Aleta.hr

Details

  • Low-voltage industrial components
  • Frequency converter =< 1 kV
  • 1 KOM
  • EATON

Technical specifications

With control elementYes
Depth244.7mm
Number of HW-interfaces RS-2320
Number of HW-interfaces serial TTY0
Number of HW-interfaces RS-4220
Number of analogue outputs2
Number of digital inputs8
Number of analogue inputs2
Supporting protocol for LONNo
Height419mm
Number of digital outputs1
Number of HW-interfaces RS-4851
Number of HW-interfaces industrial Ethernet1
Number of HW-interfaces USB0
Width167.8mm
Power consumption293W
Supporting protocol for PROFIBUSYes
Supporting protocol for ASINo
Supporting protocol for TCP/IPYes
Number of HW-interfaces parallel0
With optical interfaceNo
Number of HW-interfaces other1
Supporting protocol for INTERBUSNo
Supporting protocol for CANYes
Supporting protocol for ModbusYes
Supporting protocol for Data-HighwayNo
Supporting protocol for DeviceNetYes
Supporting protocol for SUCONETNo
Degree of protection (IP)IP21
With PC connectionYes
Supporting protocol for SERCOSNo
Number of phases output3
4-quadrant operation possibleYes
Supporting protocol for KNXNo
Supporting protocol for INTERBUS-SafetyNo
Mains frequency50/60 Hz
Mains voltage380 - 500V
Number of interfaces PROFINET0
Type of converterU converter
Supporting protocol for other bus systemsYes
Number of phases input3
Integrated breaking resistanceYes
Application in industrial area permittedYes
Application in domestic- and commercial area permittedYes
Max. output frequency400Hz
Max. output at linear load at rated output voltage7.5kW
Max. output at quadratic load at rated output voltage11kW
Supporting protocol for EtherNet/IPYes
Supporting protocol for AS-Interface Safety at WorkNo
Relative symmetric net frequency tolerance10%
Supporting protocol for PROFINET CBANo
Supporting protocol for DeviceNet SafetyNo
Supporting protocol for SafetyBUS pNo
Supporting protocol for Foundation FieldbusNo
Nominal output current I2N16A
Max. output voltage500V
Supporting protocol for PROFINET IOYes
Degree of protection (NEMA)1
Supporting protocol for PROFIsafeNo
Supporting protocol for BACnetYes
Relative symmetric net voltage tolerance10%

Related products

*VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user

DG1-34016FB-C21C

Main Product Image

Why Register?

  • View wholesale prices with discounts
  • Real-time stock availability
  • Access invoices and dispatch notes
  • Order history and frequently ordered items
  • Exclusive B2B offers

and much more...

Details

  • Low-voltage industrial components
  • Frequency converter =< 1 kV
  • 1 KOM
  • EATON

Technical specifications

With control element

Depth

244.7mm

Number of HW-interfaces RS-232

0

Number of HW-interfaces serial TTY

0

Number of HW-interfaces RS-422

0

Number of analogue outputs

2

Number of digital inputs

8

Number of analogue inputs

2

Supporting protocol for LON

Height

419mm

Number of digital outputs

1

Number of HW-interfaces RS-485

1

Number of HW-interfaces industrial Ethernet

1

Number of HW-interfaces USB

0

Width

167.8mm

Power consumption

293W

Supporting protocol for PROFIBUS

Supporting protocol for ASI

Supporting protocol for TCP/IP

Number of HW-interfaces parallel

0

With optical interface

Number of HW-interfaces other

1

Supporting protocol for INTERBUS

Supporting protocol for CAN

Supporting protocol for Modbus

Supporting protocol for Data-Highway

Supporting protocol for DeviceNet

Supporting protocol for SUCONET

Degree of protection (IP)

IP21

With PC connection

Supporting protocol for SERCOS

Number of phases output

3

4-quadrant operation possible

Supporting protocol for KNX

Supporting protocol for INTERBUS-Safety

Mains frequency

50/60 Hz

Mains voltage

380 .. 500V

Number of interfaces PROFINET

0

Type of converter

U converter

Supporting protocol for other bus systems

Number of phases input

3

Integrated breaking resistance

Application in industrial area permitted

Application in domestic- and commercial area permitted

Max. output frequency

400Hz

Max. output at linear load at rated output voltage

7.5kW

Max. output at quadratic load at rated output voltage

11kW

Supporting protocol for EtherNet/IP

Supporting protocol for AS-Interface Safety at Work

Relative symmetric net frequency tolerance

10%

Supporting protocol for PROFINET CBA

Supporting protocol for DeviceNet Safety

Supporting protocol for SafetyBUS p

Supporting protocol for Foundation Fieldbus

Nominal output current I2N

16A

Max. output voltage

500V

Supporting protocol for PROFINET IO

Degree of protection (NEMA)

1

Supporting protocol for PROFIsafe

Supporting protocol for BACnet

Relative symmetric net voltage tolerance

10%

Related products

VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user.