Aleta.hr

Details

  • Low-voltage industrial components
  • Frequency converter =< 1 kV
  • 1 KOM
  • EATON

Technical specifications

Height1538mm
Depth561mm
Width1037mm
Number of digital inputs8
Number of HW-interfaces industrial Ethernet1
Number of digital outputs1
Number of HW-interfaces serial TTY0
Supporting protocol for CANYes
Supporting protocol for LONNo
Number of analogue outputs2
Supporting protocol for ASINo
Supporting protocol for DeviceNetYes
With control elementYes
Number of HW-interfaces RS-4851
Supporting protocol for INTERBUSNo
Number of HW-interfaces parallel0
Supporting protocol for KNXNo
Supporting protocol for Data-HighwayNo
Number of HW-interfaces RS-4220
Number of HW-interfaces other1
Number of HW-interfaces USB0
Number of HW-interfaces RS-2320
Supporting protocol for ModbusYes
With optical interfaceNo
Supporting protocol for TCP/IPYes
Supporting protocol for SUCONETNo
Number of analogue inputs2
Supporting protocol for PROFIBUSYes
Degree of protection (IP)IP00
Supporting protocol for other bus systemsYes
With PC connectionYes
Max. output at linear load at rated output voltage500kW
Max. output frequency400Hz
Supporting protocol for SERCOSNo
Mains frequency50/60 Hz
Number of phases input3
Number of interfaces PROFINET0
Integrated breaking resistanceYes
Number of phases output3
Supporting protocol for INTERBUS-SafetyNo
Mains voltage380 - 500V
Application in industrial area permittedYes
Application in domestic- and commercial area permittedYes
Max. output at quadratic load at rated output voltage630kW
Type of converterU converter
4-quadrant operation possibleYes
Supporting protocol for EtherNet/IPYes
Supporting protocol for AS-Interface Safety at WorkNo
Supporting protocol for Foundation FieldbusNo
Relative symmetric net frequency tolerance10%
Supporting protocol for PROFINET CBANo
Supporting protocol for DeviceNet SafetyNo
Relative symmetric net voltage tolerance10%
Nominal output current I2N920A
Supporting protocol for PROFINET IOYes
Supporting protocol for PROFIsafeNo
Max. output voltage500V
Supporting protocol for SafetyBUS pNo
Degree of protection (NEMA)Other
Supporting protocol for BACnetYes

Related products

*VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user

DG1-341K0FB-C00C

Main Product Image

Why Register?

  • View wholesale prices with discounts
  • Real-time stock availability
  • Access invoices and dispatch notes
  • Order history and frequently ordered items
  • Exclusive B2B offers

and much more...

Details

  • Low-voltage industrial components
  • Frequency converter =< 1 kV
  • 1 KOM
  • EATON

Technical specifications

Height

1538mm

Depth

561mm

Width

1037mm

Number of digital inputs

8

Number of HW-interfaces industrial Ethernet

1

Number of digital outputs

1

Number of HW-interfaces serial TTY

0

Supporting protocol for CAN

Supporting protocol for LON

Number of analogue outputs

2

Supporting protocol for ASI

Supporting protocol for DeviceNet

With control element

Number of HW-interfaces RS-485

1

Supporting protocol for INTERBUS

Number of HW-interfaces parallel

0

Supporting protocol for KNX

Supporting protocol for Data-Highway

Number of HW-interfaces RS-422

0

Number of HW-interfaces other

1

Number of HW-interfaces USB

0

Number of HW-interfaces RS-232

0

Supporting protocol for Modbus

With optical interface

Supporting protocol for TCP/IP

Supporting protocol for SUCONET

Number of analogue inputs

2

Supporting protocol for PROFIBUS

Degree of protection (IP)

IP00

Supporting protocol for other bus systems

With PC connection

Max. output at linear load at rated output voltage

500kW

Max. output frequency

400Hz

Supporting protocol for SERCOS

Mains frequency

50/60 Hz

Number of phases input

3

Number of interfaces PROFINET

0

Integrated breaking resistance

Number of phases output

3

Supporting protocol for INTERBUS-Safety

Mains voltage

380 .. 500V

Application in industrial area permitted

Application in domestic- and commercial area permitted

Max. output at quadratic load at rated output voltage

630kW

Type of converter

U converter

4-quadrant operation possible

Supporting protocol for EtherNet/IP

Supporting protocol for AS-Interface Safety at Work

Supporting protocol for Foundation Fieldbus

Relative symmetric net frequency tolerance

10%

Supporting protocol for PROFINET CBA

Supporting protocol for DeviceNet Safety

Relative symmetric net voltage tolerance

10%

Nominal output current I2N

920A

Supporting protocol for PROFINET IO

Supporting protocol for PROFIsafe

Max. output voltage

500V

Supporting protocol for SafetyBUS p

Degree of protection (NEMA)

Other

Supporting protocol for BACnet

Related products