Aleta.hr

Details

  • Low-voltage industrial components
  • Frequency converter =< 1 kV
  • 1 KOM
  • EATON

Technical specifications

Number of digital outputs1
Number of digital inputs8
Number of analogue inputs2
Power consumption89W
Number of HW-interfaces industrial Ethernet1
Number of HW-interfaces RS-4220
Depth200.9mm
Supporting protocol for TCP/IPYes
With control elementYes
Number of HW-interfaces parallel0
Height327mm
Number of HW-interfaces RS-2320
Supporting protocol for LONNo
Width153mm
Supporting protocol for ASINo
Supporting protocol for PROFIBUSYes
Number of HW-interfaces serial TTY0
With optical interfaceNo
Number of HW-interfaces RS-4851
Number of analogue outputs2
Number of HW-interfaces other1
Number of HW-interfaces USB0
Supporting protocol for CANYes
Supporting protocol for INTERBUSNo
Supporting protocol for DeviceNetYes
Supporting protocol for INTERBUS-SafetyNo
Supporting protocol for KNXNo
Number of interfaces PROFINET0
Application in domestic- and commercial area permittedYes
Supporting protocol for ModbusYes
Supporting protocol for SUCONETNo
Max. output frequency400Hz
With PC connectionYes
Supporting protocol for Data-HighwayNo
Supporting protocol for SERCOSNo
Integrated breaking resistanceYes
4-quadrant operation possibleYes
Supporting protocol for other bus systemsYes
Application in industrial area permittedYes
Type of converterU converter
Mains frequency50/60 Hz
Relative symmetric net voltage tolerance10%
Max. output at quadratic load at rated output voltage1.5kW
Supporting protocol for DeviceNet SafetyNo
Relative symmetric net frequency tolerance10%
Supporting protocol for Foundation FieldbusNo
Supporting protocol for BACnetYes
Supporting protocol for EtherNet/IPYes
Supporting protocol for SafetyBUS pNo
Max. output voltage240V
Supporting protocol for AS-Interface Safety at WorkNo
Supporting protocol for PROFINET CBANo
Supporting protocol for PROFINET IOYes
Supporting protocol for PROFIsafeNo
Degree of protection (NEMA)1
Degree of protection (IP)IP21
Mains voltage208 - 240V
Number of phases output3
Number of phases input3
Max. output at linear load at rated output voltage1.1kW
Nominal output current I2N6.6A

Related products

*VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user

DG1-326D6FB-C21C

Main Product Image

Why Register?

  • View wholesale prices with discounts
  • Real-time stock availability
  • Access invoices and dispatch notes
  • Order history and frequently ordered items
  • Exclusive B2B offers

and much more...

Details

  • Low-voltage industrial components
  • Frequency converter =< 1 kV
  • 1 KOM
  • EATON

Technical specifications

Number of digital outputs

1

Number of digital inputs

8

Number of analogue inputs

2

Power consumption

89W

Number of HW-interfaces industrial Ethernet

1

Number of HW-interfaces RS-422

0

Depth

200.9mm

Supporting protocol for TCP/IP

With control element

Number of HW-interfaces parallel

0

Height

327mm

Number of HW-interfaces RS-232

0

Supporting protocol for LON

Width

153mm

Supporting protocol for ASI

Supporting protocol for PROFIBUS

Number of HW-interfaces serial TTY

0

With optical interface

Number of HW-interfaces RS-485

1

Number of analogue outputs

2

Number of HW-interfaces other

1

Number of HW-interfaces USB

0

Supporting protocol for CAN

Supporting protocol for INTERBUS

Supporting protocol for DeviceNet

Supporting protocol for INTERBUS-Safety

Supporting protocol for KNX

Number of interfaces PROFINET

0

Application in domestic- and commercial area permitted

Supporting protocol for Modbus

Supporting protocol for SUCONET

Max. output frequency

400Hz

With PC connection

Supporting protocol for Data-Highway

Supporting protocol for SERCOS

Integrated breaking resistance

4-quadrant operation possible

Supporting protocol for other bus systems

Application in industrial area permitted

Type of converter

U converter

Mains frequency

50/60 Hz

Relative symmetric net voltage tolerance

10%

Max. output at quadratic load at rated output voltage

1.5kW

Supporting protocol for DeviceNet Safety

Relative symmetric net frequency tolerance

10%

Supporting protocol for Foundation Fieldbus

Supporting protocol for BACnet

Supporting protocol for EtherNet/IP

Supporting protocol for SafetyBUS p

Max. output voltage

240V

Supporting protocol for AS-Interface Safety at Work

Supporting protocol for PROFINET CBA

Supporting protocol for PROFINET IO

Supporting protocol for PROFIsafe

Degree of protection (NEMA)

1

Degree of protection (IP)

IP21

Mains voltage

208 .. 240V

Number of phases output

3

Number of phases input

3

Max. output at linear load at rated output voltage

1.1kW

Nominal output current I2N

6.6A