Aleta.hr

Details

  • Low-voltage industrial components
  • Frequency converter =< 1 kV
  • 1 KOM
  • EATON

Technical specifications

Height1035mm
Width486mm
Depth371mm
Power consumption2620W
Number of HW-interfaces parallel0
Number of digital inputs8
With control elementYes
Number of HW-interfaces other1
Number of digital outputs1
Number of HW-interfaces USB0
Supporting protocol for LONNo
With optical interfaceNo
Supporting protocol for PROFIBUSYes
Number of HW-interfaces RS-4220
Number of HW-interfaces RS-4851
Number of HW-interfaces RS-2320
Supporting protocol for ASINo
Number of HW-interfaces industrial Ethernet1
Number of HW-interfaces serial TTY0
Number of analogue inputs2
Number of analogue outputs2
Supporting protocol for TCP/IPYes
Supporting protocol for CANYes
Supporting protocol for SUCONETNo
Supporting protocol for Data-HighwayNo
Supporting protocol for ModbusYes
Supporting protocol for INTERBUSNo
Supporting protocol for DeviceNetYes
Supporting protocol for KNXNo
Mains voltage380 - 500V
Supporting protocol for SERCOSNo
Supporting protocol for INTERBUS-SafetyNo
Degree of protection (IP)IP54
Max. output frequency400Hz
Supporting protocol for other bus systemsYes
Application in domestic- and commercial area permittedYes
Number of phases output3
Number of phases input3
Mains frequency50/60 Hz
Integrated breaking resistanceYes
With PC connectionYes
Application in industrial area permittedYes
Number of interfaces PROFINET0
4-quadrant operation possibleYes
Type of converterU converter
Max. output at linear load at rated output voltage110kW
Relative symmetric net voltage tolerance10%
Supporting protocol for EtherNet/IPYes
Supporting protocol for DeviceNet SafetyNo
Relative symmetric net frequency tolerance10%
Max. output at quadratic load at rated output voltage132kW
Supporting protocol for Foundation FieldbusNo
Supporting protocol for PROFINET CBANo
Supporting protocol for AS-Interface Safety at WorkNo
Max. output voltage500V
Supporting protocol for PROFIsafeNo
Supporting protocol for SafetyBUS pNo
Supporting protocol for PROFINET IOYes
Nominal output current I2N205A
Supporting protocol for BACnetYes
Degree of protection (NEMA)12

Related products

*VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user

DG1-34205FB-C54C

Main Product Image

Why Register?

  • View wholesale prices with discounts
  • Real-time stock availability
  • Access invoices and dispatch notes
  • Order history and frequently ordered items
  • Exclusive B2B offers

and much more...

Details

  • Low-voltage industrial components
  • Frequency converter =< 1 kV
  • 1 KOM
  • EATON

Technical specifications

Height

1035mm

Width

486mm

Depth

371mm

Power consumption

2620W

Number of HW-interfaces parallel

0

Number of digital inputs

8

With control element

Number of HW-interfaces other

1

Number of digital outputs

1

Number of HW-interfaces USB

0

Supporting protocol for LON

With optical interface

Supporting protocol for PROFIBUS

Number of HW-interfaces RS-422

0

Number of HW-interfaces RS-485

1

Number of HW-interfaces RS-232

0

Supporting protocol for ASI

Number of HW-interfaces industrial Ethernet

1

Number of HW-interfaces serial TTY

0

Number of analogue inputs

2

Number of analogue outputs

2

Supporting protocol for TCP/IP

Supporting protocol for CAN

Supporting protocol for SUCONET

Supporting protocol for Data-Highway

Supporting protocol for Modbus

Supporting protocol for INTERBUS

Supporting protocol for DeviceNet

Supporting protocol for KNX

Mains voltage

380 .. 500V

Supporting protocol for SERCOS

Supporting protocol for INTERBUS-Safety

Degree of protection (IP)

IP54

Max. output frequency

400Hz

Supporting protocol for other bus systems

Application in domestic- and commercial area permitted

Number of phases output

3

Number of phases input

3

Mains frequency

50/60 Hz

Integrated breaking resistance

With PC connection

Application in industrial area permitted

Number of interfaces PROFINET

0

4-quadrant operation possible

Type of converter

U converter

Max. output at linear load at rated output voltage

110kW

Relative symmetric net voltage tolerance

10%

Supporting protocol for EtherNet/IP

Supporting protocol for DeviceNet Safety

Relative symmetric net frequency tolerance

10%

Max. output at quadratic load at rated output voltage

132kW

Supporting protocol for Foundation Fieldbus

Supporting protocol for PROFINET CBA

Supporting protocol for AS-Interface Safety at Work

Max. output voltage

500V

Supporting protocol for PROFIsafe

Supporting protocol for SafetyBUS p

Supporting protocol for PROFINET IO

Nominal output current I2N

205A

Supporting protocol for BACnet

Degree of protection (NEMA)

12

Related products

VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user.