Aleta.hr

Details

  • Low-voltage industrial components
  • Frequency converter =< 1 kV
  • 1 KOM
  • EATON

Technical specifications

Number of analogue inputs2
With control elementYes
Number of HW-interfaces RS-4220
Supporting protocol for LONNo
Number of analogue outputs2
Depth561mm
Number of HW-interfaces RS-4851
Number of HW-interfaces industrial Ethernet1
Number of digital outputs1
Number of HW-interfaces RS-2320
Height1538mm
Width506mm
Number of digital inputs8
Supporting protocol for TCP/IPYes
Number of HW-interfaces other1
Number of HW-interfaces parallel0
With optical interfaceNo
Number of HW-interfaces serial TTY0
Number of HW-interfaces USB0
Supporting protocol for other bus systemsYes
Number of phases input3
Supporting protocol for Data-HighwayNo
Supporting protocol for ASINo
Supporting protocol for PROFIBUSYes
Type of converterU converter
Supporting protocol for SUCONETNo
Supporting protocol for ModbusYes
Supporting protocol for CANYes
Supporting protocol for DeviceNetYes
Number of interfaces PROFINET0
Mains voltage380 - 500V
4-quadrant operation possibleYes
Mains frequency50/60 Hz
With PC connectionYes
Supporting protocol for SERCOSNo
Degree of protection (IP)IP00
Number of phases output3
Supporting protocol for INTERBUS-SafetyNo
Supporting protocol for INTERBUSNo
Application in domestic- and commercial area permittedYes
Max. output frequency400Hz
Integrated breaking resistanceYes
Application in industrial area permittedYes
Supporting protocol for KNXNo
Supporting protocol for PROFIsafeNo
Max. output at linear load at rated output voltage250kW
Relative symmetric net frequency tolerance10%
Max. output voltage500V
Supporting protocol for PROFINET CBANo
Supporting protocol for SafetyBUS pNo
Supporting protocol for Foundation FieldbusNo
Degree of protection (NEMA)Other
Max. output at quadratic load at rated output voltage315kW
Relative symmetric net voltage tolerance10%
Supporting protocol for BACnetYes
Supporting protocol for PROFINET IOYes
Supporting protocol for EtherNet/IPYes
Supporting protocol for DeviceNet SafetyNo
Supporting protocol for AS-Interface Safety at WorkNo
Nominal output current I2N520A

Related products

*VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user

DG1-34520FB-C00C

Main Product Image

Why Register?

  • View wholesale prices with discounts
  • Real-time stock availability
  • Access invoices and dispatch notes
  • Order history and frequently ordered items
  • Exclusive B2B offers

and much more...

Details

  • Low-voltage industrial components
  • Frequency converter =< 1 kV
  • 1 KOM
  • EATON

Technical specifications

Number of analogue inputs

2

With control element

Number of HW-interfaces RS-422

0

Supporting protocol for LON

Number of analogue outputs

2

Depth

561mm

Number of HW-interfaces RS-485

1

Number of HW-interfaces industrial Ethernet

1

Number of digital outputs

1

Number of HW-interfaces RS-232

0

Height

1538mm

Width

506mm

Number of digital inputs

8

Supporting protocol for TCP/IP

Number of HW-interfaces other

1

Number of HW-interfaces parallel

0

With optical interface

Number of HW-interfaces serial TTY

0

Number of HW-interfaces USB

0

Supporting protocol for other bus systems

Number of phases input

3

Supporting protocol for Data-Highway

Supporting protocol for ASI

Supporting protocol for PROFIBUS

Type of converter

U converter

Supporting protocol for SUCONET

Supporting protocol for Modbus

Supporting protocol for CAN

Supporting protocol for DeviceNet

Number of interfaces PROFINET

0

Mains voltage

380 .. 500V

4-quadrant operation possible

Mains frequency

50/60 Hz

With PC connection

Supporting protocol for SERCOS

Degree of protection (IP)

IP00

Number of phases output

3

Supporting protocol for INTERBUS-Safety

Supporting protocol for INTERBUS

Application in domestic- and commercial area permitted

Max. output frequency

400Hz

Integrated breaking resistance

Application in industrial area permitted

Supporting protocol for KNX

Supporting protocol for PROFIsafe

Max. output at linear load at rated output voltage

250kW

Relative symmetric net frequency tolerance

10%

Max. output voltage

500V

Supporting protocol for PROFINET CBA

Supporting protocol for SafetyBUS p

Supporting protocol for Foundation Fieldbus

Degree of protection (NEMA)

Other

Max. output at quadratic load at rated output voltage

315kW

Relative symmetric net voltage tolerance

10%

Supporting protocol for BACnet

Supporting protocol for PROFINET IO

Supporting protocol for EtherNet/IP

Supporting protocol for DeviceNet Safety

Supporting protocol for AS-Interface Safety at Work

Nominal output current I2N

520A

Related products

VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user.