Technical specifications

Height1035mm
Width486mm
Power consumption3280W
Depth371mm
Number of digital outputs1
Number of HW-interfaces RS-4851
Number of HW-interfaces USB0
Number of HW-interfaces other1
Supporting protocol for CANYes
With control elementYes
Number of analogue outputs2
Supporting protocol for ASINo
Number of digital inputs8
Supporting protocol for INTERBUSNo
Supporting protocol for ModbusYes
With optical interfaceNo
Number of HW-interfaces serial TTY0
Number of analogue inputs2
Number of HW-interfaces industrial Ethernet1
Supporting protocol for PROFIBUSYes
Supporting protocol for TCP/IPYes
Supporting protocol for KNXNo
Number of HW-interfaces RS-2320
Supporting protocol for Data-HighwayNo
Number of HW-interfaces parallel0
Number of HW-interfaces RS-4220
Supporting protocol for LONNo
Supporting protocol for SUCONETNo
Supporting protocol for DeviceNetYes
Type of converterU converter
Supporting protocol for other bus systemsYes
Degree of protection (IP)IP54
Mains voltage380 - 500V
Application in domestic- and commercial area permittedYes
Relative symmetric net voltage tolerance10%
Max. output frequency400Hz
Application in industrial area permittedYes
Integrated breaking resistanceNo
Max. output at linear load at rated output voltage132kW
Supporting protocol for SERCOSNo
With PC connectionYes
Mains frequency50/60 Hz
Max. output at quadratic load at rated output voltage160kW
Supporting protocol for DeviceNet SafetyNo
Supporting protocol for EtherNet/IPYes
Supporting protocol for INTERBUS-SafetyNo
4-quadrant operation possibleNo
Supporting protocol for AS-Interface Safety at WorkNo
Relative symmetric net frequency tolerance10%
Number of interfaces PROFINET0
Number of phases output3
Number of phases input3
Supporting protocol for Foundation FieldbusNo
Supporting protocol for PROFINET CBANo
Degree of protection (NEMA)12
Supporting protocol for PROFINET IOYes
Supporting protocol for PROFIsafeNo
Supporting protocol for BACnetYes
Max. output voltage500V
Supporting protocol for SafetyBUS pNo
Nominal output current I2N245A

Related products

*VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user

DG1-34245FN-C54C

Main Product Image

Why Register?

  • View wholesale prices with discounts
  • Real-time stock availability
  • Access invoices and dispatch notes
  • Order history and frequently ordered items
  • Exclusive B2B offers

and much more...

Details

  • Low-voltage industrial components
  • Frequency converter =< 1 kV
  • 1 KOM
  • EATON

Technical specifications

Height

1035mm

Width

486mm

Power consumption

3280W

Depth

371mm

Number of digital outputs

1

Number of HW-interfaces RS-485

1

Number of HW-interfaces USB

0

Number of HW-interfaces other

1

Supporting protocol for CAN

With control element

Number of analogue outputs

2

Supporting protocol for ASI

Number of digital inputs

8

Supporting protocol for INTERBUS

Supporting protocol for Modbus

With optical interface

Number of HW-interfaces serial TTY

0

Number of analogue inputs

2

Number of HW-interfaces industrial Ethernet

1

Supporting protocol for PROFIBUS

Supporting protocol for TCP/IP

Supporting protocol for KNX

Number of HW-interfaces RS-232

0

Supporting protocol for Data-Highway

Number of HW-interfaces parallel

0

Number of HW-interfaces RS-422

0

Supporting protocol for LON

Supporting protocol for SUCONET

Supporting protocol for DeviceNet

Type of converter

U converter

Supporting protocol for other bus systems

Degree of protection (IP)

IP54

Mains voltage

380 .. 500V

Application in domestic- and commercial area permitted

Relative symmetric net voltage tolerance

10%

Max. output frequency

400Hz

Application in industrial area permitted

Integrated breaking resistance

Max. output at linear load at rated output voltage

132kW

Supporting protocol for SERCOS

With PC connection

Mains frequency

50/60 Hz

Max. output at quadratic load at rated output voltage

160kW

Supporting protocol for DeviceNet Safety

Supporting protocol for EtherNet/IP

Supporting protocol for INTERBUS-Safety

4-quadrant operation possible

Supporting protocol for AS-Interface Safety at Work

Relative symmetric net frequency tolerance

10%

Number of interfaces PROFINET

0

Number of phases output

3

Number of phases input

3

Supporting protocol for Foundation Fieldbus

Supporting protocol for PROFINET CBA

Degree of protection (NEMA)

12

Supporting protocol for PROFINET IO

Supporting protocol for PROFIsafe

Supporting protocol for BACnet

Max. output voltage

500V

Supporting protocol for SafetyBUS p

Nominal output current I2N

245A