Number of digital outputs1
With control elementYes
Height1538mm
Number of HW-interfaces RS-2320
Depth561mm
Number of analogue inputs2
Number of analogue outputs2
Number of HW-interfaces industrial Ethernet1
Supporting protocol for LONNo
Number of digital inputs8
Width506mm
Number of HW-interfaces other1
Number of HW-interfaces RS-4220
Number of HW-interfaces parallel0
Number of HW-interfaces RS-4851
Number of HW-interfaces USB0
Number of HW-interfaces serial TTY0
Supporting protocol for TCP/IPYes
Supporting protocol for INTERBUSNo
Supporting protocol for INTERBUS-SafetyNo
Supporting protocol for KNXNo
Supporting protocol for DeviceNetYes
Degree of protection (IP)IP00
Supporting protocol for SERCOSNo
Supporting protocol for SUCONETNo
Supporting protocol for other bus systemsYes
Supporting protocol for CANYes
Supporting protocol for Data-HighwayNo
Supporting protocol for PROFIBUSYes
Supporting protocol for ModbusYes
Supporting protocol for ASINo
With optical interfaceNo
With PC connectionYes
Application in industrial area permittedYes
Integrated breaking resistanceYes
Number of phases output3
Mains voltage380 - 500V
Number of interfaces PROFINET0
Number of phases input3
Mains frequency50/60 Hz
Type of converterU converter
4-quadrant operation possibleYes
Supporting protocol for EtherNet/IPYes
Max. output at linear load at rated output voltage160kW
Application in domestic- and commercial area permittedYes
Supporting protocol for DeviceNet SafetyNo
Max. output at quadratic load at rated output voltage200kW
Relative symmetric net voltage tolerance10%
Supporting protocol for PROFIsafeNo
Supporting protocol for Foundation FieldbusNo
Supporting protocol for AS-Interface Safety at WorkNo
Degree of protection (NEMA)Other
Max. output frequency400Hz
Nominal output current I2N310A
Relative symmetric net frequency tolerance10%
Supporting protocol for BACnetYes
Supporting protocol for PROFINET IOYes
Max. output voltage500V
Supporting protocol for SafetyBUS pNo
Supporting protocol for PROFINET CBANo

Related products

*VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user

DG1-34310FB-C00C

Main Product Image

Why Register?

  • View wholesale prices with discounts
  • Real-time stock availability
  • Access invoices and dispatch notes
  • Order history and frequently ordered items
  • Exclusive B2B offers

and much more...

Details

  • Low-voltage industrial components
  • Frequency converter =< 1 kV
  • 1 KOM
  • EATON

Technical specifications

Number of digital outputs

1

With control element

Height

1538mm

Number of HW-interfaces RS-232

0

Depth

561mm

Number of analogue inputs

2

Number of analogue outputs

2

Number of HW-interfaces industrial Ethernet

1

Supporting protocol for LON

Number of digital inputs

8

Width

506mm

Number of HW-interfaces other

1

Number of HW-interfaces RS-422

0

Number of HW-interfaces parallel

0

Number of HW-interfaces RS-485

1

Number of HW-interfaces USB

0

Number of HW-interfaces serial TTY

0

Supporting protocol for TCP/IP

Supporting protocol for INTERBUS

Supporting protocol for INTERBUS-Safety

Supporting protocol for KNX

Supporting protocol for DeviceNet

Degree of protection (IP)

IP00

Supporting protocol for SERCOS

Supporting protocol for SUCONET

Supporting protocol for other bus systems

Supporting protocol for CAN

Supporting protocol for Data-Highway

Supporting protocol for PROFIBUS

Supporting protocol for Modbus

Supporting protocol for ASI

With optical interface

With PC connection

Application in industrial area permitted

Integrated breaking resistance

Number of phases output

3

Mains voltage

380 .. 500V

Number of interfaces PROFINET

0

Number of phases input

3

Mains frequency

50/60 Hz

Type of converter

U converter

4-quadrant operation possible

Supporting protocol for EtherNet/IP

Max. output at linear load at rated output voltage

160kW

Application in domestic- and commercial area permitted

Supporting protocol for DeviceNet Safety

Max. output at quadratic load at rated output voltage

200kW

Relative symmetric net voltage tolerance

10%

Supporting protocol for PROFIsafe

Supporting protocol for Foundation Fieldbus

Supporting protocol for AS-Interface Safety at Work

Degree of protection (NEMA)

Other

Max. output frequency

400Hz

Nominal output current I2N

310A

Relative symmetric net frequency tolerance

10%

Supporting protocol for BACnet

Supporting protocol for PROFINET IO

Max. output voltage

500V

Supporting protocol for SafetyBUS p

Supporting protocol for PROFINET CBA