Aleta.hr

Details

  • Low-voltage industrial components
  • Frequency converter =< 1 kV
  • 1 KOM
  • EATON

Technical specifications

Depth265.1mm
Width204.6mm
With control elementYes
Power consumption471W
Height558mm
Number of HW-interfaces RS-4220
Number of digital inputs8
Supporting protocol for ModbusYes
Supporting protocol for LONNo
Supporting protocol for INTERBUSNo
Number of HW-interfaces RS-2320
Supporting protocol for KNXNo
With optical interfaceNo
Number of HW-interfaces industrial Ethernet1
Supporting protocol for TCP/IPYes
Number of HW-interfaces serial TTY0
Number of HW-interfaces USB0
Number of HW-interfaces other1
Number of HW-interfaces RS-4851
Supporting protocol for CANYes
Number of analogue outputs2
Supporting protocol for ASINo
Supporting protocol for PROFIBUSYes
Number of analogue inputs2
Number of HW-interfaces parallel0
Number of digital outputs1
Supporting protocol for Data-HighwayNo
Supporting protocol for DeviceNetYes
Supporting protocol for other bus systemsYes
Supporting protocol for SUCONETNo
Supporting protocol for SERCOSNo
With PC connectionYes
Type of converterU converter
Max. output at linear load at rated output voltage15kW
Application in domestic- and commercial area permittedYes
Max. output frequency400Hz
Supporting protocol for INTERBUS-SafetyNo
Number of phases output3
Number of phases input3
Relative symmetric net frequency tolerance10%
Mains voltage380 - 500V
4-quadrant operation possibleYes
Supporting protocol for DeviceNet SafetyNo
Degree of protection (IP)IP54
Integrated breaking resistanceYes
Number of interfaces PROFINET0
Max. output at quadratic load at rated output voltage18.5kW
Application in industrial area permittedYes
Supporting protocol for AS-Interface Safety at WorkNo
Relative symmetric net voltage tolerance10%
Mains frequency50/60 Hz
Supporting protocol for PROFINET IOYes
Supporting protocol for PROFINET CBANo
Supporting protocol for Foundation FieldbusNo
Supporting protocol for EtherNet/IPYes
Supporting protocol for SafetyBUS pNo
Supporting protocol for PROFIsafeNo
Nominal output current I2N31A
Max. output voltage500V
Degree of protection (NEMA)12
Supporting protocol for BACnetYes

Related products

*VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user

DG1-34031FB-C54C

Main Product Image

Why Register?

  • View wholesale prices with discounts
  • Real-time stock availability
  • Access invoices and dispatch notes
  • Order history and frequently ordered items
  • Exclusive B2B offers

and much more...

Details

  • Low-voltage industrial components
  • Frequency converter =< 1 kV
  • 1 KOM
  • EATON

Technical specifications

Depth

265.1mm

Width

204.6mm

With control element

Power consumption

471W

Height

558mm

Number of HW-interfaces RS-422

0

Number of digital inputs

8

Supporting protocol for Modbus

Supporting protocol for LON

Supporting protocol for INTERBUS

Number of HW-interfaces RS-232

0

Supporting protocol for KNX

With optical interface

Number of HW-interfaces industrial Ethernet

1

Supporting protocol for TCP/IP

Number of HW-interfaces serial TTY

0

Number of HW-interfaces USB

0

Number of HW-interfaces other

1

Number of HW-interfaces RS-485

1

Supporting protocol for CAN

Number of analogue outputs

2

Supporting protocol for ASI

Supporting protocol for PROFIBUS

Number of analogue inputs

2

Number of HW-interfaces parallel

0

Number of digital outputs

1

Supporting protocol for Data-Highway

Supporting protocol for DeviceNet

Supporting protocol for other bus systems

Supporting protocol for SUCONET

Supporting protocol for SERCOS

With PC connection

Type of converter

U converter

Max. output at linear load at rated output voltage

15kW

Application in domestic- and commercial area permitted

Max. output frequency

400Hz

Supporting protocol for INTERBUS-Safety

Number of phases output

3

Number of phases input

3

Relative symmetric net frequency tolerance

10%

Mains voltage

380 .. 500V

4-quadrant operation possible

Supporting protocol for DeviceNet Safety

Degree of protection (IP)

IP54

Integrated breaking resistance

Number of interfaces PROFINET

0

Max. output at quadratic load at rated output voltage

18.5kW

Application in industrial area permitted

Supporting protocol for AS-Interface Safety at Work

Relative symmetric net voltage tolerance

10%

Mains frequency

50/60 Hz

Supporting protocol for PROFINET IO

Supporting protocol for PROFINET CBA

Supporting protocol for Foundation Fieldbus

Supporting protocol for EtherNet/IP

Supporting protocol for SafetyBUS p

Supporting protocol for PROFIsafe

Nominal output current I2N

31A

Max. output voltage

500V

Degree of protection (NEMA)

12

Supporting protocol for BACnet

Related products

VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user.