Aleta.hr

Details

  • Low-voltage industrial components
  • Frequency converter =< 1 kV
  • 1 KOM
  • EATON

Technical specifications

With control elementYes
Power consumption1217W
Depth294mm
Width237.7mm
Number of digital outputs1
Height630mm
Number of digital inputs8
Number of HW-interfaces industrial Ethernet1
Number of HW-interfaces RS-2320
Number of analogue outputs2
Number of HW-interfaces RS-4220
Number of analogue inputs2
Number of HW-interfaces serial TTY0
Number of HW-interfaces RS-4851
Supporting protocol for LONNo
Number of HW-interfaces other1
Number of HW-interfaces parallel0
Number of HW-interfaces USB0
Supporting protocol for TCP/IPYes
Supporting protocol for CANYes
Supporting protocol for ASINo
With PC connectionYes
With optical interfaceNo
Supporting protocol for INTERBUSNo
Supporting protocol for KNXNo
Supporting protocol for SUCONETNo
Mains voltage380 - 500V
Supporting protocol for SERCOSNo
Degree of protection (IP)IP54
Supporting protocol for other bus systemsYes
Supporting protocol for ModbusYes
Supporting protocol for DeviceNetYes
Supporting protocol for Data-HighwayNo
Supporting protocol for INTERBUS-SafetyNo
Supporting protocol for PROFIBUSYes
Mains frequency50/60 Hz
Number of phases output3
Type of converterU converter
Number of interfaces PROFINET0
4-quadrant operation possibleNo
Number of phases input3
Application in domestic- and commercial area permittedYes
Integrated breaking resistanceNo
Max. output frequency400Hz
Supporting protocol for AS-Interface Safety at WorkNo
Application in industrial area permittedYes
Supporting protocol for DeviceNet SafetyNo
Supporting protocol for PROFINET CBANo
Max. output at linear load at rated output voltage45kW
Relative symmetric net frequency tolerance10%
Max. output at quadratic load at rated output voltage55kW
Supporting protocol for Foundation FieldbusNo
Supporting protocol for PROFINET IOYes
Relative symmetric net voltage tolerance10%
Supporting protocol for EtherNet/IPYes
Nominal output current I2N87A
Supporting protocol for SafetyBUS pNo
Degree of protection (NEMA)12
Supporting protocol for PROFIsafeNo
Max. output voltage500V
Supporting protocol for BACnetYes

Related products

*VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user

DG1-34087FN-C54C

Main Product Image

Why Register?

  • View wholesale prices with discounts
  • Real-time stock availability
  • Access invoices and dispatch notes
  • Order history and frequently ordered items
  • Exclusive B2B offers

and much more...

Details

  • Low-voltage industrial components
  • Frequency converter =< 1 kV
  • 1 KOM
  • EATON

Technical specifications

With control element

Power consumption

1217W

Depth

294mm

Width

237.7mm

Number of digital outputs

1

Height

630mm

Number of digital inputs

8

Number of HW-interfaces industrial Ethernet

1

Number of HW-interfaces RS-232

0

Number of analogue outputs

2

Number of HW-interfaces RS-422

0

Number of analogue inputs

2

Number of HW-interfaces serial TTY

0

Number of HW-interfaces RS-485

1

Supporting protocol for LON

Number of HW-interfaces other

1

Number of HW-interfaces parallel

0

Number of HW-interfaces USB

0

Supporting protocol for TCP/IP

Supporting protocol for CAN

Supporting protocol for ASI

With PC connection

With optical interface

Supporting protocol for INTERBUS

Supporting protocol for KNX

Supporting protocol for SUCONET

Mains voltage

380 .. 500V

Supporting protocol for SERCOS

Degree of protection (IP)

IP54

Supporting protocol for other bus systems

Supporting protocol for Modbus

Supporting protocol for DeviceNet

Supporting protocol for Data-Highway

Supporting protocol for INTERBUS-Safety

Supporting protocol for PROFIBUS

Mains frequency

50/60 Hz

Number of phases output

3

Type of converter

U converter

Number of interfaces PROFINET

0

4-quadrant operation possible

Number of phases input

3

Application in domestic- and commercial area permitted

Integrated breaking resistance

Max. output frequency

400Hz

Supporting protocol for AS-Interface Safety at Work

Application in industrial area permitted

Supporting protocol for DeviceNet Safety

Supporting protocol for PROFINET CBA

Max. output at linear load at rated output voltage

45kW

Relative symmetric net frequency tolerance

10%

Max. output at quadratic load at rated output voltage

55kW

Supporting protocol for Foundation Fieldbus

Supporting protocol for PROFINET IO

Relative symmetric net voltage tolerance

10%

Supporting protocol for EtherNet/IP

Nominal output current I2N

87A

Supporting protocol for SafetyBUS p

Degree of protection (NEMA)

12

Supporting protocol for PROFIsafe

Max. output voltage

500V

Supporting protocol for BACnet

Related products

VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user.