Aleta.hr

Details

  • Low-voltage industrial components
  • Frequency converter =< 1 kV
  • 1 KOM
  • EATON

Technical specifications

Number of HW-interfaces other1
Depth294mm
Number of HW-interfaces RS-4220
Supporting protocol for LONNo
Number of analogue outputs2
Number of digital outputs1
Number of HW-interfaces USB0
Width237.7mm
Number of HW-interfaces RS-4851
Height630mm
Number of HW-interfaces serial TTY0
Number of analogue inputs2
With control elementYes
Number of HW-interfaces RS-2320
Number of HW-interfaces industrial Ethernet1
Number of HW-interfaces parallel0
Supporting protocol for PROFIBUSYes
Supporting protocol for ASINo
Power consumption758W
Supporting protocol for CANYes
Supporting protocol for TCP/IPYes
With optical interfaceNo
Supporting protocol for INTERBUSNo
Number of digital inputs8
Type of converterU converter
Supporting protocol for KNXNo
Supporting protocol for DeviceNetYes
Supporting protocol for SERCOSNo
Mains frequency50/60 Hz
Max. output frequency400Hz
Supporting protocol for SUCONETNo
Degree of protection (IP)IP54
Application in industrial area permittedYes
Supporting protocol for INTERBUS-SafetyNo
4-quadrant operation possibleNo
Number of phases output3
Supporting protocol for Data-HighwayNo
Number of interfaces PROFINET0
Supporting protocol for ModbusYes
Application in domestic- and commercial area permittedYes
Integrated breaking resistanceNo
Supporting protocol for other bus systemsYes
Number of phases input3
With PC connectionYes
Max. output at quadratic load at rated output voltage37kW
Relative symmetric net frequency tolerance10%
Relative symmetric net voltage tolerance10%
Max. output at linear load at rated output voltage30kW
Mains voltage380 - 500V
Supporting protocol for DeviceNet SafetyNo
Supporting protocol for PROFINET IOYes
Max. output voltage500V
Supporting protocol for EtherNet/IPYes
Supporting protocol for PROFIsafeNo
Supporting protocol for Foundation FieldbusNo
Supporting protocol for SafetyBUS pNo
Supporting protocol for AS-Interface Safety at WorkNo
Degree of protection (NEMA)12
Supporting protocol for BACnetYes
Supporting protocol for PROFINET CBANo
Nominal output current I2N61A

Related products

*VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user

DG1-34061FN-C54C

Main Product Image

Why Register?

  • View wholesale prices with discounts
  • Real-time stock availability
  • Access invoices and dispatch notes
  • Order history and frequently ordered items
  • Exclusive B2B offers

and much more...

Details

  • Low-voltage industrial components
  • Frequency converter =< 1 kV
  • 1 KOM
  • EATON

Technical specifications

Number of HW-interfaces other

1

Depth

294mm

Number of HW-interfaces RS-422

0

Supporting protocol for LON

Number of analogue outputs

2

Number of digital outputs

1

Number of HW-interfaces USB

0

Width

237.7mm

Number of HW-interfaces RS-485

1

Height

630mm

Number of HW-interfaces serial TTY

0

Number of analogue inputs

2

With control element

Number of HW-interfaces RS-232

0

Number of HW-interfaces industrial Ethernet

1

Number of HW-interfaces parallel

0

Supporting protocol for PROFIBUS

Supporting protocol for ASI

Power consumption

758W

Supporting protocol for CAN

Supporting protocol for TCP/IP

With optical interface

Supporting protocol for INTERBUS

Number of digital inputs

8

Type of converter

U converter

Supporting protocol for KNX

Supporting protocol for DeviceNet

Supporting protocol for SERCOS

Mains frequency

50/60 Hz

Max. output frequency

400Hz

Supporting protocol for SUCONET

Degree of protection (IP)

IP54

Application in industrial area permitted

Supporting protocol for INTERBUS-Safety

4-quadrant operation possible

Number of phases output

3

Supporting protocol for Data-Highway

Number of interfaces PROFINET

0

Supporting protocol for Modbus

Application in domestic- and commercial area permitted

Integrated breaking resistance

Supporting protocol for other bus systems

Number of phases input

3

With PC connection

Max. output at quadratic load at rated output voltage

37kW

Relative symmetric net frequency tolerance

10%

Relative symmetric net voltage tolerance

10%

Max. output at linear load at rated output voltage

30kW

Mains voltage

380 .. 500V

Supporting protocol for DeviceNet Safety

Supporting protocol for PROFINET IO

Max. output voltage

500V

Supporting protocol for EtherNet/IP

Supporting protocol for PROFIsafe

Supporting protocol for Foundation Fieldbus

Supporting protocol for SafetyBUS p

Supporting protocol for AS-Interface Safety at Work

Degree of protection (NEMA)

12

Supporting protocol for BACnet

Supporting protocol for PROFINET CBA

Nominal output current I2N

61A

Related products