  • Low-voltage industrial components
  • Frequency converter =< 1 kV
  • 1 KOM
  • EATON

Technical specifications

Number of HW-interfaces industrial Ethernet1
Power consumption1594W
Number of digital outputs1
Depth340.7mm
Number of analogue outputs2
Supporting protocol for LONNo
Width288mm
Number of digital inputs8
Number of analogue inputs2
With control elementYes
Height888.5mm
Number of HW-interfaces RS-2320
Number of HW-interfaces parallel0
Number of HW-interfaces USB0
4-quadrant operation possibleNo
Supporting protocol for Data-HighwayNo
Supporting protocol for TCP/IPYes
Number of HW-interfaces other1
Supporting protocol for SUCONETNo
Mains voltage380 - 500V
Number of HW-interfaces RS-4851
Supporting protocol for CANYes
Supporting protocol for ASINo
Supporting protocol for DeviceNetYes
Supporting protocol for SERCOSNo
Supporting protocol for KNXNo
With optical interfaceNo
Supporting protocol for other bus systemsYes
Mains frequency50/60 Hz
Degree of protection (IP)IP54
Supporting protocol for ModbusYes
Supporting protocol for INTERBUSNo
Number of HW-interfaces serial TTY0
Supporting protocol for PROFIBUSYes
Supporting protocol for INTERBUS-SafetyNo
Number of HW-interfaces RS-4220
With PC connectionYes
Number of interfaces PROFINET0
Max. output at quadratic load at rated output voltage90kW
Number of phases output3
Relative symmetric net voltage tolerance10%
Integrated breaking resistanceNo
Supporting protocol for DeviceNet SafetyNo
Number of phases input3
Relative symmetric net frequency tolerance10%
Type of converterU converter
Max. output at linear load at rated output voltage75kW
Supporting protocol for AS-Interface Safety at WorkNo
Max. output frequency400Hz
Application in domestic- and commercial area permittedYes
Supporting protocol for EtherNet/IPYes
Application in industrial area permittedYes
Supporting protocol for Foundation FieldbusNo
Supporting protocol for SafetyBUS pNo
Supporting protocol for PROFINET CBANo
Supporting protocol for BACnetYes
Nominal output current I2N140A
Max. output voltage500V
Supporting protocol for PROFINET IOYes
Degree of protection (NEMA)12
Supporting protocol for PROFIsafeNo

Related products

*VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user

DG1-34140FN-C54C

Main Product Image

Why Register?

  • View wholesale prices with discounts
  • Real-time stock availability
  • Access invoices and dispatch notes
  • Order history and frequently ordered items
  • Exclusive B2B offers

and much more...

Details

  • Low-voltage industrial components
  • Frequency converter =< 1 kV
  • 1 KOM
  • EATON

Technical specifications

Number of HW-interfaces industrial Ethernet

1

Power consumption

1594W

Number of digital outputs

1

Depth

340.7mm

Number of analogue outputs

2

Supporting protocol for LON

Width

288mm

Number of digital inputs

8

Number of analogue inputs

2

With control element

Height

888.5mm

Number of HW-interfaces RS-232

0

Number of HW-interfaces parallel

0

Number of HW-interfaces USB

0

4-quadrant operation possible

Supporting protocol for Data-Highway

Supporting protocol for TCP/IP

Number of HW-interfaces other

1

Supporting protocol for SUCONET

Mains voltage

380 .. 500V

Number of HW-interfaces RS-485

1

Supporting protocol for CAN

Supporting protocol for ASI

Supporting protocol for DeviceNet

Supporting protocol for SERCOS

Supporting protocol for KNX

With optical interface

Supporting protocol for other bus systems

Mains frequency

50/60 Hz

Degree of protection (IP)

IP54

Supporting protocol for Modbus

Supporting protocol for INTERBUS

Number of HW-interfaces serial TTY

0

Supporting protocol for PROFIBUS

Supporting protocol for INTERBUS-Safety

Number of HW-interfaces RS-422

0

With PC connection

Number of interfaces PROFINET

0

Max. output at quadratic load at rated output voltage

90kW

Number of phases output

3

Relative symmetric net voltage tolerance

10%

Integrated breaking resistance

Supporting protocol for DeviceNet Safety

Number of phases input

3

Relative symmetric net frequency tolerance

10%

Type of converter

U converter

Max. output at linear load at rated output voltage

75kW

Supporting protocol for AS-Interface Safety at Work

Max. output frequency

400Hz

Application in domestic- and commercial area permitted

Supporting protocol for EtherNet/IP

Application in industrial area permitted

Supporting protocol for Foundation Fieldbus

Supporting protocol for SafetyBUS p

Supporting protocol for PROFINET CBA

Supporting protocol for BACnet

Nominal output current I2N

140A

Max. output voltage

500V

Supporting protocol for PROFINET IO

Degree of protection (NEMA)

12

Supporting protocol for PROFIsafe