Aleta.hr

Details

  • Low-voltage industrial components
  • Frequency converter =< 1 kV
  • 1 KOM
  • EATON

Technical specifications

Power consumption89W
Depth200.9mm
Height327mm
Width153mm
Number of analogue outputs2
With control elementYes
Number of digital outputs1
Number of analogue inputs2
Number of digital inputs8
Number of HW-interfaces RS-4851
Supporting protocol for LONNo
Number of HW-interfaces RS-4220
Supporting protocol for KNXNo
With optical interfaceNo
Supporting protocol for CANYes
Supporting protocol for ModbusYes
Number of HW-interfaces RS-2320
Supporting protocol for DeviceNetYes
Number of HW-interfaces parallel0
Supporting protocol for ASINo
Supporting protocol for TCP/IPYes
Number of HW-interfaces industrial Ethernet1
Supporting protocol for PROFIBUSYes
Number of HW-interfaces USB0
Supporting protocol for INTERBUSNo
Number of HW-interfaces other1
Number of HW-interfaces serial TTY0
Supporting protocol for INTERBUS-SafetyNo
Supporting protocol for other bus systemsYes
With PC connectionYes
Supporting protocol for SUCONETNo
Supporting protocol for SERCOSNo
Degree of protection (IP)IP54
Supporting protocol for Data-HighwayNo
Supporting protocol for DeviceNet SafetyNo
Number of interfaces PROFINET0
Application in domestic- and commercial area permittedYes
Integrated breaking resistanceYes
4-quadrant operation possibleYes
Max. output frequency400Hz
Relative symmetric net frequency tolerance10%
Number of phases output3
Relative symmetric net voltage tolerance10%
Max. output at quadratic load at rated output voltage1.5kW
Supporting protocol for AS-Interface Safety at WorkNo
Max. output at linear load at rated output voltage1.1kW
Mains voltage208 - 240V
Number of phases input3
Supporting protocol for EtherNet/IPYes
Application in industrial area permittedYes
Mains frequency50/60 Hz
Max. output voltage240V
Supporting protocol for PROFIsafeNo
Supporting protocol for PROFINET IOYes
Supporting protocol for SafetyBUS pNo
Supporting protocol for PROFINET CBANo
Nominal output current I2N6.6A
Supporting protocol for Foundation FieldbusNo
Type of converterU converter
Degree of protection (NEMA)12
Supporting protocol for BACnetYes

Related products

*VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user

DG1-326D6FB-C54C

Main Product Image

Why Register?

  • View wholesale prices with discounts
  • Real-time stock availability
  • Access invoices and dispatch notes
  • Order history and frequently ordered items
  • Exclusive B2B offers

and much more...

Details

  • Low-voltage industrial components
  • Frequency converter =< 1 kV
  • 1 KOM
  • EATON

Technical specifications

Power consumption

89W

Depth

200.9mm

Height

327mm

Width

153mm

Number of analogue outputs

2

With control element

Number of digital outputs

1

Number of analogue inputs

2

Number of digital inputs

8

Number of HW-interfaces RS-485

1

Supporting protocol for LON

Number of HW-interfaces RS-422

0

Supporting protocol for KNX

With optical interface

Supporting protocol for CAN

Supporting protocol for Modbus

Number of HW-interfaces RS-232

0

Supporting protocol for DeviceNet

Number of HW-interfaces parallel

0

Supporting protocol for ASI

Supporting protocol for TCP/IP

Number of HW-interfaces industrial Ethernet

1

Supporting protocol for PROFIBUS

Number of HW-interfaces USB

0

Supporting protocol for INTERBUS

Number of HW-interfaces other

1

Number of HW-interfaces serial TTY

0

Supporting protocol for INTERBUS-Safety

Supporting protocol for other bus systems

With PC connection

Supporting protocol for SUCONET

Supporting protocol for SERCOS

Degree of protection (IP)

IP54

Supporting protocol for Data-Highway

Supporting protocol for DeviceNet Safety

Number of interfaces PROFINET

0

Application in domestic- and commercial area permitted

Integrated breaking resistance

4-quadrant operation possible

Max. output frequency

400Hz

Relative symmetric net frequency tolerance

10%

Number of phases output

3

Relative symmetric net voltage tolerance

10%

Max. output at quadratic load at rated output voltage

1.5kW

Supporting protocol for AS-Interface Safety at Work

Max. output at linear load at rated output voltage

1.1kW

Mains voltage

208 .. 240V

Number of phases input

3

Supporting protocol for EtherNet/IP

Application in industrial area permitted

Mains frequency

50/60 Hz

Max. output voltage

240V

Supporting protocol for PROFIsafe

Supporting protocol for PROFINET IO

Supporting protocol for SafetyBUS p

Supporting protocol for PROFINET CBA

Nominal output current I2N

6.6A

Supporting protocol for Foundation Fieldbus

Type of converter

U converter

Degree of protection (NEMA)

12

Supporting protocol for BACnet