Aleta.hr

Details

  • Low-voltage industrial components
  • Frequency converter =< 1 kV
  • 1 KOM
  • EATON

Technical specifications

Height327mm
Depth200.9mm
Number of HW-interfaces industrial Ethernet1
Width153mm
With control elementYes
Number of analogue inputs2
Supporting protocol for LONNo
Number of digital inputs8
Number of digital outputs1
Power consumption59W
Number of analogue outputs2
Supporting protocol for CANYes
Number of HW-interfaces other1
Number of HW-interfaces USB0
With optical interfaceNo
Supporting protocol for ASINo
Supporting protocol for TCP/IPYes
Supporting protocol for PROFIBUSYes
Number of HW-interfaces RS-4220
Number of HW-interfaces RS-4851
Number of HW-interfaces parallel0
Number of HW-interfaces RS-2320
Number of HW-interfaces serial TTY0
Supporting protocol for INTERBUSNo
Supporting protocol for ModbusYes
Mains voltage380 - 500V
Supporting protocol for DeviceNetYes
Supporting protocol for Data-HighwayNo
Supporting protocol for KNXNo
With PC connectionYes
Supporting protocol for INTERBUS-SafetyNo
Mains frequency50/60 Hz
Degree of protection (IP)IP54
Supporting protocol for other bus systemsYes
Supporting protocol for SUCONETNo
Supporting protocol for SERCOSNo
Integrated breaking resistanceYes
Number of interfaces PROFINET0
Application in domestic- and commercial area permittedYes
Application in industrial area permittedYes
4-quadrant operation possibleYes
Number of phases input3
Number of phases output3
Max. output frequency400Hz
Max. output at linear load at rated output voltage0.75kW
Type of converterU converter
Max. output at quadratic load at rated output voltage1.1kW
Relative symmetric net frequency tolerance10%
Supporting protocol for BACnetYes
Supporting protocol for EtherNet/IPYes
Degree of protection (NEMA)12
Supporting protocol for AS-Interface Safety at WorkNo
Supporting protocol for PROFIsafeNo
Nominal output current I2N2.2A
Supporting protocol for PROFINET IOYes
Supporting protocol for PROFINET CBANo
Supporting protocol for Foundation FieldbusNo
Max. output voltage500V
Supporting protocol for SafetyBUS pNo
Relative symmetric net voltage tolerance10%
Supporting protocol for DeviceNet SafetyNo

Related products

*VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user

DG1-342D2FB-C54C

Main Product Image

Why Register?

  • View wholesale prices with discounts
  • Real-time stock availability
  • Access invoices and dispatch notes
  • Order history and frequently ordered items
  • Exclusive B2B offers

and much more...

Details

  • Low-voltage industrial components
  • Frequency converter =< 1 kV
  • 1 KOM
  • EATON

Technical specifications

Height

327mm

Depth

200.9mm

Number of HW-interfaces industrial Ethernet

1

Width

153mm

With control element

Number of analogue inputs

2

Supporting protocol for LON

Number of digital inputs

8

Number of digital outputs

1

Power consumption

59W

Number of analogue outputs

2

Supporting protocol for CAN

Number of HW-interfaces other

1

Number of HW-interfaces USB

0

With optical interface

Supporting protocol for ASI

Supporting protocol for TCP/IP

Supporting protocol for PROFIBUS

Number of HW-interfaces RS-422

0

Number of HW-interfaces RS-485

1

Number of HW-interfaces parallel

0

Number of HW-interfaces RS-232

0

Number of HW-interfaces serial TTY

0

Supporting protocol for INTERBUS

Supporting protocol for Modbus

Mains voltage

380 .. 500V

Supporting protocol for DeviceNet

Supporting protocol for Data-Highway

Supporting protocol for KNX

With PC connection

Supporting protocol for INTERBUS-Safety

Mains frequency

50/60 Hz

Degree of protection (IP)

IP54

Supporting protocol for other bus systems

Supporting protocol for SUCONET

Supporting protocol for SERCOS

Integrated breaking resistance

Number of interfaces PROFINET

0

Application in domestic- and commercial area permitted

Application in industrial area permitted

4-quadrant operation possible

Number of phases input

3

Number of phases output

3

Max. output frequency

400Hz

Max. output at linear load at rated output voltage

0.75kW

Type of converter

U converter

Max. output at quadratic load at rated output voltage

1.1kW

Relative symmetric net frequency tolerance

10%

Supporting protocol for BACnet

Supporting protocol for EtherNet/IP

Degree of protection (NEMA)

12

Supporting protocol for AS-Interface Safety at Work

Supporting protocol for PROFIsafe

Nominal output current I2N

2.2A

Supporting protocol for PROFINET IO

Supporting protocol for PROFINET CBA

Supporting protocol for Foundation Fieldbus

Max. output voltage

500V

Supporting protocol for SafetyBUS p

Relative symmetric net voltage tolerance

10%

Supporting protocol for DeviceNet Safety

Related products