Technical specifications

Depth561mm
With control elementYes
Height1538mm
Width506mm
Number of HW-interfaces industrial Ethernet1
Supporting protocol for CANYes
Number of analogue inputs2
Number of HW-interfaces other1
Supporting protocol for ASINo
Number of analogue outputs2
Number of HW-interfaces RS-2320
Number of digital outputs1
Supporting protocol for INTERBUSNo
Number of HW-interfaces RS-4851
Supporting protocol for TCP/IPYes
Number of HW-interfaces parallel0
Number of HW-interfaces RS-4220
With optical interfaceNo
Supporting protocol for KNXNo
Supporting protocol for PROFIBUSYes
Number of HW-interfaces USB0
Supporting protocol for LONNo
Number of HW-interfaces serial TTY0
Number of digital inputs8
Supporting protocol for Data-HighwayNo
Supporting protocol for DeviceNetYes
Supporting protocol for other bus systemsYes
Supporting protocol for ModbusYes
Supporting protocol for SUCONETNo
4-quadrant operation possibleYes
Mains voltage380 - 500V
Supporting protocol for DeviceNet SafetyNo
Supporting protocol for SERCOSNo
With PC connectionYes
Supporting protocol for EtherNet/IPYes
Max. output at quadratic load at rated output voltage250kW
Max. output frequency400Hz
Application in domestic- and commercial area permittedYes
Max. output at linear load at rated output voltage200kW
Relative symmetric net voltage tolerance10%
Mains frequency50/60 Hz
Integrated breaking resistanceYes
Number of phases output3
Supporting protocol for INTERBUS-SafetyNo
Relative symmetric net frequency tolerance10%
Degree of protection (IP)IP00
Type of converterU converter
Application in industrial area permittedYes
Number of phases input3
Number of interfaces PROFINET0
Supporting protocol for PROFINET IOYes
Supporting protocol for PROFINET CBANo
Supporting protocol for Foundation FieldbusNo
Supporting protocol for AS-Interface Safety at WorkNo
Supporting protocol for PROFIsafeNo
Supporting protocol for BACnetYes
Nominal output current I2N385A
Degree of protection (NEMA)Other
Supporting protocol for SafetyBUS pNo
Max. output voltage500V

Related products

*VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user

DG1-34385FB-C00C

Main Product Image

Why Register?

  • View wholesale prices with discounts
  • Real-time stock availability
  • Access invoices and dispatch notes
  • Order history and frequently ordered items
  • Exclusive B2B offers

and much more...

Details

  • Low-voltage industrial components
  • Frequency converter =< 1 kV
  • 1 KOM
  • EATON

Technical specifications

Depth

561mm

With control element

Height

1538mm

Width

506mm

Number of HW-interfaces industrial Ethernet

1

Supporting protocol for CAN

Number of analogue inputs

2

Number of HW-interfaces other

1

Supporting protocol for ASI

Number of analogue outputs

2

Number of HW-interfaces RS-232

0

Number of digital outputs

1

Supporting protocol for INTERBUS

Number of HW-interfaces RS-485

1

Supporting protocol for TCP/IP

Number of HW-interfaces parallel

0

Number of HW-interfaces RS-422

0

With optical interface

Supporting protocol for KNX

Supporting protocol for PROFIBUS

Number of HW-interfaces USB

0

Supporting protocol for LON

Number of HW-interfaces serial TTY

0

Number of digital inputs

8

Supporting protocol for Data-Highway

Supporting protocol for DeviceNet

Supporting protocol for other bus systems

Supporting protocol for Modbus

Supporting protocol for SUCONET

4-quadrant operation possible

Mains voltage

380 .. 500V

Supporting protocol for DeviceNet Safety

Supporting protocol for SERCOS

With PC connection

Supporting protocol for EtherNet/IP

Max. output at quadratic load at rated output voltage

250kW

Max. output frequency

400Hz

Application in domestic- and commercial area permitted

Max. output at linear load at rated output voltage

200kW

Relative symmetric net voltage tolerance

10%

Mains frequency

50/60 Hz

Integrated breaking resistance

Number of phases output

3

Supporting protocol for INTERBUS-Safety

Relative symmetric net frequency tolerance

10%

Degree of protection (IP)

IP00

Type of converter

U converter

Application in industrial area permitted

Number of phases input

3

Number of interfaces PROFINET

0

Supporting protocol for PROFINET IO

Supporting protocol for PROFINET CBA

Supporting protocol for Foundation Fieldbus

Supporting protocol for AS-Interface Safety at Work

Supporting protocol for PROFIsafe

Supporting protocol for BACnet

Nominal output current I2N

385A

Degree of protection (NEMA)

Other

Supporting protocol for SafetyBUS p

Max. output voltage

500V