Aleta.hr

Details

  • Low-voltage industrial components
  • Frequency converter =< 1 kV
  • 1 KOM
  • EATON

Technical specifications

Depth200.9mm
Height327mm
Width153mm
With control elementYes
Power consumption73W
Number of HW-interfaces other1
Number of analogue outputs2
Number of HW-interfaces industrial Ethernet1
Number of HW-interfaces serial TTY0
Number of HW-interfaces RS-2320
Number of digital outputs1
Number of HW-interfaces USB0
Number of digital inputs8
Number of HW-interfaces parallel0
Supporting protocol for ASINo
Supporting protocol for LONNo
With optical interfaceNo
Supporting protocol for INTERBUSNo
Supporting protocol for PROFIBUSYes
Number of analogue inputs2
Number of HW-interfaces RS-4851
Supporting protocol for TCP/IPYes
Supporting protocol for CANYes
Supporting protocol for KNXNo
Supporting protocol for ModbusYes
Number of HW-interfaces RS-4220
Supporting protocol for Data-HighwayNo
Supporting protocol for DeviceNetYes
Supporting protocol for other bus systemsYes
Supporting protocol for SUCONETNo
Number of phases output3
Type of converterU converter
Degree of protection (IP)IP54
Max. output frequency400Hz
Mains voltage380 - 500V
4-quadrant operation possibleYes
Relative symmetric net voltage tolerance10%
Max. output at linear load at rated output voltage1.1kW
Application in domestic- and commercial area permittedYes
Max. output at quadratic load at rated output voltage1.5kW
Integrated breaking resistanceYes
Application in industrial area permittedYes
Number of interfaces PROFINET0
Supporting protocol for INTERBUS-SafetyNo
Mains frequency50/60 Hz
Number of phases input3
With PC connectionYes
Supporting protocol for SERCOSNo
Relative symmetric net frequency tolerance10%
Supporting protocol for PROFINET CBANo
Supporting protocol for EtherNet/IPYes
Supporting protocol for PROFINET IOYes
Supporting protocol for Foundation FieldbusNo
Supporting protocol for DeviceNet SafetyNo
Supporting protocol for AS-Interface Safety at WorkNo
Degree of protection (NEMA)12
Supporting protocol for PROFIsafeNo
Max. output voltage500V
Supporting protocol for SafetyBUS pNo
Nominal output current I2N3.3A
Supporting protocol for BACnetYes

Related products

*VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user

DG1-343D3FB-C54C

Main Product Image

Why Register?

  • View wholesale prices with discounts
  • Real-time stock availability
  • Access invoices and dispatch notes
  • Order history and frequently ordered items
  • Exclusive B2B offers

and much more...

Details

  • Low-voltage industrial components
  • Frequency converter =< 1 kV
  • 1 KOM
  • EATON

Technical specifications

Depth

200.9mm

Height

327mm

Width

153mm

With control element

Power consumption

73W

Number of HW-interfaces other

1

Number of analogue outputs

2

Number of HW-interfaces industrial Ethernet

1

Number of HW-interfaces serial TTY

0

Number of HW-interfaces RS-232

0

Number of digital outputs

1

Number of HW-interfaces USB

0

Number of digital inputs

8

Number of HW-interfaces parallel

0

Supporting protocol for ASI

Supporting protocol for LON

With optical interface

Supporting protocol for INTERBUS

Supporting protocol for PROFIBUS

Number of analogue inputs

2

Number of HW-interfaces RS-485

1

Supporting protocol for TCP/IP

Supporting protocol for CAN

Supporting protocol for KNX

Supporting protocol for Modbus

Number of HW-interfaces RS-422

0

Supporting protocol for Data-Highway

Supporting protocol for DeviceNet

Supporting protocol for other bus systems

Supporting protocol for SUCONET

Number of phases output

3

Type of converter

U converter

Degree of protection (IP)

IP54

Max. output frequency

400Hz

Mains voltage

380 .. 500V

4-quadrant operation possible

Relative symmetric net voltage tolerance

10%

Max. output at linear load at rated output voltage

1.1kW

Application in domestic- and commercial area permitted

Max. output at quadratic load at rated output voltage

1.5kW

Integrated breaking resistance

Application in industrial area permitted

Number of interfaces PROFINET

0

Supporting protocol for INTERBUS-Safety

Mains frequency

50/60 Hz

Number of phases input

3

With PC connection

Supporting protocol for SERCOS

Relative symmetric net frequency tolerance

10%

Supporting protocol for PROFINET CBA

Supporting protocol for EtherNet/IP

Supporting protocol for PROFINET IO

Supporting protocol for Foundation Fieldbus

Supporting protocol for DeviceNet Safety

Supporting protocol for AS-Interface Safety at Work

Degree of protection (NEMA)

12

Supporting protocol for PROFIsafe

Max. output voltage

500V

Supporting protocol for SafetyBUS p

Nominal output current I2N

3.3A

Supporting protocol for BACnet