Aleta.hr

Details

  • Low-voltage industrial components
  • Frequency converter =< 1 kV
  • 1 KOM
  • EATON

Technical specifications

Power consumption1217W
Height630mm
Width237.7mm
Depth294mm
Supporting protocol for DeviceNetYes
With optical interfaceNo
Number of HW-interfaces industrial Ethernet1
Number of HW-interfaces parallel0
Number of analogue inputs2
Supporting protocol for CANYes
Number of HW-interfaces RS-2320
Supporting protocol for KNXNo
Number of HW-interfaces other1
Number of digital inputs8
Number of HW-interfaces serial TTY0
Supporting protocol for INTERBUSNo
Supporting protocol for ASINo
Supporting protocol for SUCONETNo
Number of digital outputs1
Number of HW-interfaces RS-4851
Supporting protocol for PROFIBUSYes
Supporting protocol for LONNo
Number of HW-interfaces RS-4220
Supporting protocol for ModbusYes
Number of analogue outputs2
Supporting protocol for Data-HighwayNo
Supporting protocol for TCP/IPYes
Number of HW-interfaces USB0
With control elementYes
Supporting protocol for PROFINET CBANo
Supporting protocol for other bus systemsYes
Type of converterU converter
Supporting protocol for EtherNet/IPYes
Number of phases output3
4-quadrant operation possibleYes
Supporting protocol for AS-Interface Safety at WorkNo
Mains voltage380 - 500V
Max. output at linear load at rated output voltage45kW
Application in domestic- and commercial area permittedYes
Relative symmetric net frequency tolerance10%
Integrated breaking resistanceYes
Degree of protection (IP)IP21
Application in industrial area permittedYes
With PC connectionYes
Supporting protocol for DeviceNet SafetyNo
Number of phases input3
Number of interfaces PROFINET0
Max. output at quadratic load at rated output voltage55kW
Supporting protocol for Foundation FieldbusNo
Supporting protocol for INTERBUS-SafetyNo
Supporting protocol for SERCOSNo
Max. output frequency400Hz
Relative symmetric net voltage tolerance10%
Mains frequency50/60 Hz
Supporting protocol for SafetyBUS pNo
Nominal output current I2N87A
Degree of protection (NEMA)1
Supporting protocol for PROFINET IOYes
Supporting protocol for PROFIsafeNo
Max. output voltage500V
Supporting protocol for BACnetYes

Related products

*VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user

DG1-34087FB-C21C

Main Product Image

Why Register?

  • View wholesale prices with discounts
  • Real-time stock availability
  • Access invoices and dispatch notes
  • Order history and frequently ordered items
  • Exclusive B2B offers

and much more...

Details

  • Low-voltage industrial components
  • Frequency converter =< 1 kV
  • 1 KOM
  • EATON

Technical specifications

Power consumption

1217W

Height

630mm

Width

237.7mm

Depth

294mm

Supporting protocol for DeviceNet

With optical interface

Number of HW-interfaces industrial Ethernet

1

Number of HW-interfaces parallel

0

Number of analogue inputs

2

Supporting protocol for CAN

Number of HW-interfaces RS-232

0

Supporting protocol for KNX

Number of HW-interfaces other

1

Number of digital inputs

8

Number of HW-interfaces serial TTY

0

Supporting protocol for INTERBUS

Supporting protocol for ASI

Supporting protocol for SUCONET

Number of digital outputs

1

Number of HW-interfaces RS-485

1

Supporting protocol for PROFIBUS

Supporting protocol for LON

Number of HW-interfaces RS-422

0

Supporting protocol for Modbus

Number of analogue outputs

2

Supporting protocol for Data-Highway

Supporting protocol for TCP/IP

Number of HW-interfaces USB

0

With control element

Supporting protocol for PROFINET CBA

Supporting protocol for other bus systems

Type of converter

U converter

Supporting protocol for EtherNet/IP

Number of phases output

3

4-quadrant operation possible

Supporting protocol for AS-Interface Safety at Work

Mains voltage

380 .. 500V

Max. output at linear load at rated output voltage

45kW

Application in domestic- and commercial area permitted

Relative symmetric net frequency tolerance

10%

Integrated breaking resistance

Degree of protection (IP)

IP21

Application in industrial area permitted

With PC connection

Supporting protocol for DeviceNet Safety

Number of phases input

3

Number of interfaces PROFINET

0

Max. output at quadratic load at rated output voltage

55kW

Supporting protocol for Foundation Fieldbus

Supporting protocol for INTERBUS-Safety

Supporting protocol for SERCOS

Max. output frequency

400Hz

Relative symmetric net voltage tolerance

10%

Mains frequency

50/60 Hz

Supporting protocol for SafetyBUS p

Nominal output current I2N

87A

Degree of protection (NEMA)

1

Supporting protocol for PROFINET IO

Supporting protocol for PROFIsafe

Max. output voltage

500V

Supporting protocol for BACnet

Related products

VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user.