  • Low-voltage industrial components
  • Frequency converter =< 1 kV
  • 1 KOM
  • EATON

Technical specifications

Depth340.7mm
With control elementYes
Width288mm
Number of digital outputs1
Height888.5mm
Number of digital inputs8
Power consumption2024W
Number of HW-interfaces industrial Ethernet1
Number of HW-interfaces serial TTY0
Number of HW-interfaces RS-4220
Number of analogue outputs2
Supporting protocol for PROFIBUSYes
With optical interfaceNo
Supporting protocol for TCP/IPYes
Number of HW-interfaces RS-2320
Supporting protocol for ASINo
Number of HW-interfaces other1
Number of analogue inputs2
Supporting protocol for LONNo
Number of HW-interfaces RS-4851
Number of HW-interfaces parallel0
With PC connectionYes
Supporting protocol for KNXNo
Supporting protocol for DeviceNetYes
Supporting protocol for other bus systemsYes
Supporting protocol for ModbusYes
Supporting protocol for INTERBUSNo
Supporting protocol for SUCONETNo
Degree of protection (IP)IP21
Supporting protocol for Data-HighwayNo
Supporting protocol for CANYes
Number of HW-interfaces USB0
Number of phases output3
Supporting protocol for INTERBUS-SafetyNo
Max. output at linear load at rated output voltage90kW
Type of converterU converter
Mains frequency50/60 Hz
Supporting protocol for SERCOSNo
Number of phases input3
Max. output at quadratic load at rated output voltage110kW
Relative symmetric net voltage tolerance10%
Supporting protocol for AS-Interface Safety at WorkNo
Mains voltage380 - 500V
Number of interfaces PROFINET0
Supporting protocol for EtherNet/IPYes
Supporting protocol for Foundation FieldbusNo
Integrated breaking resistanceNo
Relative symmetric net frequency tolerance10%
Supporting protocol for DeviceNet SafetyNo
4-quadrant operation possibleNo
Application in industrial area permittedYes
Max. output frequency400Hz
Application in domestic- and commercial area permittedYes
Supporting protocol for SafetyBUS pNo
Supporting protocol for PROFINET CBANo
Supporting protocol for PROFINET IOYes
Supporting protocol for PROFIsafeNo
Degree of protection (NEMA)1
Max. output voltage500V
Nominal output current I2N170A
Supporting protocol for BACnetYes

Related products

*VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user

DG1-34170FN-C21C

Main Product Image

Why Register?

  • View wholesale prices with discounts
  • Real-time stock availability
  • Access invoices and dispatch notes
  • Order history and frequently ordered items
  • Exclusive B2B offers

and much more...

Details

  • Low-voltage industrial components
  • Frequency converter =< 1 kV
  • 1 KOM
  • EATON

Technical specifications

Depth

340.7mm

With control element

Width

288mm

Number of digital outputs

1

Height

888.5mm

Number of digital inputs

8

Power consumption

2024W

Number of HW-interfaces industrial Ethernet

1

Number of HW-interfaces serial TTY

0

Number of HW-interfaces RS-422

0

Number of analogue outputs

2

Supporting protocol for PROFIBUS

With optical interface

Supporting protocol for TCP/IP

Number of HW-interfaces RS-232

0

Supporting protocol for ASI

Number of HW-interfaces other

1

Number of analogue inputs

2

Supporting protocol for LON

Number of HW-interfaces RS-485

1

Number of HW-interfaces parallel

0

With PC connection

Supporting protocol for KNX

Supporting protocol for DeviceNet

Supporting protocol for other bus systems

Supporting protocol for Modbus

Supporting protocol for INTERBUS

Supporting protocol for SUCONET

Degree of protection (IP)

IP21

Supporting protocol for Data-Highway

Supporting protocol for CAN

Number of HW-interfaces USB

0

Number of phases output

3

Supporting protocol for INTERBUS-Safety

Max. output at linear load at rated output voltage

90kW

Type of converter

U converter

Mains frequency

50/60 Hz

Supporting protocol for SERCOS

Number of phases input

3

Max. output at quadratic load at rated output voltage

110kW

Relative symmetric net voltage tolerance

10%

Supporting protocol for AS-Interface Safety at Work

Mains voltage

380 .. 500V

Number of interfaces PROFINET

0

Supporting protocol for EtherNet/IP

Supporting protocol for Foundation Fieldbus

Integrated breaking resistance

Relative symmetric net frequency tolerance

10%

Supporting protocol for DeviceNet Safety

4-quadrant operation possible

Application in industrial area permitted

Max. output frequency

400Hz

Application in domestic- and commercial area permitted

Supporting protocol for SafetyBUS p

Supporting protocol for PROFINET CBA

Supporting protocol for PROFINET IO

Supporting protocol for PROFIsafe

Degree of protection (NEMA)

1

Max. output voltage

500V

Nominal output current I2N

170A

Supporting protocol for BACnet