Aleta.hr

Details

  • Low-voltage industrial components
  • Frequency converter =< 1 kV
  • 1 KOM
  • EATON

Technical specifications

Number of HW-interfaces RS-4851
Number of analogue inputs2
Number of HW-interfaces RS-2320
Number of digital outputs1
With control elementYes
Number of HW-interfaces RS-4220
Number of HW-interfaces parallel0
Number of digital inputs8
Depth340.7mm
Number of HW-interfaces serial TTY0
Supporting protocol for LONNo
Height888.5mm
Power consumption1289W
Width288mm
Number of HW-interfaces industrial Ethernet1
Number of analogue outputs2
Number of HW-interfaces USB0
Supporting protocol for TCP/IPYes
Number of HW-interfaces other1
With optical interfaceNo
Supporting protocol for ASINo
Supporting protocol for INTERBUSNo
Supporting protocol for INTERBUS-SafetyNo
Number of phases output3
Supporting protocol for CANYes
Application in industrial area permittedYes
Supporting protocol for Data-HighwayNo
Supporting protocol for ModbusYes
Max. output frequency400Hz
Mains frequency50/60 Hz
4-quadrant operation possibleNo
Application in domestic- and commercial area permittedYes
Supporting protocol for PROFIBUSYes
Supporting protocol for SERCOSNo
Supporting protocol for SUCONETNo
Number of phases input3
Mains voltage380 - 500V
Type of converterU converter
Supporting protocol for other bus systemsYes
With PC connectionYes
Integrated breaking resistanceNo
Supporting protocol for KNXNo
Max. output at linear load at rated output voltage55kW
Degree of protection (IP)IP54
Supporting protocol for DeviceNetYes
Number of interfaces PROFINET0
Relative symmetric net voltage tolerance10%
Relative symmetric net frequency tolerance10%
Supporting protocol for AS-Interface Safety at WorkNo
Max. output at quadratic load at rated output voltage75kW
Supporting protocol for DeviceNet SafetyNo
Supporting protocol for PROFINET CBANo
Supporting protocol for Foundation FieldbusNo
Supporting protocol for EtherNet/IPYes
Max. output voltage500V
Supporting protocol for SafetyBUS pNo
Supporting protocol for PROFINET IOYes
Nominal output current I2N105A
Supporting protocol for BACnetYes
Supporting protocol for PROFIsafeNo
Degree of protection (NEMA)12

Related products

*VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user

DG1-34105FN-C54C

Main Product Image

Why Register?

  • View wholesale prices with discounts
  • Real-time stock availability
  • Access invoices and dispatch notes
  • Order history and frequently ordered items
  • Exclusive B2B offers

and much more...

Details

  • Low-voltage industrial components
  • Frequency converter =< 1 kV
  • 1 KOM
  • EATON

Technical specifications

Number of HW-interfaces RS-485

1

Number of analogue inputs

2

Number of HW-interfaces RS-232

0

Number of digital outputs

1

With control element

Number of HW-interfaces RS-422

0

Number of HW-interfaces parallel

0

Number of digital inputs

8

Depth

340.7mm

Number of HW-interfaces serial TTY

0

Supporting protocol for LON

Height

888.5mm

Power consumption

1289W

Width

288mm

Number of HW-interfaces industrial Ethernet

1

Number of analogue outputs

2

Number of HW-interfaces USB

0

Supporting protocol for TCP/IP

Number of HW-interfaces other

1

With optical interface

Supporting protocol for ASI

Supporting protocol for INTERBUS

Supporting protocol for INTERBUS-Safety

Number of phases output

3

Supporting protocol for CAN

Application in industrial area permitted

Supporting protocol for Data-Highway

Supporting protocol for Modbus

Max. output frequency

400Hz

Mains frequency

50/60 Hz

4-quadrant operation possible

Application in domestic- and commercial area permitted

Supporting protocol for PROFIBUS

Supporting protocol for SERCOS

Supporting protocol for SUCONET

Number of phases input

3

Mains voltage

380 .. 500V

Type of converter

U converter

Supporting protocol for other bus systems

With PC connection

Integrated breaking resistance

Supporting protocol for KNX

Max. output at linear load at rated output voltage

55kW

Degree of protection (IP)

IP54

Supporting protocol for DeviceNet

Number of interfaces PROFINET

0

Relative symmetric net voltage tolerance

10%

Relative symmetric net frequency tolerance

10%

Supporting protocol for AS-Interface Safety at Work

Max. output at quadratic load at rated output voltage

75kW

Supporting protocol for DeviceNet Safety

Supporting protocol for PROFINET CBA

Supporting protocol for Foundation Fieldbus

Supporting protocol for EtherNet/IP

Max. output voltage

500V

Supporting protocol for SafetyBUS p

Supporting protocol for PROFINET IO

Nominal output current I2N

105A

Supporting protocol for BACnet

Supporting protocol for PROFIsafe

Degree of protection (NEMA)

12

Related products

VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user.