Aleta.hr

Details

  • Low-voltage industrial components
  • Frequency converter =< 1 kV
  • 1 KOM
  • EATON

Technical specifications

Number of digital outputs1
Depth340.7mm
Height888.5mm
Number of digital inputs8
Power consumption2024W
Width288mm
Number of analogue inputs2
With control elementYes
Supporting protocol for LONNo
Number of HW-interfaces RS-4220
Number of HW-interfaces RS-4851
Number of HW-interfaces serial TTY0
Number of HW-interfaces USB0
Number of HW-interfaces industrial Ethernet1
Number of HW-interfaces RS-2320
Number of analogue outputs2
Supporting protocol for PROFIBUSYes
Supporting protocol for INTERBUSNo
Supporting protocol for Data-HighwayNo
Supporting protocol for TCP/IPYes
Supporting protocol for ASINo
Number of HW-interfaces other1
Number of HW-interfaces parallel0
Degree of protection (IP)IP21
Supporting protocol for ModbusYes
With optical interfaceNo
Supporting protocol for other bus systemsYes
Supporting protocol for DeviceNetYes
Supporting protocol for KNXNo
Supporting protocol for CANYes
Supporting protocol for SUCONETNo
Supporting protocol for INTERBUS-SafetyNo
With PC connectionYes
Supporting protocol for SERCOSNo
Mains voltage380 - 500V
Number of phases output3
4-quadrant operation possibleYes
Number of phases input3
Mains frequency50/60 Hz
Type of converterU converter
Number of interfaces PROFINET0
Relative symmetric net voltage tolerance10%
Max. output frequency400Hz
Application in industrial area permittedYes
Max. output at quadratic load at rated output voltage110kW
Supporting protocol for DeviceNet SafetyNo
Supporting protocol for PROFINET CBANo
Application in domestic- and commercial area permittedYes
Supporting protocol for EtherNet/IPYes
Relative symmetric net frequency tolerance10%
Max. output at linear load at rated output voltage90kW
Supporting protocol for PROFIsafeNo
Integrated breaking resistanceYes
Supporting protocol for Foundation FieldbusNo
Supporting protocol for AS-Interface Safety at WorkNo
Supporting protocol for PROFINET IOYes
Degree of protection (NEMA)1
Supporting protocol for SafetyBUS pNo
Supporting protocol for BACnetYes
Nominal output current I2N170A
Max. output voltage500V

Related products

*VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user

DG1-34170FB-C21C

Main Product Image

Why Register?

  • View wholesale prices with discounts
  • Real-time stock availability
  • Access invoices and dispatch notes
  • Order history and frequently ordered items
  • Exclusive B2B offers

and much more...

Details

  • Low-voltage industrial components
  • Frequency converter =< 1 kV
  • 1 KOM
  • EATON

Technical specifications

Number of digital outputs

1

Depth

340.7mm

Height

888.5mm

Number of digital inputs

8

Power consumption

2024W

Width

288mm

Number of analogue inputs

2

With control element

Supporting protocol for LON

Number of HW-interfaces RS-422

0

Number of HW-interfaces RS-485

1

Number of HW-interfaces serial TTY

0

Number of HW-interfaces USB

0

Number of HW-interfaces industrial Ethernet

1

Number of HW-interfaces RS-232

0

Number of analogue outputs

2

Supporting protocol for PROFIBUS

Supporting protocol for INTERBUS

Supporting protocol for Data-Highway

Supporting protocol for TCP/IP

Supporting protocol for ASI

Number of HW-interfaces other

1

Number of HW-interfaces parallel

0

Degree of protection (IP)

IP21

Supporting protocol for Modbus

With optical interface

Supporting protocol for other bus systems

Supporting protocol for DeviceNet

Supporting protocol for KNX

Supporting protocol for CAN

Supporting protocol for SUCONET

Supporting protocol for INTERBUS-Safety

With PC connection

Supporting protocol for SERCOS

Mains voltage

380 .. 500V

Number of phases output

3

4-quadrant operation possible

Number of phases input

3

Mains frequency

50/60 Hz

Type of converter

U converter

Number of interfaces PROFINET

0

Relative symmetric net voltage tolerance

10%

Max. output frequency

400Hz

Application in industrial area permitted

Max. output at quadratic load at rated output voltage

110kW

Supporting protocol for DeviceNet Safety

Supporting protocol for PROFINET CBA

Application in domestic- and commercial area permitted

Supporting protocol for EtherNet/IP

Relative symmetric net frequency tolerance

10%

Max. output at linear load at rated output voltage

90kW

Supporting protocol for PROFIsafe

Integrated breaking resistance

Supporting protocol for Foundation Fieldbus

Supporting protocol for AS-Interface Safety at Work

Supporting protocol for PROFINET IO

Degree of protection (NEMA)

1

Supporting protocol for SafetyBUS p

Supporting protocol for BACnet

Nominal output current I2N

170A

Max. output voltage

500V

Related products

VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user.