol for CANYes
Number of HW-interfaces serial TTY0
With optical interfaceNo
Supporting protocol for ASINo
Supporting protocol for other bus systemsYes
Supporting protocol for SUCONETNo
Mains voltage208 - 240V
Max. output at linear load at rated output voltage0.55kW
Mains frequency50/60 Hz
Max. output frequency400Hz
Relative symmetric net voltage tolerance10%
Application in domestic- and commercial area permittedYes
Integrated breaking resistanceYes
Type of converterU converter
Supporting protocol for INTERBUS-SafetyNo
Number of phases input3
Application in industrial area permittedYes
Number of phases output3
Number of interfaces PROFINET0
With PC connectionYes
Supporting protocol for SERCOSNo
Degree of protection (IP)IP54
Relative symmetric net frequency tolerance10%
Max. output at quadratic load at rated output voltage0.75kW
Supporting protocol for AS-Interface Safety at WorkNo
4-quadrant operation possibleYes
Supporting protocol for Foundation FieldbusNo
Supporting protocol for EtherNet/IPYes
Supporting protocol for DeviceNet SafetyNo
Supporting protocol for SafetyBUS pNo
Supporting protocol for PROFIsafeNo
Supporting protocol for BACnetYes
Supporting protocol for PROFINET CBANo
Supporting protocol for PROFINET IOYes
Max. output voltage240V
Degree of protection (NEMA)12
Nominal output current I2N3.7A

Related products

*VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user

DG1-323D7FB-C54C

Main Product Image

Why Register?

  • View wholesale prices with discounts
  • Real-time stock availability
  • Access invoices and dispatch notes
  • Order history and frequently ordered items
  • Exclusive B2B offers

and much more...

Details

  • Low-voltage industrial components
  • Frequency converter =< 1 kV
  • 1 KOM
  • EATON

Technical specifications

Depth

200.9mm

Height

327mm

Width

153mm

Number of HW-interfaces RS-422

0

Number of analogue inputs

2

Number of digital inputs

8

Supporting protocol for TCP/IP

Number of HW-interfaces parallel

0

Number of HW-interfaces USB

0

Number of analogue outputs

2

Number of HW-interfaces other

1

Supporting protocol for Modbus

Number of HW-interfaces RS-232

0

Number of HW-interfaces industrial Ethernet

1

Supporting protocol for KNX

Supporting protocol for PROFIBUS

Supporting protocol for INTERBUS

Power consumption

63W

Supporting protocol for DeviceNet

Supporting protocol for Data-Highway

Supporting protocol for LON

Number of HW-interfaces RS-485

1

With control element

Number of digital outputs

1

Supporting protocol for CAN

Number of HW-interfaces serial TTY

0

With optical interface

Supporting protocol for ASI

Supporting protocol for other bus systems

Supporting protocol for SUCONET

Mains voltage

208 .. 240V

Max. output at linear load at rated output voltage

0.55kW

Mains frequency

50/60 Hz

Max. output frequency

400Hz

Relative symmetric net voltage tolerance

10%

Application in domestic- and commercial area permitted

Integrated breaking resistance

Type of converter

U converter

Supporting protocol for INTERBUS-Safety

Number of phases input

3

Application in industrial area permitted

Number of phases output

3

Number of interfaces PROFINET

0

With PC connection

Supporting protocol for SERCOS

Degree of protection (IP)

IP54

Relative symmetric net frequency tolerance

10%

Max. output at quadratic load at rated output voltage

0.75kW

Supporting protocol for AS-Interface Safety at Work

4-quadrant operation possible

Supporting protocol for Foundation Fieldbus

Supporting protocol for EtherNet/IP

Supporting protocol for DeviceNet Safety

Supporting protocol for SafetyBUS p

Supporting protocol for PROFIsafe

Supporting protocol for BACnet

Supporting protocol for PROFINET CBA

Supporting protocol for PROFINET IO

Max. output voltage

240V

Degree of protection (NEMA)

12

Nominal output current I2N

3.7A

Related products